SANGI SG-QTLD-DN80 ELECTROMAGNETIC FLOW METER, SG-QTLD-DN80, SANGI SG-QTLD Series, Electromagnetic Flow Meter, Magnetic Flow Meter, Mag Flow Meter, Industrial Flow Meter, DN80 Flow Meter, 3 Inch Flow Meter, 80mm Magnetic Flow Meter, Electromagnetic Induction Flow Meter, Industrial Liquid Flow Meter, Conductive Liquid Flow Meter, Water Flow Meter, Wastewater Flow Meter, Industrial Water Flow Meter, Process Flow Meter, Compact Electromagnetic Flow Meter, Flanged Flow Meter, Magnetic Flow Transmitter, Flow Rate Measurement, 4-20mA Flow Meter, Pulse Output Flow Meter, Modbus Flow Meter, RS485 Modbus Flow Meter, PTFE Liner Flow Meter, Stainless Steel 316L Electrode, Industrial Flow Measurement, Water Treatment Flow Meter, Water Supply Flow Meter, Wastewater Treatment Flow Meter, Pump Station Flow Meter, PLC Flow Meter, HMI Flow Meter, SCADA Flow Meter, Factory Automation, Process Control, SANGI Flow Meter Thailand, Electromagnetic Flow Meter SANGI, Magnetic Field Electric Flow Meter, Electromagnetic Flow Meter, Water Magnetic Flow Meter, DN80 Flow Meter, 3 Inch Flow Meter, 80mm Flow Meter, Water Flow Rate Meter, Wastewater Flow Rate Meter, Industrial Pipe Flow Meter, 4-20mA Flow Meter, Pulse Output Flow Meter, RS485 Modbus Flow Meter, Potable Water Flow Meter, Sewage Treatment Flow Meter, Industrial Plant Flow Meter, SANGI SG-QTLD-DN80 Thailand

*Price does not include VAT

SANGI Electromagnetic Flow Meter Model SG-QTLD-DN80 (Electromagnetic Flow Meter)

SANGI SG-QTLD-DN80 is an electromagnetic flow meter (Electromagnetic Flow Meter) in the SG-QTLD Series for measuring the flow rate of conductive liquids. It is suitable for water supply systems, wastewater treatment systems, water circulation systems, and industrial production processes.

The SG-QTLD-DN80 model is used for pipe systems with DN80 size or approximately 3 inches, measuring flow using the principle of electromagnetic induction (Electromagnetic Induction), without any impeller or rotating mechanical components in the flow path for measuring liquid velocity.

The SG-QTLD Series supports signal options of 4-20mA and Pulse, along with communication options such as Modbus-RS485, HART, or Profibus according to the model configuration, to be used with PLC, HMI, SCADA, and production process control systems.

For the DN80 sub-model with data from SCMA, it features a Compact Type structure, where the display unit is integrated with the meter, using Liner PTFE, Electrode Stainless Steel 316L, and a Cast Iron housing with flange connection. However, the DN80 model has other sub-models using different materials, so it is necessary to check the full model code before ordering.

General Features (Features)

  • SANGI flow meter
  • SG-QTLD-DN80 model in the SG-QTLD Series
  • Type: Electromagnetic Flow Meter
  • Pipe size: DN80 or approximately 3 inches
  • Measured using the principle of Electromagnetic Induction
  • Suitable for conductive liquids
  • No rotating impeller in the flow path for measurement
  • Flow velocity range of the Series: 0.1-15 m/s
  • Standard accuracy of the Series: ±0.5%
  • Accuracy options available: ±0.3% or ±0.2%
  • Supports Analog Output option: 4-20mA
  • Supports Pulse Output option
  • Communication options available: Modbus-RS485, HART, and Profibus
  • Supports connection with PLC, HMI, and SCADA according to sub-models
  • Suitable for flow rate measurement of water and liquids in production processes

Technical Specifications (Technical Specifications)

