SUPMEA FLC240-50G1M1TGNT1R1WG Turbine Flowmeter Size DN50 (2 inch)
SUPMEA FLC240-50G1M1TGNT1R1WG Turbine Flowmeter is a liquid turbine flowmeter used to measure the volumetric flow rate of liquids within closed pipe systems. It operates on the principle that the rotational speed of the turbine rotor (Turbine Rotor) is proportional to the fluid's flow rate.
This model has a size of DN50 (2 inches), supports RS485 communication, and features a display for reading measurement values directly from the meter. It can also be connected to monitoring or industrial control systems that support such communication protocols.
The FLC240 series is suitable for measuring low-viscosity liquids, with consideration given to fluid properties and installation conditions as specified by the manufacturer.
General Features
- Product Model: FLC240-50G1M1TGNT1R1WG
- Brand: SUPMEA
- Product Type: Turbine Flowmeter
- Product Series: FLC240
- Measurement Principle: Turbine Flow Measurement
- Pipe Size: DN50 (2 inches)
- Supports RS485 Communication
- Features a Display
- Adequate for measuring the flow rate of liquids suitable for turbine meters
Technical Specifications
| Model |
FLC240-50G1M1TGNT1R1WG |
| Brand |
SUPMEA |
| Product Series |
FLC240 |
| Product Type |
Turbine Flowmeter |
| Nominal Size |
DN50 (2") |
| Measurement Principle |
Turbine |
| Communication |
RS485 |
| Display |
Display |
Principle of Operation
The turbine flowmeter uses a rotor (Turbine Rotor) installed within the flow path. As liquid passes through the meter, it causes the rotor to spin. The rotational speed of the rotor is proportional to the fluid's flow rate. A sensor detects this rotation and sends data to processing circuits for measurement calculation.
The FLC240-50G1M1TGNT1R1WG model can read measurement data through the device's display screen and uses RS485 communication for connecting data with compatible control devices or systems.
Size and Installation
The FLC240-50G1M1TGNT1R1WG is a DN50 (2-inch) flow meter. Before installation, check the fitting type, actual connection size, and installation standards to match the pipe system, including the direction of flow and straight pipe lengths before and after the meter as per manufacturer specifications.
Check the fluid type and viscosity before use. The FLC240 series is suitable for low-viscosity fluids without fibers or solid particles that may interfere with propeller operation.
Examples and Usage Guidelines
- Monitor the flow rate of low-viscosity liquids in a closed pipe system.
- Apply in cooling water systems and liquid circulation systems under suitable conditions.
- Use to monitor flow rates during industrial production processes.
- Read measurement data from the device's display screen.
- Connect data via RS485 with PLC, HMI or compatible monitoring systems.
Considerations
- The FLC240-50G1M1TGNT1R1WG model supports RS485 communication and has a display screen.
- Do not assume this model includes 4-20mA Two-wire signal or Pulse Output as these are other options in the FLC240 series.
- Check Modbus RS485 settings such as Address, Baud Rate, and data format according to the manufacturer's manual.
- Verify the flow rate range and accuracy specific to the DN50 model before selecting for use.
- Ensure fluid type, viscosity, temperature, and operating pressure meet manufacturer specifications.
- Check connection types and fitting sizes before actual installation.
- Review power supply voltage and wiring details from the specific model documentation.
- Verify flow direction and straight pipe lengths according to installation requirements.