ELECTROMAGNETIC FLOW METER SANGI SG-QTLD-DN65 (Electromagnetic Flow Meter)
SANGI SG-QTLD-DN65 is an Electromagnetic Flow Meter in the SG-QTLD Series, designed for measuring flow rates of electrically conductive liquids. It is suitable for use in water supply systems, wastewater treatment systems, water distribution systems, and industrial production processes.
The SG-QTLD-DN65 model has a pipe size of DN65 or approximately 2½ inches. It uses the principle of electromagnetic induction to measure the velocity of liquids inside the pipe, then calculates and displays the flow rate or sends data to control systems based on selected device functions.
Measurement using Electromagnetic Induction does not involve rotating blades or moving parts in the flow path, reducing wear issues compared to some mechanical flow meters. It is ideal for measuring electrically conductive liquids.
The SG-QTLD Series offers output signal options of 4-20mA and Pulse, as well as communication protocols such as Modbus-RS485, HART, or Profibus depending on the model. These can be integrated with PLCs, HMIs, SCADA systems, and other production control systems that support them.
Features
- SANGI brand Flow Meter
- SG-QTLD-DN65 model in SG-QTLD Series
- Type: Electromagnetic Flow Meter
- Pipe size DN65 or approximately 2½ inches
- Metering principle: Electromagnetic Induction
- Suitable for electrically conductive liquids
- No rotating blades inside the flow path for measurement
- Flow velocity range of Series: 0.1-15 m/s
- Standard accuracy of Series: ±0.5%
- Accuracy options available: ±0.3% and ±0.2%
- Power supply options: AC and DC
- Analog output option: 4-20mA
- Pulse output option
- Communication protocol options: Modbus-RS485, HART, Profibus
- Supports integration with PLC, HMI, SCADA systems depending on sub-model
- Suitable for water systems, wastewater treatment systems, and process control applications
Technical Specifications
| Specifications |
Details |
| Brand |
SANGI |
| Model |
SG-QTLD-DN65 |
| Series |
SG-QTLD |
| Product Type |
Electromagnetic Flow Meter |
| Measuring Principle |
Electromagnetic Induction |
| Nominal Pipe Size |
DN65 (2½ Inch) |
| Measured Medium |
Electrically Conductive Liquids |
| Series Pipe Size Range |
DN3-DN3000 mm |
| Series Flow Velocity Range |
0.1-15 m/s |
| Standard Accuracy |
±0.5% (Series Specification) |
| Optional Accuracy |
±0.3% / ±0.2% (Depending on Configuration) |
| Minimum Liquid Conductivity |
>5 µS/cm |
| Demineralized Water Conductivity |
>20 µS/cm |
| Series Medium Temperature |
-20 to +180 °C (Depending on Materials and Configuration) |
| Working Pressure Options |
16 / 25 / 40 / 63 bar (Selection Required) |
| Power Supply Options |
85-250 VAC / 20-36 VDC |
| Analog Output Option |
4-20mA |
| Pulse Output Option |
Available |
| Communication Options |
Modbus-RS485 / HART / Profibus |
| Protection Options |
IP65 / IP68 (Remote Configuration) |
| Installation Structure |
To Be Confirmed from Full Model Code |
| Liner Material |
To Be Confirmed Before Ordering |
| Electrode Material |
To Be Confirmed Before Ordering |
| Body Material |
To Be Confirmed Before Ordering |
| Flange Standard |
To Be Confirmed Before Ordering |
| Face-to-Face Dimension |
Refer to Manufacturer Dimension Drawing |
| Full Configuration Code |
Required for Exact Product Specifications |
Note on Data: The operating pressure, temperature, power supply, output signal, communication and protection level shown in the table are SG-QTLD Series data which have different options according to order. Therefore, full model code must be checked before confirming the specifications of the actual sold SG-QTLD-DN65.
Working Principle of Electromagnetic Flow Meter
The Electromagnetic Flow Meter operates based on Faraday's Law of Electromagnetic Induction. When electrically conductive liquid flows through a magnetic field inside the measuring pipe, an electrical voltage is generated that is proportional to the flow velocity of the fluid.
Electrodes within the meter detect the generated voltage and send signals into processing circuits for calculating flow rate. The system can display or transmit data to external control devices according to selected features in sub-models.
This technology has no rotating blades inside the flow path, reducing maintenance related to rotating parts, and is suitable for systems requiring continuous flow measurement.
Pipe Size DN65 (Nominal Pipe Diameter)
The SG-QTLD-DN65 is a pipe size DN65 or approximately 2½ inches meter, suitable for installation in piping systems with sizes and connection standards matching the meter.
Before installation, flange standard, mounting hole spacing, thread size, and flange pressure rating must be checked from the manufacturer's Dimension Drawing as DN65 equipment with different flange standards may not be directly interchangeable.
Flow Measurement Range
The SG-QTLD Series specifies a flow velocity range of 0.1-15 m/s, which can be used for initial meter size and operating range selection.
