SUPMEA FLC240-15B0M1TGNT1K0WF Turbine Flowmeter Size DN15 (1/2 inch)
SUPMEA FLC240-15B0M1TGNT1K0WF Turbine Flowmeter is a liquid turbine flowmeter that uses the principle of rotating turbine blades within the flow path. The rotational speed of the turbine blades is directly proportional to the fluid flow rate.
This model has a size of DN15 (1/2 inch) and supports Pulse output signal without display, suitable for connecting with pulse signal receiving devices or systems that support flow rate monitoring.
The FLC240 series is designed for volumetric flow measurement of low-viscosity liquids in closed pipe systems. The appropriate operating conditions must be selected according to the meter specifications.
General Features
- Product Model: FLC240-15B0M1TGNT1K0WF
- Brand: SUPMEA
- Product Type: Turbine Flowmeter
- Product Series: FLC240
- Measurement Principle: Turbine Flow Measurement
- Pipe Size: DN15 (1/2 inch)
- Signal Output: Pulse Output
- Display: No Display
- Suitable for measuring fluid flow rates that are appropriate for turbine measurement principle.
Technical Specifications
| Model |
FLC240-15B0M1TGNT1K0WF |
| Brand |
SUPMEA |
| Product Series |
FLC240 |
| Product Type |
Turbine Flowmeter |
| Nominal Size |
DN15 (1/2") |
| Measurement Principle |
Turbine |
| Signal Output |
Pulse |
| Display |
No Display |
Operating Principle
The turbine flowmeter uses a turbine rotor inside the meter. When fluid flows through, it causes the rotor to spin. The rotational speed of the rotor is directly proportional to the flow rate. A sensor detects the rotation and generates pulse signals which can be processed into flow rate or volume measurements using appropriate receiving devices.
Model FLC240-15B0M1TGNT1K0WF does not have a display screen, so an external device that supports Pulse signal must be used to read or process the measurement values.
Size and Installation
This flow meter model has a DN15 (1/2 inch) size. Before installation, check the type of fitting, actual connection size, direction of flow, and straight pipe lengths before and after the meter according to the manufacturer's manual.
Consider the properties of the liquid, viscosity, and contaminants in the pipeline system to ensure suitability for measurement with turbine technology.
Examples and Usage Guidelines
- Check the flow rate of low-viscosity liquids in a closed pipe system.
- Apply in water systems or fluid circulation systems under suitable conditions.
- Send Pulse signals to PLCs or compatible signal receivers.
- Use with pulse counters for processing flow volume.
- Apply in production process flow rate monitoring systems.
Considerations
- The FLC240-15B0M1TGNT1K0WF model is a Pulse Output model and does not have a display screen.
- Do not assume that this model supports 4-20mA or RS485 as these are options for other models in the FLC240 series.
- Check the flow rate range and accuracy of the DN15 model before selecting it for use.
- Verify the type of liquid, viscosity, temperature, and operating pressure to meet manufacturer specifications.
- Check the power supply voltage, Pulse signal level, and K-Factor of the meter before connecting to a signal receiving system.
- Check the fitting type and connection size from the specific model technical documentation before installation.
- Avoid using with liquids containing contaminants or solid particles unless approved for suitability by the manufacturer.