SANGI ELECTRIC PLC EXPLX3V-4DA (Analog Output Module)
SANGI ELECTRIC PLC EXPLX3V-4DA is an analog output expansion module for PLC-based automatic control systems. It supports 4 analog signal outputs and can be used to send control signals to external devices that accept voltage or current signals.
The module supports analog output signal ranges of -10 V to +10 V and 4-20 mA, according to the SCMA General Catalog Vol.5. It is suitable for controlling equipment that accepts analog commands such as speed control circuits, drive units, or process control devices with compatible input signals.
The EXPLX3V-4DA has a signal conversion resolution of 12 bit and an accuracy of ±1%, according to the catalog. The module operates on a supply voltage of 24 VDC ±10% and consumes a current of 55 mA.
It is suitable for Factory Automation, Machine Control, and Process Control systems that require additional analog signal output channels. Compatibility with the main PLC and wiring requirements must be verified before installation.
Features
- Brand: SANGI ELECTRIC
- Model: PLC EXPLX3V-4DA
- Type: Analog Output Module
- Supports 4 analog output channels
- Supports voltage output range of -10 V to +10 V
- Supports current output signal range of 4-20 mA
- Output resolution of 12 bit
- Accuracy ±1% for specified signal ranges
- Catalog specifies Normal Speed at 15 ms/channel
- Catalog specifies High Speed at 6 ms/channel
- Operates on supply voltage of 24 VDC ±10%
- Module current consumption: 55 mA
- Suitable for expanding analog output channels of compatible PLCs
- Adaptable to machine and industrial process control systems
Technical Specifications
| Specifications |
Details |
| Brand | SANGI ELECTRIC |
| Model | PLC EXPLX3V-4DA |
| Product Type | Analog Output Module |
| Number of Analog Outputs | 4 Channels |
| Voltage Output Range | -10 V to +10 V |
| Current Output Range | 4-20 mA |
| Output Resolution | 12 bit |
| Accuracy - Voltage Output | ±1% (-10 V to +10 V) |
| Accuracy - Current Output | ±1% (4-20 mA) |
| Normal Speed Listed | 15 ms/channel (Function to Be Confirmed) |
| High Speed Listed | 6 ms/channel (Function to Be Confirmed) |
| Module Supply Voltage | 24 VDC ±10% |
| Module Current Consumption | 55 mA |
| Maximum Voltage Output Load | Not Specified in Catalog |
| Current Output Load Resistance | Not Specified in Catalog |
| Electrical Isolation | Not Specified in Catalog |
| Dimensions | Not Specified in Catalog |
| Operating Temperature | Not Specified in Catalog |
| Compatible PLC Models | To Be Confirmed from Manufacturer Documentation |
| Catalog Reference | SCMA General Catalog Vol.5, D3-05 |
Note: The catalog confirms the number of output channels, signal voltage and current range, resolution, accuracy, and module supply voltage. However, the speed data of 15 ms/channel and 6 ms/channel must be verified from the Datasheet as the catalog uses input signal descriptions for the output module listings.
4 Analog Output Channels
The PLC EXPLX3V-4DA supports 4 analog output channels to send control values from the PLC system to external devices that support it.
Expanding the number of analog output channels allows the system to send control values to multiple points, but the channel configuration settings and usage of voltage or current signals must be verified according to the manufacturer's manual.
Voltage Signal Range -10 V to +10 V Supported
The module supports analog voltage signal transmission in the range of -10 V to +10 V as per the catalog data, suitable for devices designed to receive bipolar voltage control signals.
Before connecting to external equipment, it is advisable to check the input voltage range, load resistance, and signal reference point to ensure proper compatibility.
Supports 4-20 mA Current Signal
The EXPLX3V-4DA supports output current signals in the range of 4-20 mA, which is a commonly used signal format in industrial process control systems.
This can be applied to devices with 4-20 mA current input control by checking the wiring configuration and maximum load resistance supported by the module from the Datasheet.
Output Resolution 12 bit (12-bit Resolution)
The module has a signal conversion resolution of 12 bits for creating analog signals from PLC system control values. This resolution indicates the level of value segmentation within the specified range.
A 12-bit resolution does not directly equate to signal accuracy, as actual accuracy depends on output circuit characteristics, load conditions, and usage scenarios.