The actual flow rate range depends on the internal cross-sectional area of the measuring pipe and instrument measurement range setting. Therefore, it is advisable to check the system's minimum flow rate, normal flow rate, and maximum flow rate before selecting usage.
Check the calibration range and accuracy as certified by the manufacturer, especially for applications requiring low flow measurement or significant changes in flow rate.
Measurement Accuracy
The SG-QTLD Series specifies standard accuracy of ±0.5% and offers options of ±0.3% or ±0.2%, depending on the model ordered.
For high-precision applications, verify calibration documents, measurement range, and testing conditions provided by the manufacturer to ensure accuracy matches actual usage requirements.
Liquid Conductivity
The SG-QTLD Series is designed for measuring liquids with electrical conductivity, specifying a minimum of 5 µS/cm for liquid conductivity and over 20 µS/cm for Demineralized Water.
It is not suitable for non-conductive liquids such as fuel oil, lubricating oil, and general hydrocarbons due to the principle of electromagnetic induction requiring electrical conductivity in the medium.
Analog Output 4-20mA
The SG-QTLD Series offers an Analog Output 4-20mA option for transmitting flow rate values to PLCs, HMIs, Data Loggers, or production control systems that support standard current signals.
Before connecting, check the output type, wiring method, and scaling settings to match the measurement range specified in the meter.
Pulse Output
The SG-QTLD Series provides a Pulse Output option for sending pulse signals to counting devices or control systems to calculate cumulative flow volume based on set Pulse Scaling values.
Check signal type, voltage level, maximum frequency, and wiring requirements from the sub-model manual before use.
Modbus-RS485 Communication
The SG-QTLD Series supports Modbus-RS485 communication options for connecting flow data to PLCs, HMIs, SCADA systems, and other control devices that support the same protocol.
When using this feature, verify that the ordered SG-QTLD-DN65 model has an RS485 port and check device address, baud rate, parity, stop bit, and Modbus register map settings according to the manufacturer's manual.
HART and Profibus Communication Options
The SG-QTLD Series offers HART and Profibus communication options for industrial process control systems that support them. Specify the desired protocol during equipment selection.
Support for various protocols does not mean that all devices come with every communication installed together.
Liner and Electrode Materials
Selecting the Liner and Electrode materials is a crucial factor for using an Electromagnetic Flow Meter because these components directly contact the fluid being measured.
The material should be chosen based on the type of liquid, chemical concentration, temperature, pressure, and corrosion. This can be verified from the full model number and manufacturer's technical documentation.
For SG-QTLD-DN65, the types of Liner and Electrode installed in sub-models have not been confirmed yet, so it is advisable to check before using with corrosive chemicals or liquids.
Power Supply
The SG-QTLD Series offers power supply options of 85-250 VAC or 20-36 VDC depending on the model specification. Users must verify the rated voltage from the nameplate before connecting the power source.
Do not connect AC power to a model designed for DC, or vice versa, as this may damage the equipment.
Protection Degree
The SG-QTLD Series offers protection levels of IP65 and IP68 for Remote models based on selected conditions.
Select the appropriate protection level according to the environment such as indoor spaces, wet areas, or sumps. Ensure proper sealing at connections and signal cables in accordance with the manual.
Installation in Pipe Systems
Meters should be installed in positions where pipes are full cross-sections during measurement and avoid points that may accumulate air bubbles or cause non-full pipe flow conditions as these can affect measurement accuracy.
Check the straight pipe lengths before and after the meter from the manufacturer's manual, and install proper Grounding and Electrical Bonding systems to help reduce electrical interference effects.
Application Examples
- Potable water and water supply systems
- Sewage treatment systems
- Pumping stations and pumps
- Water circulation in industrial plants
- Flow measurement in production processes
- Pipe systems for conductive liquids
- PLC and HMI flow rate monitoring systems
- SCADA data logging and tracking systems
- Factory Automation and Process Control Systems
Installation Precautions
- Check the pipe size DN65 and flange standard before installation
- Ensure that the liquid's electrical conductivity is appropriate
- Select the Liner material and Electrode to match the medium
- Verify that the fluid pressure and temperature do not exceed ratings
- Install with full pipe cross-section during measurement
- Avoid locations where air bubbles accumulate
- Ensure straight pipe runs as per manufacturer's specifications
- Check Grounding and Electrical Bonding
- Separate signal wires from power lines that may have interference
- Verify the supply voltage matches the Nameplate rating
- Check Analog Output, Pulse Output, and Communication settings
- Cut off power and relieve pipe pressure before removal or maintenance
Important Notes Before Purchase (Important Notes)
- The product is an Electromagnetic Flow Meter by SANGI model SG-QTLD-DN65
- Pipe size DN65 or approximately 2½ inches
- For liquids with specified electrical conductivity values
- Must confirm full model number to determine installation type
- Must specify Liner and Electrode materials
- Must specify flange standard and pressure rating
- Must select power supply suitable for the system
- Must confirm output signal and communication protocol
- Check mounting size and Face-to-Face distance from Drawing
- Review calibration documents and warranty conditions before purchase