SANGI ELECTRIC Inverter Model SG-VB-4T110G/132P (Industrial Variable Frequency Drive)
SANGI ELECTRIC SG-VB-4T110G/132P is an inverter or Variable Frequency Drive (VFD) for controlling the speed of three-phase AC motors. It belongs to the SG-VB Series and can be applied in machine control systems and industrial production processes.
The model number SG-VB-4T110G/132P corresponds to the basic model VB-4T110G/132P with a power rating of 110 kW for G Type and 132 kW for P Type. The actual power and current ratings should be confirmed from the Nameplate or Datasheet of SANGI ELECTRIC before selecting it for use.
The SG-VB Series supports V/F Control and Torque Control, along with RS485 Modbus communication protocol. It can be used to design speed control systems in conjunction with PLCs, HMIs, and compatible automation systems.
It is suitable for water pump systems, AHU fans, conveyor systems, and industrial machinery that require speed adjustment. The correct inverter rating must be selected based on the motor power, load current, and operating conditions.
General Features (Features)
- Brand: SANGI ELECTRIC
- Model: SG-VB-4T110G/132P
- Series: SG-VB Series
- Type: Industrial Inverter / Variable Frequency Drive
- For controlling three-phase AC motors
- Rated power 110 kW for G Type
- Rated power 132 kW for P Type
- Electrical system: Three Phase 380 VAC as per SG-VB Series data
- Supports V/F Control and Torque Control
- Supports RS485 Modbus
- Supports Digital Input and Analog Input channels as per SG-VB Series data
- Has overload capacity based on G Type or P Type selection
- Suitable for Machine Control and Factory Automation applications
Technical Specifications (Technical Specifications)
| Specifications | Details |
| Brand | SANGI ELECTRIC |
| Model | SG-VB-4T110G/132P |
| Series | SG-VB |
| Product Type | Industrial Inverter / VFD |
| Motor Type | Three-Phase AC Motor |
| G Type Motor Power | 110 kW (Matching VB Series Reference) |
| P Type Motor Power | 132 kW (Matching VB Series Reference) |
| Power Capacity G/P | 160 / 192 kVA (Matching VB Series Reference) |
| Input Phase | 3 Phase |
| Nominal Input Voltage | 380 VAC (SG-VB Series) |
| Input Voltage Tolerance | ±15% (SG-VB Series) |
| Input Frequency | 50/60 Hz ±15% (SG-VB Series) |
| Rated Input Current G/P | 214 / 256 A (Matching VB Series Reference) |
| Output Voltage | 3 Phase 0-380 VAC (SG-VB Series) |
| Rated Output Current G/P | 210 / 253 A (Matching VB Series Reference) |
| Control Method | V/F Control / Torque Control |
| V/F Output Frequency | 0-1000 Hz (SG-VB Series) |
| SVC Output Frequency | 0-320 Hz (SG-VB Series) |
| G Type Starting Torque | 150% at 0.5 Hz (SVC, SG-VB Series) |
| P Type Starting Torque | 100% at 0.5 Hz (SG-VB Series) |
| G Type Overload Capacity | 150% for 60 s / 180% for 1 s |
| P Type Overload Capacity | 120% for 60 s / 150% for 1 s |
| Digital Inputs | 6 Channels, NPN (SG-VB Series) |
| Analog Inputs | 2 Channels, 0-10 V / 4-20 mA (SG-VB Series) |
| Digital Outputs | Relay Contact NO/NC and NPN Output (SG-VB Series) |
| Analog Output | 0-10 V / 4-20 mA (SG-VB Series) |
| Communication | RS485 Modbus |
| Protection Class | IP20 (Matching VB Series Reference) |
| Reference Dimensions (H x W x D) | 690 x 498 x 405 mm (Matching VB Series Reference) |
| Reference Weight | 39 kg (Matching VB Series Reference) |
| Exact SANGI Nameplate Ratings | To Be Confirmed Before Ordering |
| Catalog Reference | SCMA General Catalog Vol.5, D4-01 to D4-04 |
Note on Data: The voltage, control system, communication and signal channel information are general specifications of the SG-VB Series as per SCMA catalog. However, the power rating 110/132 kW, current 214/256 A and 210/253 A, along with the unit dimensions, pertain to model VB-4T110G/132P which has matching power codes but must be confirmed with SANGI ELECTRIC.
Motor Speed Control
The SG-VB Series controls the speed of three-phase AC motors by adjusting the output frequency and voltage to suit motor operation and system requirements.
The use of an Inverter allows for variable speed control of pumps, fans or other driven equipment based on actual workload, which may help reduce energy consumption in systems with varying torque loads.
