SANGI ELECTRIC Inverter Model SG-VB-4T132G/160P (Industrial Variable Frequency Drive)
SANGI ELECTRIC SG-VB-4T132G/160P is an inverter or Variable Frequency Drive (VFD) from the SG-VB Series designed to control the speed of three-phase AC motors by adjusting the output frequency and voltage to match the motor's operational characteristics.
The model code SG-VB-4T132G/160P corresponds to the base model VB-4T132G/160P, which specifies power ratings of 132 kW for G Type and 160 kW for P Type. It is suitable for consideration in high-power motor systems but must be confirmed against the nameplate and datasheet from SANGI ELECTRIC before actual use.
According to SCMA General Catalog Vol.5, the SG-VB Series inverters support V/F Control and Torque Control with RS485 Modbus communication for connecting to external control devices such as PLCs and HMIs that are compatible.
It can be applied in water pump systems, industrial fans, AHU systems, conveyor belts, and motor-driven machinery requiring speed control.
General Features (Features)
- Brand: SANGI ELECTRIC
- Model: SG-VB-4T132G/160P
- Series: SG-VB Series
- Type: Industrial Inverter / Variable Frequency Drive
- For controlling three-phase AC motors
- Rated power 132 kW for G Type
- Rated power 160 kW for P Type
- Suitable for 3 Phase 380 VAC electrical systems as per SG-VB Series data
- Supports V/F Control
- Supports Torque Control
- Supports RS485 Modbus communication
- Includes Digital Input and Analog Input for external control devices according to series specifications
- Able to handle overloading within the rated capacity of G Type and P Type
- Suitable for Factory Automation and Machine Control systems
Technical Specifications (Technical Specifications)
| Specifications | Details |
| Brand | SANGI ELECTRIC |
| Model | SG-VB-4T132G/160P |
| Series | SG-VB |
| Product Type | Industrial Inverter / VFD |
| Motor Type | Three-Phase AC Motor |
| G Type Motor Power | 132 kW (Matching VB Series Reference) |
| P Type Motor Power | 160 kW (Matching VB Series Reference) |
| Power Capacity G/P | 192 / 231 kVA (Matching VB Series Reference) |
| Input Phase | 3 Phase |
| Nominal Input Voltage | 380 VAC (SG-VB Series) |
| Input Voltage Tolerance | ±15% (SG-VB Series) |
| Input Frequency | 50/60 Hz ±15% (SG-VB Series) |
| Rated Input Current G/P | 256 / 307 A (Matching VB Series Reference) |
| Output Voltage | 3 Phase 0-380 VAC (SG-VB Series) |
| Rated Output Current G/P | 253 / 304 A (Matching VB Series Reference) |
| Control Method | V/F Control / Torque Control |
| V/F Output Frequency | 0-1000 Hz (SG-VB Series) |
| SVC Output Frequency | 0-320 Hz (SG-VB Series) |
| G Type Starting Torque | 150% at 0.5 Hz (SVC, SG-VB Series) |
| P Type Starting Torque | 100% at 0.5 Hz (SG-VB Series) |
| G Type Overload Capacity | 150% for 60 s / 180% for 1 s |
| P Type Overload Capacity | 120% for 60 s / 150% for 1 s |
| Digital Inputs | 6 Channels, NPN (SG-VB Series) |
| Analog Inputs | 2 Channels, 0-10 V / 4-20 mA (SG-VB Series) |
| Digital Outputs | Relay Contact NO/NC and NPN Output (SG-VB Series) |
| Analog Output | 1 Channel, 0-10 V / 4-20 mA (SG-VB Series) |
| Communication | RS485 Modbus |
| Protection Class | <IP20 (SG-VB Series Catalog Reference) |
| Reference Dimensions (H x W x D) | 1199 x 502 x 355 mm (Matching VB Series Reference) |
| Reference Mounting Hole Diameter | 10 mm (Matching VB Series Reference) |
| Weight | To Be Confirmed from SANGI Datasheet |
| Exact SANGI Nameplate Ratings | To Be Confirmed Before Ordering |
| Catalog Reference | SCMA General Catalog Vol.5, D4-01 to D4-04 |
Note on Data: Voltage specs, control system, signal channels and communication refer to general SG-VB Series data in the SCMA catalog. Power 132/160 kW, current 256/307 A and 253/304 A as well as dimensions reference model VB-4T132G/160P with matching codes but still to be confirmed against SANGI ELECTRIC documentation.
Motor Speed Control
The SG-VB Series inverter controls the speed of three-phase AC motors by adjusting output frequency and voltage to match motor operation, allowing setting machine speeds according to production processes.
It can be applied to water pumps, fans, ventilation systems, and conveyors requiring variable speed control. Energy savings depend on load characteristics and system design.
G Type and P Type Power Ratings
The code SG-VB-4T132G/160P corresponds to the basic model VB-4T132G/160P, specifying power ratings for different G Type and P Type usage patterns.
| Rating | G Type | P Type |
| Motor Power | 132 kW | 160 kW |
| Power Capacity | 192 kVA | 231 kVA |
| Reference Input Current | 256 A | 307 A |
| Reference Output Current | 253 A | 304 A |
| Overload Capacity (60 s) | 150% | 120% |
| Overload Capacity (1 s) | 180% | 150% |
G Type is generally suitable for applications requiring high overload capacity, while P Type is better suited for loads that match the power and current ratings, such as fans or pumps with appropriate load characteristics.
