SANGI SG-QTLD-DN50 Electromagnetic Flow Meter
SANGI SG-QTLD-DN50 is an electromagnetic flow meter in the SG-QTLD Series designed for measuring the flow rate of electrically conductive liquids. It is suitable for use in water supply systems, wastewater treatment systems, water distribution systems, and industrial production processes.
The SG-QTLD-DN50 model is used with pipe sizes DN50 or approximately 2 inches, utilizing electromagnetic induction principles to measure the velocity of liquid inside the pipe. The detected signals are then calculated into flow rate and cumulative flow volume according to the meter's functions.
Measurement using Electromagnetic Induction does not involve rotating blades or mechanical parts in the flow path, thus reducing wear issues compared to some mechanical meters, and is suitable for liquids with sufficient electrical conductivity.
The compact type variant of SG-QTLD-DN50 found in SCMA listings features an integrated display unit with Neoprene (CR) liner material, Stainless Steel 316L electrodes, and Cast Iron pipe body. It supports 4-20mA signals, Pulse output, and Modbus communication.
Material details, power supply sources, and flange standards must be verified against the full model code as SG-QTLD Series offers multiple options for use in different environmental and production conditions.
General Features (Features)
- SANGI flow meter
- SG-QTLD-DN50 model in the SG-QTLD Series
- Type: Electromagnetic Flow Meter
- Pipe size DN50 or approximately 2 inches
- Measurement using Electromagnetic Induction principle
- Suitable for liquids with sufficient electrical conductivity as per specifications
- No rotating blades in the flow path
- Flow velocity range of Series: 0.1-15 m/s
- Standard accuracy ±0.5%
- Accuracy options available at ±0.3% or ±0.2%
- Compact and Remote display unit options depending on the model
- Suitable for 4-20mA signal option
- Pulse output option supported
- Modbus-RS485 communication option supported
- Fits applications with compatible PLC, HMI, and SCADA systems
- Suitable for water supply systems, wastewater treatment systems, and process control applications
Technical Specifications
| Specifications | Details |
| Brand | SANGI |
| Model | SG-QTLD-DN50 |
| Series | SG-QTLD |
| Product Type | Electromagnetic Flow Meter |
| Measuring Principle | Electromagnetic Induction |
| Nominal Pipe Size | DN50 (2 Inch) |
| Measured Medium | Electrically Conductive Liquids |
| Series Flow Velocity Range | 0.1-15 m/s |
| Standard Accuracy | ±0.5% (Series) |
| Optional Accuracy | ±0.3% / ±0.2% |
| Minimum Liquid Conductivity | >5 µS/cm |
| Demineralized Water Conductivity | >20 µS/cm |
| Series Medium Temperature | -20 to +180 °C (Depending on Configuration) |
| Reference Medium Temperature | -10 to +80 °C (Neoprene Configuration) |
| Reference Maximum Working Pressure | 1.6 MPa |
| Reference Structure | Compact Type |
| Reference Liner Material | Neoprene (CR) |
| Reference Electrode Material | Stainless Steel 316L |
| Reference Body Material | Cast Iron |
| Reference Flange Options | DIN PN10 / PN16 / PN25 / PN40 |
| Reference Power Supply | AC 85-250 V |
| Reference Analog Output | 4-20mA |
| Reference Pulse Output | Available |
| Reference Communication | Modbus |
| Reference Protection Degree | IP65 |
| Full Reference Model | SG-QTLD-DN50(2")-S1-P3-L4-E1-K1-F3-D1-G1-G2-C4-F1 |
| Exact Product Configuration | To Be Confirmed Before Ordering |
Note: The information on Liner Neoprene, Electrode SS316L, Housing Cast Iron, Power Supply 85-250VAC, Maximum Pressure 1.6 MPa and IP65 is specific to the sub-model DN50 published by SCMA. It should not be used to confirm features of all SG-QTLD-DN50 models without verifying the full model code.
Working Principle of Electromagnetic Flow Meter
The Electromagnetic Flow Meter operates based on Faraday's Law of Electromagnetic Induction, where when an electrically conductive fluid flows through a magnetic field inside the measuring pipe, it generates an electrical voltage proportional to the flow velocity.
Internal electrodes detect the generated electrical signal and send it to the processing circuit for calculation as liquid flow rate. The measured value depends on the pipe size, flow speed, and meter settings.
Pipe Size DN50 (Nominal Pipe Diameter)
The SG-QTLD-DN50 is designed for installation with a DN50 or approximately 2-inch nominal pipe diameter system. It's necessary to select matching flange standards and Pressure Rating according to the actual pipeline.
Sub-models referenced from SCMA have standard flange options DIN PN10, PN16, PN25, and PN40 which must be clearly specified before ordering as identical DN50 meters may not be interchangeable if their flange standards differ.
