SANGI ELECTRIC Inverter Model SG-VB-093G/110P (Industrial Variable Frequency Drive)
SANGI ELECTRIC SG-VB-093G/110P is an inverter or Variable Frequency Drive (VFD) designed to control the speed of three-phase AC motors in industrial systems. It belongs to the SG-VB Series, which is tailored for adjusting motor speeds and controlling operations according to production process requirements.
The code SG-VB-093G/110P corresponds to the power rating of the base model VB-4T093G/110P, indicating a motor rating of 93 kW for G Type and 110 kW for P Type. Before confirming order details, it is essential to verify the full model name and ratings on the SANGI ELECTRIC product Nameplate.
The SG-VB Series supports V/F Control and Torque Control along with RS485 Modbus communication, allowing integration into motor speed control systems designed alongside PLCs or HMIs that support such standard communications.
It is suitable for applications in water pump systems, fans, AHU ventilation systems, conveyor systems, and industrial machinery requiring speed control. Proper selection of power ratings and usage patterns must match the actual load requirements.
General Features (Features)
- Brand: SANGI ELECTRIC
- Model: SG-VB-093G/110P as specified
- Series: SG-VB Series
- Type: Industrial Inverter / Variable Frequency Drive
- For controlling the speed of three-phase AC motors
- Rated power 93 kW for G Type and 110 kW for P Type
- Supports three-phase electrical system, 380 VAC as per SG-VB Series data
- Supports V/F Control
- Supports Torque Control
- Supports RS485 Modbus communication
- Includes Digital Input and Analog Input for external control systems as per SG-VB Series information
- Suitable for water pump and fan control applications
- Fits Machine Control and Factory Automation tasks
Technical Specifications (Technical Specifications)
| Specifications | Details |
| Brand | SANGI ELECTRIC |
| Model | SG-VB-093G/110P |
| Series | SG-VB |
| Product Type | Industrial Inverter / Variable Frequency Drive |
| Motor Type | Three-Phase AC Motor |
| G Type Motor Power | 93 kW (Matching VB Series Reference) |
| P Type Motor Power | 110 kW (Matching VB Series Reference) |
| Power Capacity G/P | 134 / 160 kVA (Matching VB Series Reference) |
| Input Phase | 3 Phase |
| Nominal Input Voltage | 380 VAC (SG-VB Series) |
| Input Voltage Tolerance | ±15% (SG-VB Series) |
| Input Frequency | 50/60 Hz ±15% (SG-VB Series) |
| Rated Input Current G/P | 180 / 214 A (Matching VB Series Reference) |
| Output Voltage | 3 Phase 0-380 VAC (SG-VB Series) |
| Rated Output Current G/P | 170 / 210 A (Matching VB Series Reference) |
| Control Method | V/F Control / Torque Control |
| V/F Output Frequency | 0-1000 Hz (SG-VB Series) |
| SVC Output Frequency | 0-320 Hz (SG-VB Series) |
| G Type Starting Torque | 150% at 0.5 Hz (SVC, SG-VB Series) |
| P Type Starting Torque | 100% at 0.5 Hz (SG-VB Series) |
| G Type Overload Capacity | 150% for 60 s / 180% for 1 s |
| P Type Overload Capacity | 120% for 60 s / 150% for 1 s |
| Digital Inputs | 6 Channels, NPN (SG-VB Series) |
| Analog Inputs | 2 Channels, 0-10 V / 4-20 mA (SG-VB Series) |
| Digital Outputs | Relay Contact NO/NC and NPN Output (SG-VB Series) |
| Analog Output | 0-10 V / 4-20 mA (SG-VB Series) |
| Communication | RS485 Modbus |
| Protection Class | IP20 (Matching VB Series Reference) |
| Reference Dimensions (H x W x D) | 690 x 498 x 405 mm (Matching VB Series Reference) |
| Reference Weight | <39 kg (Matching VB Series Reference) |
| Exact SANGI Nameplate Ratings | To Be Confirmed Before Ordering |
| Catalog Reference | SCMA General Catalog Vol.5, D4-01 to D4-04 |
Note on Product Specifications: The control data, voltage, and communication specifications are general for the SG-VB Series as per the SCMA catalog. However, the power rating of 93/110 kW, current ratings of 180/214 A and 170/210 A, along with the unit dimensions, pertain to the base model VB-4T093G/110P which has a similar code. These details must be confirmed from the SANGI ELECTRIC datasheet or nameplate before being used as official specifications.
Motor Speed Control System (Inverter)
The SG-VB Series inverter is designed to control the speed of three-phase AC motors by adjusting the frequency and voltage supplied to the motor, ensuring system performance aligns with production process requirements.
Inverter-based speed control can adjust equipment output levels such as water flow rates in pump systems or air volume in fan systems according to design specifications. Energy savings depend on load type and actual control methods employed.
