SANGI ELECTRIC RS232 to RS485 Converter Model RS-100B
The SANGI ELECTRIC RS-100B Converter is a communication signal converter between RS232 and RS485, designed for connecting control devices, machinery, and communication systems in industrial applications. It supports 2-wire RS485 and half-duplex data transmission.
The device features optical isolation circuitry between the input and output sides, which helps to isolate the communication circuits between devices and reduce the impact of electrical potential differences or interference that may occur within the system. The effectiveness of this protection depends on installation conditions and manufacturer specifications.
RS-100B supports multi-drop communication management for connecting multiple devices on an RS485 network, with a maximum device count of 256 units as specified in the catalog. It is suitable for use in automatic control systems, measurement systems, and serial communication devices in industrial plants.
General Features
- Brand: SANGI ELECTRIC
- Product Model: RS-100B
- Product Type: RS232 to RS485 Converter
- Converts signals between the RS232 and RS485 interfaces
- Suitable for 2-Wire RS485
- Specifies 2-Channel RS485 according to catalog information
- Supports half-duplex communication mode
- Features optical isolation between input and output sides
- Supports multi-drop network connection
- A maximum of 256 devices on the network as per catalog data
- Powers with 110VAC or 220VAC ±10%
- Suitable for communication systems and automatic control systems in industrial applications
Technical Specifications (Technical Specifications)
| Brand | SANGI ELECTRIC |
| Model | RS-100B |
| Product Type | RS232 to RS485 Converter |
| Communication Interface | RS232 / RS485 |
| RS485 Connection | 2-Wire, 2-Channel (Catalog Reference) |
| Communication Mode | Half Duplex |
| Signal Isolation | Optical Isolation between Input and Output |
| Network Configuration | Multi-drop |
| Maximum Connected Devices | Up to 256 Devices (Catalog Reference) |
| Power Supply | 110 / 220 VAC ±10% |
| Communication Standard | RS232 / RS485 |
| Application | Industrial Serial Communication |
Functionality
The RS-100B Signal Converter serves to convert the signal level and format of RS232 signals into Differential RS485 signals, allowing data transmission over an RS485 network. It also supports reverse signal conversion for receiving data from remote devices.
The 2-Wire RS485 system uses Half Duplex communication where each device shares the same pair of wires for both sending and receiving data, thus requiring management to prevent simultaneous transmissions on the bus.
Optical Isolation circuitry helps isolate electrical signals between input and output while a Multi-drop configuration allows multiple RS485 devices to be connected to the same communication system within the constraints of the device and network limitations.
Installation and Usage
- Check that the originating communication system uses an RS232 interface and that the remote device supports RS485.
- Verify the power supply voltage of the equipment matches either 110VAC or 220VAC before powering on.
- Connect the RS232 cable according to the pinout diagram specified in the manufacturer's manual.
- Connect the RS485 signal pair wires according to the terminal names and wiring diagrams of the equipment.
- Verify the correctness of the RS485 signal terminals as naming conventions A/B may differ by manufacturer.
- Rewire the RS485 with twisted-pair cables suitable for the installation environment.
- Position devices on a Multi-drop network and terminate lines with termination resistors according to system requirements.
- Configure communication parameters of originating and remote devices such as Baud Rate, Data Bits, Parity, and Stop Bits to match.
- Test data transmission and reception before putting the system into actual use.
Examples and Usage Guidelines
- Connect a computer with an RS232 port to an RS485 device.
- Use in conjunction with PLCs and control devices requiring communication interface conversion.
Connect multiple measuring devices through the RS485 Multi-drop network
Used in industrial machine monitoring and control systems
Applied in Monitoring and SCADA systems that use compatible serial communication interfaces
Used in automatic control systems requiring electrical signal isolation between devices
Considerations
- The RS-100B is an RS232 to RS485 converter, not a USB Converter or Ethernet Converter
- SUPPORTS RS485 Half Duplex; do not claim it as RS485 Full Duplex without confirmation data
- Maximum 256 devices according to the catalog, but consider the capabilities of all equipment and actual network design
- The 2-Channel information should be verified against pinout diagrams before wiring and channel usage determination
- Check power supply voltage and selection method (110VAC or 220VAC) from the manual or unit label before connecting power
- Verify proper termination resistor and biasing use for RS485 network
- Check Baud Rate and maximum cable length from specific model manuals before system design
- Check connector type and unit size from specific model documents before installation
- Electrical system installation should be performed by a qualified person following safety measures