SG-VB-4T220G/250P Inverter SANGI ELECTRIC

Price on request – please contact us
Out of stock
SKU
051059
Out of stock

The price for this item is not shown online yet.

Ask for a price on LINE

SANGI ELECTRIC SCMA

SANGI ELECTRIC SG-VB-4T220G/250P, SG-VB-4T220G/250P Inverter, SANGI SG-VB Series, Industrial Inverter, Variable Frequency Drive, VFD, AC Motor Drive, Three Phase Motor Inverter, Three Phase 380VAC Inverter, 220kW G Type Inverter, 250kW P Type Inverter, 220kW 250kW VFD, Heavy Duty Inverter, Normal Duty Inverter, Variable Speed Drive, V/F Control, Torque Control, RS485 Modbus Inverter, Industrial Motor Speed Control, Three Phase AC Motor Control, High Power Inverter, Industrial Automation Drive, Pump Inverter, Fan Inverter, HVAC Motor Drive, AHU Inverter, Conveyor Drive, Industrial Motor Controller, Factory Automation, Process Control, SANGI ELECTRIC Inverter Thailand, SANGI ELECTRIC Inverter, SG-VB Inverter, Three Phase Inverter, 380VAC Inverter, 220kW Inverter, 250kW Inverter, High Power Inverter, Variable Speed Motor Control, VFD for Pump and Fan, Conveyor Drive Inverter, Industrial Motor Controller, RS485 Modbus Inverter, Automated Motor Control System, SG-VB-4T220G/250P Thailand

*Price does not include VAT

SANGI ELECTRIC SG-VB-4T220G/250P (Industrial Variable Frequency Drive)

SANGI ELECTRIC SG-VB-4T220G/250P is an Inverter or Variable Frequency Drive (VFD) in the SG-VB Series for controlling the speed of three-phase AC motors by adjusting the output frequency and voltage to match the motor's operational characteristics and industrial machinery requirements.

The model SG-VB-4T220G/250P corresponds to the base model VB-4T220G/250P, which specifies a power rating of 220 kW for G Type and 250 kW for P Type. The actual power and current ratings must be confirmed from the Nameplate or Datasheet of SANGI ELECTRIC before selecting for use.

The SG-VB Series Inverter supports V/F Control and Torque Control, along with RS485 Modbus communication for connecting to PLCs, HMIs, and compatible automation control systems.

It is suitable for large water pump systems, industrial fans, AHU systems, conveyor belts, and motor-driven machinery that require speed adjustment according to the production process. The correct power rating must be selected based on actual load conditions.

Features

  • Brand: SANGI ELECTRIC
  • Model: SG-VB-4T220G/250P
  • Series: SG-VB Series
  • Type: Industrial Inverter / Variable Frequency Drive
  • For controlling three-phase AC motors
  • Rated power 220 kW for G Type
  • Rated power 250 kW for P Type
  • Suitable for 3 Phase 380 VAC electrical system as per SG-VB Series data
  • Supports V/F Control and Torque Control
  • Supports RS485 Modbus Communication
  • Supports Digital Input and Analog Input connections as per SG-VB Series data
  • Able to handle overloads according to G Type and P Type ratings
  • Suitable for Factory Automation and Machine Control systems

