Details of LMT302 \ efector 160 \ Level sensor (Level Sensor) \LMCCE-A01E-QSKG-2/US \ DE
LMT302 \ efector 160 \ Level sensor (Level Sensor) \LMCCE-A01E-QSKG-2/US \ DE Point level sensor, adjustable for various media contact applications.
Easy to set up via IO-Link system
Can be used for both food industry and general purpose liquid level measurement
Suitable for powders, liquids, and viscous media
Adjustable through I/O Link to detect only the actual medium without detecting bubbles or residues on the sensor
Housing made of stainless steel 316L, food contact material made from PEEK for maximum cleanliness
Mounted with G½A, G¾A, and G1A threads
Operating voltage: 18...30 VDC
Size M30x113-355 mm.
Dustproof and waterproof standard IP68/IP69K
The LMT302 \ efector 160 \ Level sensor (Level Sensor) \LMCCE-A01E-QSKG-2/US \ DE is used to measure liquid levels in tanks, such as bottled water plants, powdered milk production, or for measuring levels in tanks with high foam content like beer and yogurt factories, and also measures the level of viscous media like chili sauce factories.
Technical Data LMT302 \ efector 160 \ Level sensor (Level Sensor) \LMCCE-A01E-QSKG-2/US \ DE
Number of inputs and outputs : Number of digital outputs: 2
Factory setting : hydrous media
Process connection : G 1 external thread
Special feature : Gold-plated contacts
Installation : suitable for installation in existing tuning fork adapters
Media : Liquids; viscous media; powder
Recommended media : water; hydrous media; oils; oil-based media; powder
Cannot be used for : See the operating instructions, chapter "Function and features".