Flow Velocity Range
The SG-QTLD Series specifies a flow velocity range of 0.1-15 m/s for selecting the meter according to fluid flow characteristics.
Meter sizing should consider minimum, normal and maximum flow rates to ensure the meter operates within its specified performance range as per manufacturer's requirements.
Measurement Accuracy
The SG-QTLD Series has a standard accuracy of ±0.5% with options for ±0.3% or ±0.2% based on model specification and calibration conditions.
For high-accuracy applications, it is advisable to check the Calibration Certificate and verified measurement range before putting the equipment into service.
Liquid Conductivity
SG-QTLD Series is suitable for liquids with a conductivity value greater than 5 µS/cm and for Demineralized Water, specifying values above 20 µS/cm.
It is not suitable for measuring non-conductive liquids such as fuel oil, lubricating oil, or general hydrocarbons.
Neoprene Liner (CR)
The sub-model SG-QTLD-DN50 found in SCMA uses Neoprene (CR) material Liner which is specified to be suitable for consideration with wastewater or liquids containing high sediment under the conditions of use of the material.
This information specifies a liquid temperature range of -10 to +80 °C, and it must be verified that the material is compatible with the actual liquid before selecting its use.
Stainless Steel 316L Electrode
The referenced sub-model uses Stainless Steel 316L material Electrode which is the fluid contact part for receiving measurement signals from the electric field.
It should be verified that SS316L material has chemical compatibility with the type of liquid, temperature, and concentration of chemicals before use, especially corrosive liquids.
4-20mA Output Signal
The referenced sub-model DN50 supports Analog Output 4-20mA for sending flow rate data to PLC, HMI, Data Logger, and control systems that support the standard signal.
The connection should be verified with the type of output and Scaling value matching the specified flow rate range in the meter.
Pulse Output
The referenced sub-model DN50 supports Pulse Output for sending pulse signals to liquid volume counting systems, requiring verification of wiring patterns and Pulse Scaling values from the manufacturer's manual.
Modbus Communication
The referenced sub-model DN50 supports Modbus for sending flow rate data to PLC, HMI, or SCADA systems that support the same protocol.
Before use, it must be verified with Modbus Register Map, Device Address, Baud Rate, Parity, and communication wiring patterns according to the actual equipment manual.
Power Supply
The referenced sub-model DN50 from SCMA supports AC 85-250 V power supply, and it must be verified with rated voltage from the nameplate before powering on.
SG-QTLD Series has other power supply options depending on model specifications; therefore, it should not be assumed that all SG-QTLD-DN50 units use the same type of power supply.
IP65 Protection Level
The DN50 Compact Type sub-model refers to the IP65 protection level, which is suitable for environments requiring dust and water resistance according to standard test conditions.
Proper installation and sealing of cable connections must be ensured, as well as checking manufacturer specifications when installing in wet or high-pressure washing areas.
Pipe System Installation (Installation)
The Electromagnetic Flow Meter should be installed at a position where the pipe is fully filled with liquid during measurement, avoiding locations prone to air bubble accumulation or incomplete liquid flow.
Selection of installation positions must consider straight pipe lengths before and after the meter as per the manual, along with proper grounding and electrical bonding to help reduce interference signals in measurements.
Application Examples (Applications)
- Potable water systems and water supply systems
- Sewage treatment systems
- Liquid systems containing sediment according to liner material specifications
- Pumping and recirculation systems
- Flow rate measurement in industrial plants
- Conductive liquid pipeline systems
- PLC and HMI flow control systems
- Data logging with SCADA systems
- Automation and process control systems
Installation Precautions (Installation Precautions)
- Check the DN50 pipe size and flange standard
- Verify the conductivity of the liquid
- Select liner and electrode materials suitable for the medium
- Check maximum operating pressure and temperature
- Ensure full pipe cross-section with liquid during measurement
- Avoid locations prone to air bubble accumulation
- Follow manufacturer guidelines for straight pipe lengths
- Verify grounding and electrical bonding systems
- Separate signal wires from power lines that may cause interference signals
- Check the power supply type according to the model received
- Properly set output signals and communication systems
- Purge pipe pressure before disassembly or maintenance of the meter
Important Notes Before Purchase (Important Notes)
- The product is an Electromagnetic Flow Meter, model SG-QTLD-DN50 by SANGI
- Pipe size DN50 or approximately 2 inches
- Suitable for conductive liquids
- Confirm full model code before selecting liner and electrode materials
- Check flange standards and pressure ratings
- Verify power supply type and voltage
Check the output signal and communication
Check Compact or Remote structure according to installation area
Check mounting size and Face-to-Face distance from Drawing
Calibration Certificate and warranty conditions should be checked before purchase
The data of SG-QTLD/S-DN50 Hygienic Type model should not be used as a substitute for the standard SG-QTLD-DN50 model