Power Ratings for G Type and P Type
The base model code VB-4T093G/110P used for reference specifies two power ratings: the G Type has a motor rating of 93 kW, while the P Type has a motor rating of 110 kW.
| Rating | G Type | P Type |
| Reference Motor Power | 93 kW | 110 kW |
| Reference Input Current | 180 A | 214 A |
| Reference Output Current | 170 A | 210 A |
| Overload Capacity, 60 s | 150% | 120% |
| Overload Capacity, 1 s | 180% | 150% |
G Type is generally used for loads that require high overload capacity, while P Type is suitable for loads that match the rated power and current specifications, such as pumps or fans with appropriate characteristics.
The selection of power must consider motor current, load duty cycle, ambient temperature, and additional installation requirements. It should not be based solely on kW values.
V/F Control
The SG-VB Series supports V/F control, which regulates the relationship between voltage and frequency supplied to the motor for appropriate speed adjustment in the system.
It can be applied to fan systems, water pumps, and machinery requiring speed control according to operational characteristics by setting parameters that match the motor and load requirements.
Torque Control and Torque Regulation
The SG-VB Series supports torque control functions as per the catalog data, which is a feature used in system design with motor torque specifications.
Setting up torque regulation requires considering motor information, supported control methods, and machine limitations to ensure proper and safe operation of the system.
Communication RS485 Modbus
The SG-VB Series supports RS485 Modbus communication for connecting with automatic control systems such as PLCs, HMIs, or supervisory control systems that support the same protocol.
The design of communication must verify Modbus Address, Baud Rate, Data Format, Register Map, and RS485 wiring from the inverter manual.
Control Signal Channels (Control Inputs and Outputs)
According to SG-VB Series data, there are 6 NPN digital inputs and 2 analog inputs for receiving signals of 0-10 V or 4-20 mA.
The outputs include relay NO/NC contacts, NPN output, and analog output as per the capabilities of the SG-VB Series. Terminal assignment and function setup methods must be checked before use.
Overload Capability
| Operating Type | 60 Seconds | 1 Second |
| G Type | 150% Rated Current | 180% Rated Current |
| P Type | 120% Rated Current | 150% Rated Current |
The above values are the overload capacity figures from the SG-VB Series catalog, which should be used to select equipment based on load characteristics. Additional operating conditions and power derating according to temperature or environment must also be checked.
Braking System and Accessories (Braking System)
For high-power inverters, the design of the braking system must consider using an External Braking Unit and a Braking Resistor as per the manufacturer's specifications. Do not connect the Braking Resistor to any terminals before checking the actual model power circuit diagram.
In the basic VB Series manual for comparison purposes, model code VB-4T093G/110P provides information on recommending a Braking Resistor and external braking equipment, but compatibility with SANGI ELECTRIC models must be verified before designing and ordering.
Applications
- Three-phase motor speed control system
- Large industrial water pump systems
- Industrial fan and ventilation systems
- AHU and industrial air conditioning systems
- Belt conveyor systems with suitable load ratings
- Machinery speed control systems
- Inverter control through PLC and HMI
- Factory Automation and Process Control Systems
Selection Guidelines for SG-VB-093G/110P
- Check the full model number from the nameplate before ordering
- Confirm power rating of 93 kW or 110 kW according to usage pattern
- Check three-phase supply voltage
- Verify motor rated current and inverter output current
- Consider differences between G Type and P Type
- Evaluate load characteristics and overload capacity
- Check RS485 Modbus connection configuration
- Review inverter size and required cooling distance
- Consider protective devices, braking systems, and accessories
- Refer to the Wiring Diagram and Datasheet before installation
Installation Precautions
- Hire qualified electrical personnel for installation and system checks
- Verify number of phases, supply voltage, and current rating before energizing
- Select wire size and protective devices according to actual current requirements and relevant standards
Connect the grounding wire as per the manufacturer's specifications
Properly arrange cooling space around the inverter
Separate power and signal wires to reduce electrical interference
Check motor connections at terminals U, V, and W according to the Wiring Diagram
Verify motor parameter values before operation
Avoid direct connection of Braking Resistor if an External Braking Unit is required for that model
Design Emergency Stop circuit and Safety system separately based on desired safety level
Disconnect power, lock the supply source, and check that DC Bus has no voltage before maintenance work
Important Notes Before Purchase (Important Notes)
- The product is a SANGI ELECTRIC inverter model SG-VB-093G/110P as specified by the code
- This belongs to the SG-VB Series family of products
- The base model number VB-4T093G/110P has motor ratings 93 kW (G) and 110 kW (P)
- Supports V/F Control and Torque Control as per SG-VB Series data
- Supports RS485 Modbus communication
- The current rating of the base model number must be verified against the SANGI product nameplate
- The size and weight of the SANGI model must be confirmed before designing the control cabinet
- Motor compatibility and accessory fitment must be checked before ordering