SANGI SG-QTLD-DN25 Electromagnetic Flow Meter (Electromagnetic Flow Meter)
SANGI SG-QTLD-DN25 is an electromagnetic flow meter in the SG-QTLD Series, designed for measuring the flow rate of electrically conductive liquids such as industrial water, wastewater, and process fluids that are suitable for the material specifications.
The SG-QTLD-DN25 model is used for DN25 pipe systems (approximately 1 inch) by utilizing electromagnetic induction principles to measure the velocity of fluid inside the pipe and then converting the measured signal into flow rate.
This type of meter does not have rotating blades or mechanical parts in the flow path, making it suitable for measuring fluids in properly designed and installed pipeline systems.
The SG-QTLD Series offers output signal options such as 4-20mA, Pulse, and communication protocols like Modbus-RS485, HART, or Profibus depending on the model. Data from this meter can be used in PLC, HMI, SCADA, and process control systems based on installed functions.
Features
- SANGI brand flow meter
- SG-QTLD-DN25 model in SG-QTLD Series
- Type: Electromagnetic Flow Meter
- For DN25 pipe systems (1 inch)
- Metering by electromagnetic induction principle
- Suitable for liquids with specified electrical conductivity values
- No rotating blades in the flow path
- Flow velocity range of Series: 0.1-15 m/s
- Standard accuracy of Series: ±0.5%
- Precision options available at ±0.3% or ±0.2%
- AC or DC power supply options
- Analog output option: 4-20mA
- Pulse output option
- Communication protocol options: Modbus-RS485, HART, and Profibus
- Compatible with PLC, HMI, and SCADA systems that support it
- Suitable for water supply systems, wastewater treatment, and process control applications
Technical Specifications
| Specifications | Details |
| Brand | SANGI |
| Model | SG-QTLD-DN25 |
| Series | SG-QTLD |
| Product Type | Electromagnetic Flow Meter |
| Measuring Principle | Electromagnetic Induction |
| Nominal Diameter | DN25 (1 Inch) |
| Measured Medium | Electrically Conductive Liquids |
| Series Pipe Size Range | DN3-DN3000 mm |
| Series Flow Velocity Range | 0.1-15 m/s |
| Standard Accuracy | ±0.5% (Series) |
| Optional Accuracy | ±0.3% / ±0.2% |
| Minimum Liquid Conductivity | >5 µS/cm |
| Demineralized Water Conductivity | >20 µS/cm |
| Series Medium Temperature | -20 to +180 °C (Depending on Configuration) |
| Working Pressure Options | 16 / 25 / 40 / 63 bar (Selection Required) |
| Power Supply Options | 85-250 VAC / 20-36 VDC |
| Output Signal Options | 4-20mA / Pulse |
| Communication Options | Modbus-RS485 / HART / Profibus |
| Protection Options | IP65 / IP68 (Remote Configuration) |
| Installation Type | Depends on Selected Configuration |
| Liner Material | To Be Confirmed from Full Model Code |
| Electrode Material | To Be Confirmed from Full Model Code |
| Body Material | To Be Confirmed from Full Model Code |
| Flange Standard | To Be Confirmed Before Ordering |
| Face-to-Face Dimension | Refer to Manufacturer Drawing |
| Full Configuration Code | Required for Exact Specifications |
Note on Data: The accuracy values, power supply, temperature range, operating pressure, output signal, and communication options in the table are data and choices for SG-QTLD Series. Please check the full model code to confirm which features the ordered SG-QTLD-DN25 product supports.
Working Principle of Electromagnetic Flow Meter
The Electromagnetic Flow Meter operates based on Faraday's Law of Electromagnetic Induction by creating a magnetic field through the measuring pipe where electrically conductive liquid flows.
When the liquid moves through the magnetic field, an electrical voltage is generated that is proportional to the flow velocity. The electrodes inside the meter detect this signal and send it to the processing circuit for calculation and display as the fluid flow rate.
This measurement method has no rotating impeller in the flow path, thus reducing wear issues compared to some mechanical flow meters.
Pipe Size DN25 (Nominal Pipe Diameter)
SG-QTLD-DN25 is the code for a meter with a pipe size of DN25 or nominal diameter 1 inch. It is suitable for installation in piping systems that match the meter's size and flange standards.
Before installation, check the flange standard, mounting hole spacing, rated pressure, and face-to-face distance of the meter because similar-sized equipment may use different connection standards.
Flow Measurement Range
The SG-QTLD Series specifies a flow velocity range of 0.1-15 m/s for selection purposes. The actual flow rate range of the meter depends on pipe size and manufacturer settings.
Selecting the measurement range should consider the minimum, normal, and maximum system flow rates to ensure the meter operates within an appropriate range.