Accuracy ±1%
The catalog specifies an accuracy of ±1% for output voltage signals in the range of -10 V to +10 V and current signals at 4-20 mA.
Detailed calculation basis for accuracy such as percent of measurement span or full scale is not clearly specified, so it should be checked from the Datasheet if used in systems with specific accuracy requirements.
Speed Data Normal Speed and High Speed
| Catalog Description |
Value |
| Normal Speed | 15 ms/channel |
| High Speed | 6 ms/channel |
The catalog provides two speed values, 15 ms/channel and 6 ms/channel, but describes signal input response times. Since the EXPLX3V-4DA is an Analog Output module,
Therefore, it is advisable to check manufacturer documentation to confirm the meaning and conditions of these values before using them to define system speed performance.
Powder Supply 24 VDC ±10%
The EXPLX3V-4DA uses a power supply of 24 VDC ±10% with an operating current consumption of 55 mA as per the catalog data.
Power system design should consider the load of the module and other devices within the system, including checking the power connection method according to the manufacturer's manual.
Compatibility with PLC System
EXPLX3V-4DA is an Analog Output module for expanding the signal output channels of a PLC system. It's necessary to verify compatibility with the main CPU and limitations of the Expansion Module before installation.
The configuration settings, scaling setup, and connection to end devices should be checked to ensure correct signal transmission as per design specifications.
Application Examples (Applications)
- Analog control signal system from PLC
- Control systems for devices supporting -10 V to +10 V signals
- Control systems for devices supporting 4-20 mA signals
- Speed control of drive units with compatible analog input
- Production process control systems
- A system that expands Analog Output by 4 points
- Factory Automation and Machine Control Systems
- Design and development of industrial control systems
Comparison between EXPLX3V-4AD and EXPLX3V-4DA
| Specifications |
EXPLX3V-4AD |
EXPLX3V-4DA |
| Module Type | Analog Input | Analog Output |
| Number of Channels | 4 Inputs | 4 Outputs |
| Voltage Signal | -10 V to +10 V | -10 V to +10 V |
| Current Signal | 4-20 mA | 4-20 mA |
| Resolution | 12 bit | 12 bit |
| Accuracy Listed | ±1% | ±1% |
| Supply Voltage | 24 VDC ±10% | 24 VDC ±10% |
| Module Current | 55 mA | 55 mA |
EXPLX3V-4AD is used for receiving analog signals into the PLC, while EXPLX3V-4DA is used for sending analog signals from the PLC to external devices. Therefore, they cannot be interchanged based solely on signal range or number of channels.
Guidelines for Selecting PLC EXPLX3V-4DA
- Verify that the system requires 4 Analog Output channels
- Check the type of signals supported by end devices
- Confirm output range -10 V to +10 V or 4-20 mA
- Evaluate the load driving capability of outputs
Consider the 12-bit resolution suitable for control systems
Check the accuracy of ±1% and test conditions
Confirm output speed data from Datasheet
Verify power supply voltage at 24 VDC ±10%
Check compatibility with major PLC models
Review Wiring Diagram and output channel configuration format
Installation Precautions
- Ensure signal type (Voltage or Current) matches the end device requirements
- Avoid connecting loads exceeding the output capacity
- Verify signal terminals and reference points according to Wiring Diagram
- Check power supply voltage and electrical protection systems
- Separate analog signal wires from power cables as appropriate to reduce interference
- Follow manufacturer's manual for shield and ground usage
- Confirm scaling settings and output status when the system starts up
- Avoid using general-purpose analog outputs instead of safety circuits requiring specific certification
- Do not insert or remove modules while powered, unless specified by the manufacturer
- Test all 4 output channels before putting the system into actual use
Important Notes Before Purchase
- The product is SANGI ELECTRIC Analog Output Module model PLC EXPLX3V-4DA
- Suitable for 4 analog outputs
- Supports voltage signal from -10 V to +10 V
- Supports current signal of 4-20 mA
- Has a 12-bit output resolution
- Achieves accuracy of ±1% as per catalog data
- Operates with power supply voltage at 24 VDC ±10%, operating current 55 mA
- Data speed of 15 ms/channel and 6 ms/channel must be confirmed from Datasheet
- This is not the Analog Input Module model EXPLX3V-4AD
- Check compatibility with PLC and accessories before purchasing