SANGI Electromagnetic Flow Meter Model SG-QTLD-DN40 (Electromagnetic Flow Meter)
SANGI SG-QTLD-DN40 is an electromagnetic flow meter (Electromagnetic Flow Meter) in the SG-QTLD Series, used for measuring the flow rate of conductive liquids, such as industrial water, wastewater, and process liquids that are suitable for the meter's material.
The SG-QTLD-DN40 model is used for DN40 pipe systems or approximately 1½ inches, utilizing the principle of electromagnetic induction to measure the velocity of the liquid inside the pipe and convert the measured signal into a flow rate value.
This type of meter has no impeller or rotating mechanical components in the flow path for measurement, making it suitable for measuring liquids in industrial piping systems that require reducing wear on moving parts and supporting continuous measurement when used and installed appropriately.
The SG-QTLD Series offers options such as Analog Output 4-20mA, Pulse Output, and communication protocols Modbus-RS485, HART, or Profibus according to the model specification. It can integrate flow data with PLC, HMI, SCADA, and production control systems that support these interfaces.
General Features (Features)
- SANGI flow meter
- Model SG-QTLD-DN40 in the SG-QTLD Series
- Type: Electromagnetic Flow Meter
- Pipe size: DN40 or approximately 1½ inches
- Measured using the principle of Electromagnetic Induction
- Suitable for conductive liquids according to specifications
- No rotating impeller in the flow path for measurement
- Flow velocity range of the Series: 0.1-15 m/s
- Standard accuracy: ±0.5%
- Optional accuracy: ±0.3% or ±0.2%
- Optional power supply: AC and DC
- Supports Analog Output 4-20mA
- Supports Pulse Output
- Supports Modbus-RS485, HART, and Profibus
- Can be integrated with PLC, HMI, and SCADA
- Suitable for water supply systems, wastewater treatment systems, and process control systems
Technical Specifications (Technical Specifications)
| Specifications | Details |
| Brand | SANGI |
| Model | SG-QTLD-DN40 |
| Series | SG-QTLD |
| Product Type | Electromagnetic Flow Meter |
| Measuring Principle | Electromagnetic Induction |
| Nominal Pipe Diameter | DN40 (1½ Inch) |
| Measured Medium | Electrically Conductive Liquids |
| Series Pipe Size Range | DN3-DN3000 mm |
| Series Flow Velocity Range | 0.1-15 m/s |
| Standard Accuracy | ±0.5% (Series) |
| Optional Accuracy | ±0.3% / ±0.2% |
| Minimum Liquid Conductivity | >5 µS/cm |
| Demineralized Water Conductivity | >20 µS/cm |
| Series Medium Temperature | -20 to +180 °C (Depending on Selected Configuration) |
| Working Pressure Options | 16 / 25 / 40 / 63 bar (Selection Required) |
| Power Supply Options | 85-250 VAC / 20-36 VDC |
| Output Signal Options | 4-20mA / Pulse |
| Communication Options | Modbus-RS485 / HART / Profibus |
| Protection Options | IP65 / IP68 (Remote Configuration) |
| Installation Structure | Compact or Remote (Depending on Configuration) |
| Liner Material | To Be Confirmed from Full Model Code |
| Electrode Material | To Be Confirmed from Full Model Code |
| Body Material | To Be Confirmed from Full Model Code |
| Connection Standard | To Be Confirmed Before Ordering |
| Face-to-Face Dimension | Refer to Manufacturer Drawing |
| Full Configuration Code | Required for Exact Specifications |
Important Note: Operating voltage, power supply, temperature range, output signal, and communication are optional data of the SG-QTLD Series. Please check the full model code before confirming whether the ordered product SG-QTLD-DN40 supports which features.
Working Principle of Electromagnetic Flow Meter
The Electromagnetic Flow Meter operates according to Faraday's Law of Electromagnetic Induction, by creating a magnetic field through the measuring tube where conductive liquid flows.
When the liquid flows through the magnetic field, an electromotive force related to the flow velocity is generated. The electrodes of the meter detect the signal and send it to the processing circuit to calculate the liquid flow rate.
Measurement using this principle does not require a rotating impeller in the flow path, thus reducing the risk of wear on rotating components compared to some mechanical meters.
Pipe Size DN40 (Nominal Pipe Diameter)
SG-QTLD-DN40 is the DN40 pipe size model, or approximately 1½ inches, suitable for installation in piping systems with sizes and connection standards matching the meter.
Before installation, check the type of connection, flange standard, bolt hole spacing, and pressure rating, as pipes or equipment with the same DN40 size may have different connection standards.
Flow Measurement Range
The SG-QTLD Series data specifies a flow velocity range of 0.1-15 m/s, which can be used to consider the meter size and operating range.