SpecificationsDetails
BrandSANGI
ModelSG-QTLD-DN80
SeriesSG-QTLD
Product TypeElectromagnetic Flow Meter
Measurement PrincipleElectromagnetic Induction
Nominal Pipe SizeDN80 (3 Inch)
Measured MediumElectrically Conductive Liquids
Series Pipe Size RangeDN3-DN3000 mm
Series Flow Velocity Range0.1-15 m/s
Standard Accuracy±0.5% (Series)
Optional Accuracy±0.3% / ±0.2%
Minimum Liquid Conductivity>5 µS/cm
Demineralized Water Conductivity>20 µS/cm
Reference StructureCompact Type
Reference Maximum Working Pressure1.6 MPa
Reference Medium Temperature-20 to +120 °C
Reference Liner MaterialPTFE
Reference Electrode MaterialStainless Steel 316L
Reference Body MaterialCast Iron
Reference Flange OptionsDIN PN10 / PN16 / PN25 / PN40
Reference Power SupplyAC 85-250 V
Reference Analog Output4-20mA
Reference Pulse OutputAvailable
Reference CommunicationModbus
Reference Protection DegreeIP65
Full Reference ModelSG-QTLD-DN80(3")-S1-P3-L1-E1-K1-F3-D1-G1-G2-C4-F1
Catalog ReferenceSCMA General Catalog Vol.5, E6-01

Note: Values with the word "Reference" in the table are data from the DN80 sub-model code published by SCMA, not fixed requirements for all SG-QTLD-DN80 units. SG-QTLD Series data represents the scope of product features and options.

Working Principle of Electromagnetic Flow Meter

The Electromagnetic Flow Meter operates according to Faraday's Law of Electromagnetic Induction, creating a magnetic field through the measuring tube where electrically conductive liquid flows.

When the liquid moves through the magnetic field, an electromotive force related to the flow velocity is generated. Internal electrodes of the meter detect the generated electrical signal and send it to the processing unit to calculate the flow rate.

This measurement method has no rotating parts in the flow path, reducing maintenance related to rotating components, and is suitable for measuring liquids in piping systems that are properly installed.

Pipe Size DN80 (Nominal Pipe Diameter)

SG-QTLD-DN80 is a DN80 pipe size meter, or approximately 3 inches, for installation in piping systems with sizes and connection standards matching the meter.

The referenced sub-model has standard flange options DIN PN10, PN16, PN25, and PN40. It must be selected to match the actual piping system before ordering. It should not be assumed that meters with DN80 size can be interchanged immediately.

Flow Measurement Range

The SG-QTLD Series specifies a flow velocity range of 0.1-15 m/s, which is data for selecting the meter size and operating range.

The actual flow rate depends on the internal cross-sectional area of the meter and the measurement range setting. Therefore, it is recommended to consider the minimum, normal, and maximum flow rates before selecting for use.

Measurement Accuracy

The SG-QTLD Series has a standard accuracy of ±0.5% and has accuracy options of ±0.3% or ±0.2% according to model specifications and calibration conditions.

For applications requiring high accuracy, it is recommended to check the measurement range, test conditions, and Calibration Certificate to match the actual delivered unit.

Liquid Conductivity

The SG-QTLD Series is suitable for liquids with a conductivity greater than 5 µS/cm, and for Demineralized Water, it must be greater than 20 µS/cm according to the catalog data.

