SANGI ELECTRIC SG-VB-4T250/280P, SG-VB-4T250/280P Inverter, SG-VB-4T250G/280P, SANGI SG-VB Series, Industrial Inverter, Variable Frequency Drive, VFD, AC Motor Drive, Three Phase Motor Inverter, Three Phase 380VAC Inverter, 250kW G Type Inverter, 280kW P Type Inverter, 250kW 280kW VFD, Heavy Duty Inverter, Normal Duty Inverter, High Power Inverter, Variable Speed Drive, V/F Control, Torque Control, RS485 Modbus Inverter, Industrial Motor Speed Control, Three Phase AC Motor Control, Industrial Automation Drive, Pump Inverter, Fan Inverter, HVAC Motor Drive, AHU Inverter, Conveyor Drive, Industrial Motor Controller, Factory Automation, Process Control, SANGI ELECTRIC Inverter Thailand, Inverter SANGI ELECTRIC, SG-VB Inverter, 3-Phase Inverter, 380VAC Inverter, 250kW Inverter, 280kW Inverter, High Power Inverter, Variable Speed Motor Control Inverter, V/F Control Inverter, Pump Inverter, Fan Inverter, Conveyor Drive Inverter, Industrial Motor Controller, RS485 Modbus Inverter, Automatic Motor Control System, SANGI SG-VB-4T250/280P Thailand

*Price does not include VAT

SANGI ELECTRIC Inverter Model SG-VB-4T250/280P (Industrial Variable Frequency Drive)

SANGI ELECTRIC SG-VB-4T250/280P is an inverter or Variable Frequency Drive (VFD) from the SG-VB Series designed to control the speed of three-phase AC motors by adjusting the output frequency and voltage according to the motor's operational characteristics and industrial machinery requirements.

The code SG-VB-4T250/280P is similar to the base model VB-4T250G/280P, which has a power rating of 250 kW for G Type and 280 kW for P Type. It must be confirmed whether the full SANGI ELECTRIC code includes a letter 'G' after 250, as well as verifying the power rating from the nameplate before purchasing.

According to SCMA General Catalog Vol.5, the SG-VB Series inverter supports V/F Control and Torque Control with RS485 Modbus communication for connecting to PLCs, HMIs, and external control systems that support it.

This can be applied in large water pump systems, industrial fans, AHU systems, conveyor belts, and machinery requiring high-power motor speed control by selecting the appropriate power rating based on actual load conditions.

General Features (Features)

  • Brand: SANGI ELECTRIC
  • Model SG-VB-4T250/280P as specified in the product code
  • Benchmark base model code: VB-4T250G/280P
  • SG-VB Series family
  • Type: Industrial Inverter / Variable Frequency Drive
  • For controlling three-phase AC motors
  • Rated power 250 kW for G Type
  • Rated power 280 kW for P Type
  • Suitable for 3 Phase 380 VAC electrical system according to SG-VB Series information
  • Supports V/F Control
  • Supports Torque Control
  • Supports RS485 Modbus Communication
  • Supports Digital Input and Analog Input connections as per SG-VB Series data
  • Suitable for overload capacity according to G Type and P Type specifications
  • Fits high-power motor control systems and Factory Automation applications

Technical Specifications (Technical Specifications)

SpecificationsDetails
BrandSANGI ELECTRIC
ModelSG-VB-4T250/280P
Reference ModelVB-4T250G/280P (Verify Exact SANGI Model Code) SeriesSG-VB Product TypeIndustrial Inverter / Variable Frequency Drive Motor TypeThree-Phase AC Motor G Type Motor Power250 kW (Matching VB Series Reference) P Type Motor Power280 kW (Matching VB Series Reference) Power Capacity G/P355 / 396 kVA (Matching VB Series Reference) Input Phase3 Phase Nominal Input Voltage380 VAC (SG-VB Series) Input Voltage Tolerance±15% (SG-VB Series) Input Frequency50/60 Hz ±15% (SG-VB Series) Rated Input Current G/P468 / 525 A (Matching VB Series Reference) Output Voltage3 Phase 0-380 VAC (SG-VB Series) Rated Output Current G/P465 / 520 A (Matching VB Series Reference) Control MethodV/F Control / Torque Control V/F Output Frequency0-1000 Hz (SG-VB Series) SVC Output Frequency0-320 Hz (SG-VB Series) G Type Starting Torque150% at 0.5 Hz (SVC, SG-VB Series) P Type Starting Torque100% at 0.5 Hz (SG-VB Series) G Type Overload Capacity150% for 60 s / 180% for 1 s P Type Overload Capacity120% for 60 s / 150% for 1 s Digital Inputs6 Channels, NPN (SG-VB Series) Analog Inputs2 Channels, 0-10 V / 4-20 mA (SG-VB Series) Digital OutputsRelay Contact NO/NC and 1 NPN Output (SG-VB Series) Analog Output1 Channel, 0-10 V / 4-20 mA (SG-VB Series) CommunicationRS485 Modbus Protection ClassIP20 (Matching VB Series Reference) Reference Dimensions (H x W x D)1570 x 600 x 408 mm (Matching VB Series Reference) Reference Weight180 kg (Matching VB Series Reference) Integrated Braking FunctionNo (Matching VB Series Reference) Exact SANGI Nameplate RatingsTo Be Confirmed Before Ordering Catalog ReferenceSCMA General Catalog Vol.5, D4-01 to D4-04

Note on Data: Electrical specifications, control functions, signal channels and communication refer to SG-VB Series in SCMA catalog. Power ratings of 250/280 kW, currents of 468/525 A and 465/520 A as well as dimensions and weight reference VB-4T250G/280P with similar codes must be confirmed with SANGI ELECTRIC before use as official specifications

Motor Speed Control (Speed Control of Motor)

The SG-VB Series controls the speed of three-phase AC motors by adjusting frequency and voltage supplied to the motor according to control commands, enabling adjustment of machinery operation to suit production processes.