Measurement Accuracy
The SG-QTLD Series has standard accuracy of ±0.5%, with options for ±0.3% or ±0.2% depending on model specifications.
For high-precision applications, verify the error margin, calibration conditions, and certified flow rate range before actual use.
Liquid Conductivity
The electromagnetic field-based flow meter is suitable for liquids with electrical conductivity. The SG-QTLD Series specifies a conductivity value greater than 5 µS/cm, and for demineralized water, it specifies a value greater than 20 µS/cm.
Not suitable for non-conductive liquids such as fuel oil, lubricating oil, and general hydrocarbons because it cannot generate an appropriate measurement signal according to the principle required by the instrument.
Analog Output 4-20mA (Analog Output)
The SG-QTLD Series offers a 4-20mA Analog Output option for sending flow rate values to PLC, HMI, Data Logger or external control systems that support it
It is necessary to check the output type, wiring and scaling settings according to the specified flow range of the system.
Pulse Output
The SG-QTLD meter offers a Pulse Output option for sending pulse signals to counting devices or external control systems. It can be used to process cumulative flow volume based on the defined Pulse Scaling value.
Usage requires checking the output type, maximum frequency, electrical rating and wiring characteristics from the manual of the actual ordered model.
Modbus-RS485 Communication
The SG-QTLD Series supports a Modbus-RS485 communication option for sending flow rate data to PLC, HMI, SCADA or control devices that support the same protocol.
It is necessary to check whether the ordered model has RS485 Modbus function and verify Modbus Register Map, Device Address, Baud Rate, Parity and data format according to the manufacturer's manual before connecting.
HART and Profibus Communication Options
In addition to Modbus-RS485, the SG-QTLD Series also offers HART and Profibus communication options based on order requirements for compatibility with industrial process control systems using these protocols.
These protocols are optional and should not be assumed to be installed in every unit. It is necessary to check the full model code before ordering.
Liner and Electrode Materials
Selecting Liner and Electrode materials is crucial for Electromagnetic Flow Meters as these components directly contact the liquid being measured.
Material selection should be appropriate for the type of liquid, temperature, chemical concentration, and operating pressure by checking the sub-model material code before ordering.
Power Supply Selection
The SG-QTLD Series offers a power supply option of 85-250 VAC or 20-36 VDC according to model specification. It is necessary to check the rated voltage of the actual received equipment before connecting to the power source.
Do not apply AC voltage to models designed for DC power sources, or vice versa, as this may cause damage to the equipment.
Protection Degree
The SG-QTLD Series has IP65 protection degree and an option for IP68 in the Remote model based on order conditions.
Select a protection level that suits the installation area, such as indoor spaces, wet areas, or sumps. Also, check the manufacturer's specifications regarding wiring and sealing joints.
Installation in Pipe Systems
The meter should be installed at a position where there is always full pipe cross-section liquid during measurement, avoiding locations with air bubbles accumulation or partial flow conditions.
Check the straight pipe lengths before and after the meter from the manual of the selected model. Also, ensure proper Grounding and Electrical Bonding according to the manufacturer's requirements to reduce interference signals.
Application Examples
- Potable water systems and water distribution networks
- Sewage treatment systems
- Pump and circulation systems
- Flow rate measurement in industrial plants
- Tubing of conductive liquids
- Process flow monitoring
- PLC and HMI for flow rate measurement
- SCADA and Process Monitoring Systems
- Automation and Process Control Systems
Installation Precautions
- Check the pipe size DN25 and joint standards before installation.
- Verify that the liquid's conductivity is appropriate.
- Ensure compatibility between liner material and electrode with the liquid.
- Inspect actual operating voltage and temperature.
- Install in a position where there is always full pipe cross-section liquid.
- Avoid locations with air bubbles accumulation.
- Follow manufacturer's manual for straight pipe lengths.
- Check grounding and signal wiring.
- Verify power supply voltage before powering the device.
- Set Analog Output and Pulse Output measurement ranges correctly.
- Check Modbus-RS485 communication according to the manual.
- Cut off power supply and release pressure in pipes before disassembly or maintenance.
Important Notes Before Ordering
- The product is an Electromagnetic Flow Meter brand SANGI model SG-QTLD-DN25.
- Pipe size DN25 or approximately 1 inch.
- Suitable for measuring flow rates of conductive liquids.
- Check the full model code to confirm Compact or Remote type.
Must select the appropriate Liner and Electrode type for the fluid
Must specify the operating pressure and flange standard
Must indicate AC or DC power supply according to the selected model
Must confirm output signal and communication protocol before ordering
Check installation size and Dimension Drawing before actual installation
Should review calibration documentation and warranty conditions before ordering