Inverter selection should not be based solely on kW rating; motor current rating, starting torque duty cycle, temperature limitations, and installation constraints must also be considered.
V/F Control
The SG-VB Series supports V/F control to manage the relationship between voltage and frequency supplied to the motor, allowing for speed regulation according to system control commands.
Proper parameter settings for motor type and load characteristics are necessary to prevent operation outside of system limitations.
Torque Control
The SG-VB Series supports Torque Control as per the catalog data, suitable for systems requiring motor torque behavior regulation.
It is advisable to review the manufacturer's manual regarding mode conditions and setup procedures before actual use.
RS485 Modbus Communication
The SG-VB Series supports RS485 Modbus communication for connecting inverters with PLC, HMI, or external control systems that support the same protocol.
Installation requires checking Baud Rate, Slave Address, Register Map, Data Frame format, and RS485 wiring according to the manufacturer's manual. Proper commands such as RUN/STOP and Frequency Reference must also be set up accordingly.
Digital Input and Analog Input
The SG-VB Series has 6 digital inputs (NPN type) and 2 analog inputs for receiving standard signals of 0-10 V or 4-20 mA, as per the catalog data.
These signals can be used as external control inputs according to supported functions by the manufacturer. Terminal positions and parameter settings must be verified before connection.
Digital Output and Analog Output
The SG-VB Series provides outputs for use with external control circuits, including Relay Contact, NPN Digital Output, and Analog Output, as per catalog data.
Usage should verify output current ratings, signal ranges, and terminal connections of the actual model to match the controlled device requirements.
Overload Capability
| Operating Type | 60 Seconds | 1 Second |
| G Type | 150% Rated Current | 180% Rated Current |
| P Type | 120% Rated Current | 150% Rated Current |
The overload data is a general specification of the SG-VB Series. It is necessary to verify the time conditions, environmental temperature, and power rating reduction before using it for machine design.
Reference Dimensions and Installation
Based on the standard model VB-4T132G/160P, the reference dimensions are H 1199 mm, W 502 mm, and D 355 mm. These dimensions should not be considered as confirmed product information for SANGI ELECTRIC SG-VB-4T132G/160P until the actual model drawing is verified.
The control cabinet design must allow for heat dissipation space, wiring space, and maintenance space according to the manufacturer's manual. The machine dimensions should not be used directly as the control cabinet size.
Braking System and Accessories
For high-power inverters, an External Braking Unit, Braking Resistor, or other accessories must be considered based on the manufacturer’s specifications and load characteristics.
The Braking Resistor should not be directly connected to the DC Bus unless specified in the documentation that the model supports such a connection. Wiring Diagrams and equipment ratings must be checked before installation.
Applications
- Three-phase motor speed control system
- High-capacity water pump systems in industrial plants
- Industrial fans and ventilation systems
- AHU and industrial air conditioning systems
- Belt conveyors with suitable load ratings
- Machinery control systems requiring variable speed adjustment
- Inverter control through PLC and HMI
- Factory Automation and Process Control Systems
Selecting SG-VB-4T132G/160P Guidelines
- Check the model code and power from the SANGI ELECTRIC nameplate.
- Verify motor power of 132 kW or 160 kW based on usage patterns.
- Confirm three-phase 380 VAC power supply system.
- Compare motor rated current with inverter output current.
- Select G Type or P Type according to load characteristics.
Check torque requirements during startup and acceleration
Verify RS485 Modbus compatibility with the control system
Inspect installation area and cooling system
Inspect protective devices, braking systems, and accessories
Review Datasheet and Wiring Diagram before ordering
Installation Precautions
- Hire qualified electrical personnel for installation and testing
- Verify number of phases and voltage before energizing
- Select wire size and protective devices suitable for actual current usage
- Install grounding according to manufacturer's specifications
- Install in an area with appropriate cooling
- Separate motor power cables from signal and communication wires
- Connect the motor terminals U, V, and W as per Wiring Diagram
- Check motor parameters before starting RUN command
- Select External Braking Unit and Braking Resistor according to model specifications
- Design Emergency Stop and Safety circuits suitable for machine risks
- De-energize, lock out power source, and verify that DC Bus has no voltage before maintenance
Important Notes Before Ordering
- This product is the SANGI ELECTRIC SG-VB-4T132G/160P inverter model
- Belonging to the SG-VB Series family
- The power rating of 132/160 kW is reference data from the VB-4T132G/160P model
- Supports V/F Control and Torque Control according to SG-VB Series information
- Supports RS485 Modbus
- The input current of 256/307 A and output current of 253/304 A are data from the comparable VB model
- The dimensions of 1199 x 502 x 355 mm are reference dimensions from the comparable VB model
- Must verify Nameplate and Datasheet of SANGI ELECTRIC before ordering
- Must check compatibility with motor and accessories before installation