The use of an Inverter in pump and fan systems with variable torque loads may help reduce energy consumption compared to constant-speed operation. This depends on the system and actual usage patterns.

Power Ratings for G Type and P Type

From the base model VB-4T250G/280P with similar codes, motor power ratings of 250 kW are specified for G Type and 280 kW for P Type, along with different current values according to usage type.

RatingG TypeP Type
Motor Power250 kW280 kW
Power Capacity355 kVA396 kVA
Reference Input Current468 A525 A Reference Output Current465 A520 A Overload Capacity (60 s)150%120% Overload Capacity (1 s)180%150%

G Type is suitable for consideration in systems requiring high overload capacity, while P Type is suited to loads that match the power and current ratings, such as properly designed fan or pump systems.

The motor current, starting torque, acceleration time, deceleration time, and Duty Cycle must be checked before selection. Selection should not be based on kW rating alone.

V/F Control

The SG-VB Series inverter supports V/F control to manage the relationship between voltage and frequency supplied to the motor for speed adjustment according to system control commands.

Parameter settings must match the Nameplate, such as Rated Voltage, Rated Current, Rated Frequency, and Rated Speed.

Torque Control

The SG-VB Series supports Torque Control for use in systems requiring motor torque control based on machine conditions. The setup method and limitations of the control mode should be checked from the manufacturer's manual.

RS485 Modbus Communication

The SG-VB Series supports RS485 Modbus communication to connect inverters with PLCs, HMIs, or external control systems that support the same protocol.

Communication settings should be verified for Baud Rate, Device Address, Register Map, and Data Frame format from the manufacturer's manual. Proper wiring of RS485 and noise protection must also be considered.

Digital Input and Analog Input

The SG-VB Series has 6 digital inputs (NPN type) and 2 analog inputs for 0-10 V or 4-20 mA signals to connect with external control systems, according to the catalog data.

Before wiring, check the electrical ratings of the signal channels and Terminal Assignment of the installed model.

Digital Output and Analog Output

The SG-VB Series provides outputs for sending status or data signals to external control devices such as Relay Contact, NPN Digital Output, and Analog Output, according to catalog information.

Check the signal type, current rating, and programmable functions of each output channel before connecting to a PLC or other device.

Overload Capability

Operating Type60 Seconds1 Second
G Type150% Rated Current180% Rated Current
P Type120% Rated Current150% Rated Current

The overload capability values are general information for the SG-VB Series. Consider operating conditions, environmental temperature, and power rating limitations.

Reference Dimensions

The base model VB-4T250G/280P used as a reference has dimensions of 1570 x 600 x 408 mm (H x W x D) and weighs approximately 180 kg. These figures are not definitive for SANGI ELECTRIC SG-VB-4T250/280P.

Installation must allow space for cooling, power wiring, accessory installation, and access for maintenance as per the manufacturer's manual.

Braking System

A high-power inverter requires consideration of a braking system based on load characteristics such as rapid stop or deceleration. This may require an external Braking Unit and Braking Resistor according to the manufacturer’s specifications.

The base model VB-4T250G/280P specifies no Integrated Braking Function, but check the actual SANGI ELECTRIC model's braking circuit configuration before use.

Do not connect a brake resistor directly to the DC Bus without documentation stating support and verify the Wiring Diagram each time before installation.

Applications

  • Three-phase motor speed control systems
  • High-capacity water pump systems in industrial plants
  • Industrial fan and ventilation systems
  • AHU and industrial air conditioning systems
  • Belt conveyor systems with suitable load ratings
  • High-power machinery control systems
  • Inverter control through PLC or HMI
  • Factory Automation and Process Control Systems

Selecting SG-VB-4T250/280P Guidelines

  • Confirm the full model number includes a G after 250.
  • Check the power rating from the Nameplate of SANGI ELECTRIC
  • Verify motor power at 250 kW or 280 kW depending on load type
  • Check supply voltage and number of phases
  • Compare motor current with inverter output current
  • Select G Type or P Type to suit overloading requirements
  • Check torque and acceleration time
  • Verify compatibility with RS485 Modbus
  • Check installation space and cooling system
  • Review protective devices, braking systems, and Wiring Diagram before ordering
  • Installation Precautions

    • Hire a qualified electrical engineer for installation and inspection
    • Verify number of phases and supply voltage before energizing
    • Select wiring and protection equipment based on actual current rating
    • Install grounding according to manufacturer specifications and relevant standards
    • Design cooling system suitable for high-power inverters
    • Separate motor power cables from signal and communication lines
    • Connect motor leads at terminals U, V, and W as per manual
    • Configure motor parameters before operation
    • Evaluate the need for an External Braking Unit
    • Design Emergency Stop and Safety systems to match machine risk level
    • De-energize, lock out power source, and verify DC Bus voltage is zero before maintenance

    Important Notes

    • The product is the SANGI ELECTRIC inverter model SG-VB-4T250/280P as specified by the code
    • The base model number for comparison is VB-4T250G/280P
    • Power rating of 250/280 kW is reference data from the base VB Series model
    • Supports V/F Control and Torque Control as per SG-VB Series
    • Supports RS485 Modbus
    • Incoming current at 468/525 A and outgoing current at 465/520 A are reference data from the VB model
    • Size and weight must be verified from SANGI ELECTRIC documentation before use as design information
  • Should confirm the letter G in the product code and check the Nameplate before purchasing