Technical Specifications

Specifications Details
BrandSANGI ELECTRIC
ModelSG-VB-4T220G/250P
SeriesSG-VB
Product TypeIndustrial Inverter / VFD
Motor TypeThree-Phase AC Motor
G Type Motor Power220 kW (Matching VB Series Reference)
P Type Motor Power250 kW (Matching VB Series Reference)
Power Capacity G/P280 / 355 kVA (Matching VB Series Reference)
Input Phase3 Phase
Nominal Input Voltage380 VAC (SG-VB Series)
Input Voltage Tolerance±15% (SG-VB Series)
Input Frequency50/60 Hz ±15% (SG-VB Series)
Rated Input Current G/P430 / 468 A (Matching VB Series Reference)
Output Voltage3 Phase 0-380 VAC (SG-VB Series)
Rated Output Current G/P426 / 465 A (Matching VB Series Reference)
Control MethodV/F Control / Torque Control
V/F Output Frequency0-1000 Hz (SG-VB Series)
SVC Output Frequency0-320 Hz (SG-VB Series)
G Type Starting Torque150% at 0.5 Hz (SVC, SG-VB Series)
P Type Starting Torque100% at 0.5 Hz (SG-VB Series)
G Type Overload Capacity150% for 60 s / 180% for 1 s
P Type Overload Capacity120% for 60 s / 150% for 1 s
Digital Inputs6 Channels, NPN (SG-VB Series)
Analog Inputs2 Channels, 0-10 V / 4-20 mA (SG-VB Series)
Digital OutputsRelay Contact NO/NC and 1 NPN Output (SG-VB Series)
Analog Output1 Channel, 0-10 V / 4-20 mA (SG-VB Series)
CommunicationRS485 Modbus
Protection ClassIP20 (Series Nameplate Reference; Verify Exact Model)
Reference Dimensions (H x W x D)1570 x 600 x 408 mm (Matching VB Series Reference)
WeightTo Be Confirmed from SANGI Datasheet
Braking FunctionExternal Braking Arrangement to Be Confirmed
Exact SANGI Nameplate RatingsTo Be Confirmed Before Ordering
Catalog ReferenceSCMA General Catalog Vol.5, D4-01 to D4-04

Note on Data: Electrical system specifications, control functions, signal channels and communication refer to SG-VB Series in SCMA catalog. Power data of 220/250 kW, current of 430/468 A and 426/465 A as well as dimensions reference model VB-4T220G/250P with matching codes and must be confirmed with SANGI ELECTRIC Datasheet

Motor Speed Control (Speed Control of Motor)

The SG-VB Series is used to control the speed of three-phase AC motors by adjusting the frequency and voltage supplied to the motor according to system control commands, ensuring that machine operation matches production process requirements.

Speed control can help reduce energy consumption in systems with suitable loads such as variable torque pump and fan systems. However, actual energy savings depend on load characteristics and real system settings.

G Type and P Type Power Ratings

Based on the matching basic model VB-4T220G/250P, motor power ratings of 220 kW for G Type and 250 kW for P Type are specified with different current values according to usage capacity.

Rating G Type P Type
Motor Power220 kW250 kW
Power Capacity280 kVA355 kVA
Reference Input Current430 A468 A
Reference Output Current426 A465 A
Overload Capacity (60 s)150%120%
Overload Capacity (1 s)180%150%

G Type is suitable for applications requiring high overload capacity, while P Type is suitable for loads that match the power and current ratings, such as properly designed water pump or fan systems.

The specific rating data provided are reference values of the VB Series. It must be verified against the Nameplate of SANGI ELECTRIC products before selecting protective equipment or designing an electrical system.

V/F Control

The SG-VB Series supports V/F control to manage the relationship between voltage and frequency supplied to the motor, adjusting speed according to commands from a control system.

Motor data such as Rated Voltage, Rated Current, Rated Frequency, and Rated Speed must be set in accordance with the motor's Nameplate before use.

Torque Control

The SG-VB Series supports Torque Control for systems requiring motor torque control according to machine specifications. Proper configuration methods and mode limitations should be reviewed from the manufacturer’s manual.

RS485 Modbus Communication

The SG-VB Series inverters support RS485 Modbus communication for connecting with PLC, HMI or external control systems that support the same protocol.

Communication settings must be verified according to Baud Rate, Device Address, Register Map and Data Frame format from the manual. Proper wiring of RS485 and noise protection measures should also be considered.

Digital Input and Analog Input

The SG-VB Series has 6 Digital Inputs (NPN type) and 2 Analog Inputs supporting signals of 0-10 V or 4-20 mA for connecting external control devices.