G Type and P Type Power Ratings
According to the basic model table of VB Series, the code VB-4T110G/132P has a power rating of 110 kW for G Type and 132 kW for P Type with differing current values based on usage type.
| Rating | G Type | P Type |
| Motor Power | 110 kW | 132 kW |
| Power Capacity | 160 kVA | 192 kVA |
| Reference Input Current | 214 A | 256 A |
| Reference Output Current | 210 A | 253 A |
| Overload Capacity (60 s) | 150% | 120% |
| Overload Capacity (1 s) | 180% | 150% |
The selection of G Type or P Type must consider load characteristics, motor current, starting conditions, frequency of speed acceleration or deceleration and the system's overload capacity.
The numbers for power and current in the table are reference data from the comparable VB Series model. Therefore, it is necessary to check with the Nameplate of SANGI ELECTRIC products before purchasing.
V/F Control System
The SG-VB Series supports V/F Control which adjusts the relationship between voltage and frequency supplied to the motor in order to control speed according to system operation requirements.
It can be applied to water pumps, fans, and machinery with suitable load characteristics by setting parameters that match the installed motor.
Torque Control and Torque Management
The SG-VB Series inverters support Torque Control as per the catalog for systems requiring motor torque behavior control.
Settings must consider Motor Nameplate data, load characteristics, and supported control methods to prevent overloading of machinery.
RS485 Modbus Communication
The SG-VB Series supports RS485 Modbus communication to connect with PLCs, HMIs, or external control devices that support the same protocol.
It is necessary to check the Modbus Register Map, Baud Rate, Slave Address, and RS485 wiring from the actual model manual before connecting to an automatic control system.
Control Signal Channels (Control Inputs and Outputs)
The SG-VB Series has 6 NPN Digital Input channels and 2 Analog Input channels for receiving standard signals of 0-10 V or 4-20 mA as per the catalog data.
There are outputs to send status and control information to external systems, including NO/NC relay contact output, NPN output, and Analog Output. Terminal Assignment must be checked before connecting.
Overload Capability
| Operating Type | 60 Seconds | 1 Second |
| G Type | 150% Rated Current | 180% Rated Current |
| P Type | 120% Rated Current | 150% Rated Current |
The above data is the overload capability according to the SG-VB Series catalog. Additional operating conditions must be checked, such as usage time, ambient temperature, and power rating reduction when necessary.
Braking System and Accessories
For high-power inverters, the braking system design must check the use of External Braking Unit and Braking Resistor according to the actual model user manual.
The braking resistor should not be directly connected to the DC Bus terminals. If the manufacturer specifies that an external braking unit is required, the resistance value must be verified against the device's power rating before installation.
Application Examples (Applications)
- Three-phase motor speed control systems
- Industrial water pump systems
- Industrial fan and ventilation systems
- AHU and industrial air conditioning systems
- Belt conveyor systems with suitable load ratings
- Large machinery control systems
- Inverter control through PLC or HMI
- Factory Automation and Process Control Systems
Selection Guidelines for SG-VB-4T110G/132P
- Check the motor power rating of 110 kW or 132 kW according to the load characteristics
- Confirm the model number and current value from the SANGI ELECTRIC nameplate
- Verify the input voltage, three-phase
- Consider the differences between G Type and P Type
- Check the motor rated current and torque requirements
- Check RS485 Modbus communication
- Review electrical system, protective devices, and cable size
- Verify installation space and cooling capacity
- Check usage of Braking Unit and accessories
- Review Wiring Diagram and manual before ordering
Installation Precautions
- Hire a qualified electrician or personnel with electrical system knowledge for installation
- Verify the number of phases and voltage before energizing
- Select cables and protective devices according to actual current usage
- Connect grounding wires and prevent leakage as per manufacturer's specifications
- Properly arrange space within control cabinet for heat dissipation
- Separate motor power cables from signal and communication cables
- Connect the motor terminals U, V, W according to manual instructions
- Check motor parameters before starting operation (RUN)
- Select External Braking Unit when necessary and as per model specifications
- Design Emergency Stop and Safety circuits suitable for machinery risk level
- De-energize, lock out power source, and verify that DC Bus has no voltage before maintenance
Important Notes Before Ordering (Important Notes)
- The product is an inverter from SANGI ELECTRIC model SG-VB-4T110G/132P
- It belongs to the SG-VB Series family
- Powers rating 110/132 kW based on the VB-4T110G/132P model with matching power codes
- SUPPORTS V/F Control and Torque Control as per SG-VB Series data
- Supports RS485 Modbus communication
- The reference current value for the VB model is Input 214/256 A and Output 210/253 A
- Size and weight information from the comparable VB model still needs to be confirmed with SANGI
- Motor compatibility and accessory fitment must be checked before purchase