Not suitable for non-conductive liquids such as fuel oil, lubricating oil, or general hydrocarbon liquids, as they cannot be measured appropriately by the electromagnetic induction principle

PTFE Liner Material

The referenced sub-model SG-QTLD-DN80 uses a PTFE liner material, which is used to line the measuring tube and separate the liquid from the housing structure

PTFE has resistance to various types of chemicals, but compatibility with the actual liquid, including temperature, concentration, and pressure conditions, should be checked before use

Stainless Steel 316L Electrode Material

The referenced sub-model uses Stainless Steel 316L electrode material for detecting the electrical signal generated by the flow of liquid through the magnetic field

Before installation, the compatibility of SS316L material with corrosive liquids should be checked, especially for applications involving chemicals or high concentrations

4-20mA Output Signal

The referenced sub-model SG-QTLD-DN80 supports the Analog Output signal 4-20mA for sending flow rate values to PLC, HMI, Data Logger, or compatible control systems

The wiring method, output type, and scaling value should be checked to match the flow rate range defined in the device

Pulse Output

The referenced sub-model supports Pulse Output for sending pulse signals to volume accumulation flow counting systems or external control systems

Before connecting to other devices, the pulse signal type, voltage level, maximum frequency, and pulse scaling value should be checked

Modbus Communication

The referenced sub-model SG-QTLD-DN80 supports Modbus communication for transmitting measurement data to control systems such as PLC, HMI, and SCADA

Before use, check the Modbus communication interface, register map, device address, baud rate, and parity from the device manual you ordered

Power Supply

The referenced sub-model DN80 uses an AC 85-250 V power supply, and the voltage should be checked from the nameplate before connecting

The SG-QTLD Series also has DC power supply options for some models, so do not use voltage data from other sub-models without verification

IP65 Protection Rating

The referenced Compact Type sub-model DN80 has an IP65 protection rating, which is suitable for industrial applications requiring dust and water protection according to standard conditions

Proper installation and sealing of the wiring entry should be carried out, as well as avoiding environments exceeding the device's protection rating.

Installation in Piping Systems (Installation)

The Electromagnetic Flow Meter should be installed in a position where the pipe is fully filled with liquid during measurement. Avoid locations where air bubbles may accumulate or areas where the liquid may not fully fill the pipe.

The straight pipe lengths before and after the meter should be checked according to the manufacturer's manual, and the Grounding and Electrical Bonding systems should be installed appropriately to reduce the impact of electrical noise signals.

Application Examples (Applications)

  • Water supply and water distribution systems
  • Wastewater treatment systems
  • Pumping and water circulation systems
  • Flow measurement systems in industrial factories
  • Systems for measuring conductive water or liquids
  • Production process control systems
  • PLC and HMI systems for flow measurement
  • SCADA and Process Monitoring systems
  • Factory Automation and Process Control systems

Installation Precautions (Installation Precautions)

  • Check the pipe size DN80 and flange standard
  • Check the conductivity of the liquid
  • Select suitable Liner and Electrode materials for the medium
  • Check the operating voltage and temperature
  • Install in a location where the liquid fully fills the pipe cross-section
  • Avoid locations where air bubbles may accumulate
  • Ensure the straight pipe length according to the manufacturer's manual
  • Check Grounding and Electrical Bonding
  • Separate signal wires from power wires that may cause interference
  • Check the power supply voltage to match the Nameplate
  • Set the output signal and communication system correctly
  • Relieve pressure and disconnect the power supply before disassembly or maintenance

Important Notes Before Ordering (Important Notes)

  • The product is an Electromagnetic Flow Meter from brand SANGI, model SG-QTLD-DN80
  • Pipe size DN80 or approximately 3 inches
  • Used for conductive liquids
  • Confirm the full model number before determining the Liner and Electrode materials
  • Check the flange standard and pressure rating
  • Check the power supply voltage and output signal
  • Confirm the Modbus communication or other required protocol
  • Check the installation size and Face-to-Face distance from the Dimension Drawing
  • Verify the calibration documents and warranty conditions before ordering
  • Do not use the data of SG-QTLD/S Hygienic Type in place of the standard SG-QTLD model
  • Write Your Own Review
    You're reviewing:SG-QTLD-DN80 Electromagnetic Flow Meter SANGI
    Cookie settings
    🤖 AI Assistant
    Ask about products, specs and replacement models
    Hello 👋 Ask us anything — find products, compare specs, or troubleshoot.
    🗑 Clear history