Usage must be verified according to Terminal Assignment and signal voltage ratings as per the actual model manual.

Digital Output and Analog Output

The SG-VB Series provides outputs for sending status signals and data to external control devices, including Relay Contact, NPN Digital Output, and Analog Output as specified in the catalog.

Before wiring circuits, signal types, current ratings, and functions that can be assigned to each output should be verified from the manufacturer’s manual.

Overload Capability

Operating Type 60 Seconds 1 Second
G Type150% Rated Current180% Rated Current
P Type120% Rated Current150% Rated Current

Overshoot load values are general information for SG-VB Series. Actual operating conditions, run time, and additional derating based on ambient temperature must be verified.

Dimensions and Installation (Reference Dimensions)

The basic model VB-4T220G/250P specifies the reference dimensions of 1570 x 600 x 408 mm (H x W x D). These dimensions are not confirmed by SANGI ELECTRIC until specific Dimension Drawing is reviewed.

The control cabinet design must accommodate space for heat dissipation, power wiring distance, and maintenance access as per the manufacturer's requirements.

Braking System and Accessories

For high-power inverters, it should be verified whether an External Braking Unit and Braking Resistor are necessary based on load characteristics such as rapid stop or deceleration operations.

A Braking Resistor must not be directly connected to the DC Bus unless confirmed by a manual that supports this. Wiring Diagram and equipment ratings must be checked before installation.

Examples of Applications

  • Three-phase motor speed control systems
  • High-capacity water pump systems in industrial plants
  • Industrial fans and ventilation systems
  • AHU and industrial air conditioning systems
  • Belt conveyors with suitable load ratings
  • Motion control of high-power machinery
  • Inverter control through PLC or HMI
  • Factory Automation and Process Control Systems

Selecting SG-VB-4T220G/250P Guidelines

  • Verify the model code and power rating from the SANGI ELECTRIC nameplate.
  • Check motor power of 220 kW or 250 kW based on load characteristics.
  • Verify supply voltage and number of phases.
  • Compare motor current with inverter output current.
  • Select G Type or P Type according to the requirement for overload capacity.
  • Check starting torque and acceleration time.
  • Verify RS485 Modbus communication compatibility.
  • Review installation space and cooling system.
  • Check necessary protective devices and braking systems.
  • Check Datasheet and Wiring Diagram before ordering
  • Installation Precautions

    • Hire qualified electrical personnel to install and test the product
    • Verify number of phases and voltage before energizing
    • Select wire size and protective devices according to actual rated current
    • Connect grounding wires as per manufacturer's specifications and relevant standards
    • Properly design cooling systems for high-power inverters
    • Separate motor power cables from signal and communication lines
    • Check motor connection to terminals U, V, and W according to Wiring Diagram
    • Set motor parameters before running the system
    • Evaluate the necessity of an External Braking Unit
    • Design Emergency Stop and Safety systems suitable for machine risk levels
    • De-energize, lock out power source, and verify that DC Bus has no voltage before maintenance

    Important Notes

    • This product is the SANGI ELECTRIC SG-VB-4T220G/250P inverter model
    • Belonging to the SG-VB Series family
    • The rating of 220/250 kW is reference data from the VB-4T220G/250P model
    • Supports V/F Control and Torque Control as per the SG-VB Series catalog
    • Supports RS485 Modbus
    • The input current of 430/468 A and output current of 426/465 A are reference data from comparable VB models
    • The dimensions of 1570 x 600 x 408 mm are reference dimensions from comparable VB models
    • Must verify the Nameplate and Datasheet of SANGI ELECTRIC before confirming specific model ratings
    • Must check compatibility with motors and accessories prior to installation
    Write Your Own Review
    You're reviewing:SG-VB-4T220G/250P Inverter SANGI ELECTRIC
    Cookie settings
    🤖 AI Assistant
    Ask about products, specs and replacement models
    Hello 👋 Ask us anything — find products, compare specs, or troubleshoot.
    🗑 Clear history