The measurable flow rate depends on the internal cross-sectional area of the measuring tube and the liquid velocity. The actual measurement range should be checked from the Datasheet and the settings of the ordered model.
When selecting the meter, consider the minimum, normal, and maximum flow rates to ensure that the usage is within the range specified by the manufacturer.
Measurement Accuracy
The SG-QTLD Series has a standard accuracy of ±0.5%, and options of ±0.3% or ±0.2% are available depending on the model and calibration conditions.
For applications requiring high accuracy, such as process control or quality reporting, check the guaranteed error value and calibration documents before actual use.
Liquid Conductivity
SG-QTLD Series is suitable for liquids with conductive properties, as the catalog data specifies a conductivity value greater than 5 µS/cm, and for demineralized water it must be greater than 20 µS/cm
Not suitable for non-conductive liquids such as fuel oil, lubricating oil, and general hydrocarbon liquids, because it is not possible to generate a measurement signal according to the principle required by the device
4-20mA Signal Output (Analog Output)
SG-QTLD Series has a 4-20mA signal option to send flow rate data to control devices such as PLC, HMI, or Data Logger that support standard current input
Before use, check the output type, wiring, and scaling value to ensure they are compatible with the meter's measurement range
Pulse Output
SG-QTLD meter has a Pulse Output option to send pulse signals according to the specified flow volume, suitable for liquid accumulation counting systems or signal reception through High-Speed Input and Pulse Counter of compatible PLCs
Before connecting, check the pulse type, voltage rating, and pulse scaling value from the sub-model manual
Modbus-RS485 Communication
SG-QTLD Series supports the Modbus-RS485 communication option to send data from the flow meter to PLC, HMI, SCADA, or external control systems
Usage requires checking that the ordered model has an RS485 port and setting the Device Address, Baud Rate, Parity, and Register Map to match the device manual
HART and Profibus Communication Options
SG-QTLD Series has HART and Profibus communication options according to the order, which is suitable for use with process control systems that support these protocols
These protocols are options and should not be assumed to be available in all functions of every meter
Liner and Electrode Materials
Selecting Liner and Electrode materials is an important factor for using an Electromagnetic Flow Meter, as these are the parts that come into contact with the liquid inside the system
Choose materials suitable for the chemical properties, temperature, pressure, and concentration of the liquid, and check the materials specified in the full product code before ordering
Power Supply
SG-QTLD Series has power supply options of 85-250 VAC or 20-36 VDC according to the model specification
Check the supply voltage indicated on the meter's nameplate before powering on. Do not connect an AC power source to a DC model or vice versa.
Protection Degree
The SG-QTLD Series has options of IP65 and IP68 for remote installation according to the manufacturer's model specifications and conditions.
Select the appropriate IP level according to the installation environment and ensure that the cable connectors are sealed properly and the wiring method is correct.
Installation
Install the meter in a position where the liquid fills the cross-section of the pipe during measurement, and avoid positions where air bubbles may accumulate or where the flow is not fully filled in the pipe.
When selecting the installation position, consider the straight pipe lengths before and after the meter, as well as grounding and electrical connection of the liquid according to the manufacturer's manual.
Applications
- Industrial water supply systems
- Water supply and pumping systems
- Wastewater treatment systems
- Water circulation systems in machinery
- Conductive liquid pipeline systems
- Flow rate measurement systems in production processes
- PLC and HMI systems for flow measurement
- SCADA and Process Monitoring systems
- Factory Automation and Process Control systems
Installation Precautions
- Check the pipe size DN40 and the connection standard
- Check the conductivity of the liquid before use
- Check that the liner and electrode materials are compatible with the medium
- Check the maximum temperature and operating pressure
- Install in a position where the pipe is fully filled with liquid
- Avoid areas where air bubbles may accumulate
- Provide straight pipe lengths according to the manufacturer's manual
- Check the grounding and electrical bonding system
- Separate signal wiring from power lines and noise sources
- Ensure the power supply matches the nameplate
- Check the settings for Analog Output, Pulse Output, and Modbus
- Turn off the power supply and release the pressure in the pipe before disassembly or maintenance
Important Notes
- The product is an Electromagnetic Flow Meter from brand SANGI, model SG-QTLD-DN40
- Pipe size DN40 or approximately 1½ inches
- Suitable for conductive liquids
Verify the Compact or Remote type according to the full model code
Select the Liner and Electrode materials suitable for the liquid
Check the connection standard and pressure rating
Confirm the power supply type, AC or DC
Check the required Output and Communication functions
Check the installation size and Face-to-Face distance from the Drawing
Check the calibration documents and warranty conditions before ordering
The SG-QTLD-DN40 model has a different standard from the SG-QTLD/S-DN40 Hygienic Type