Details of AC032S \ ecomat 300 \ AS-i (Safety Enhancing Device for AS-interface system) enhan. net \ DE
AC032S \ ecomat 300 \ AS-i (Safety Enhancing Device for AS-interface system) enhan. net \ DE is a tool for safely monitoring protection systems that can be used with various AS-interface devices
Technical Data AC032S \ ecomat 300 \ AS-i (Safety Enhancing Device for AS-interface system) enhan. net \ DE
Electrical design 1 safety-related output
Operating voltage [V] 24 DC ± 15%
Current consumption [mA]< 45
Peak switch-on current **) [mA] 600
Overvoltage category 3, for rated operating voltage 300 V AC to VDE 0110 part 1
Rated operating current [mA] 250
Input current High/Low [mA] 10 (24 V DC) / -
start input: optocoupler input (high active), input current approx. 10 mA (24 V DC)
contactor control input (EDM): optocoupler input (high active), input current approx. 10 mA (24 V DC)
Message output Safety ON ***) PNP transistor output/ 200 mA / reverse polarity and short-circuit protection
Safety output 2 volt-free NO contacts
max. contact load: 1 A DC-13 (24 V DC) / 3 A AC-15 (230 V AC)
continuous thermal current: 3 A per output circuit
Configuration interface 9600 baud / no parity / 1 start bit / 1 stop bit / 8 data bits
We use cookies to make the site work properly, to understand how it is used, and to show content that is relevant to you. You choose which types to allow; strictly necessary cookies are always on. Privacy Policy