PLC EXPLX3V-4AD Analog Input Module SANGI ELECTRIC

Price on request – please contact us
Out of stock
SKU
051046
Out of stock

The price for this item is not shown online yet.

Ask for a price on LINE

SANGI ELECTRIC SCMA

PLC EXPLX3V-4AD, SANGI ELECTRIC Analog Input Module, PLC Analog Input Module, Analog Input Expansion Module, 4 Channel Analog Input, 4 Analog Inputs, 4 Point Analog Input, Industrial PLC Expansion Module, Voltage Input Module, Current Input Module, -10V to +10V Analog Input, Bipolar Voltage Input, 4-20mA Analog Input, Industrial Current Loop Input, 12 Bit Analog Input, 12 Bit Resolution, Analog Input Accuracy ±1%, Normal Speed 15ms/ch, High Speed 6ms/ch, 24VDC Analog Module, 24VDC ±10%, Module Current 55mA, Analog Signal Acquisition, PLC I/O Expansion, Industrial Automation Module, Process Measurement, Industrial Sensor Interface, Pressure Transmitter Input, Temperature Transmitter Input, Flow Transmitter Input, Programmable Logic Controller Expansion, EXPLX3V PLC Series, Factory Automation, Industrial Control System, SANGI ELECTRIC PLC, Analog Input Module, Analog Signal Acquisition Module, PLC Expansion Module, 4 Channel Analog Input Module, 4 Point Analog Input, Voltage Input Module, Current Input Module, -10 to +10V Analog Input Module, 4-20mA Analog Input Module, 12 Bit Analog Input Module, EXPLX3V-4AD PLC Module, Sensor Signal Acquisition Module, Industrial Measurement Signal Module, Machine Control Module, SANGI ELECTRIC PLC Device, Automation Control Device, Industrial PLC System, SANGI ELECTRIC EXPLX3V-4AD Thailand

*Price does not include VAT

SANGI ELECTRIC PLC EXPLX3V-4AD (Analog Input Module)

SANGI ELECTRIC PLC EXPLX3V-4AD is an analog input expansion module for PLC control systems, supporting 4 channels of analog input signals. It can accept standard voltage signals ranging from -10 V to +10 V and current signals in the range of 4-20 mA.

The module is suitable for connecting measuring and signaling devices in industrial systems such as Pressure Transmitter, Flow Transmitter, and Temperature Transmitter that have outputs matching the supported signal ranges. This allows data to be fed into the PLC system for processing, monitoring, and controlling machinery.

The device has a 12-bit resolution for signal conversion and supports an input response time of 15 ms/channel in Normal Speed mode and 6 ms/channel in High Speed mode as per the catalog specifications. The accuracy is ±1% for both types of signals according to the catalog.

The module operates on a power supply voltage of 24 VDC ±10%, with a current consumption of 55 mA, as specified in the catalog. It is suitable for expanding the analog input channels of compatible PLC systems.

Features

  • Brand: SANGI ELECTRIC
  • Model: PLC EXPLX3V-4AD
  • Type: Analog Input Module
  • Analog Inputs Supported: 4 Channels
  • Voltage Signal Range: -10 V to +10 V
  • Current Signal Range: 4-20 mA
  • Signal Reading Resolution: 12 bit
  • Normal Speed Mode Response Time: 15 ms/channel
  • High Speed Mode Response Time: 6 ms/channel
  • Absolute Accuracy ±1% as per catalog
  • Module Power Supply Voltage: 24 VDC ±10%
  • Module Current Consumption: 55 mA
  • Suitable for signals from Transmitters and industrial measuring devices
  • Used to expand Analog Input for compatible PLC systems

Technical Specifications

Specifications Details
BrandSANGI ELECTRIC
ModelPLC EXPLX3V-4AD
Product TypeAnalog Input Module
Number of Analog Inputs4 Channels
Voltage Input Range-10 V to +10 V
Current Input Range4-20 mA
Normal Speed15 ms/channel High Speed6 ms/channel Input Resolution12 bit Accuracy - Voltage Input±1% (-10 V to +10 V) Accuracy - Current Input±1% (4-20 mA) Module Supply Voltage24 VDC ±10% Module Current Consumption55 mA Input ImpedanceNot Specified in Catalog Electrical IsolationNot Specified in Catalog DimensionsNot Specified in Catalog Operating TemperatureNot Specified in Catalog Compatible PLC ModelsTo Be Confirmed from Manufacturer Documentation Catalog ReferenceSCMA General Catalog Vol.5, D3-05

Note: The catalog confirms the number of input channels, signal range for voltage and current, resolution, response time, accuracy, and module power supply information, but does not specify Input Impedance, isolation details, dimensions, or supported PLC models completely. Therefore, it is recommended to check the specific model datasheet before system design.

4 Analog Inputs

The SCMA EXPLX3V-4AD supports 4 analog signal inputs for connecting with measuring and signaling devices that have outputs compatible with standard signal ranges supported by the module.

This can be applied to receive data from multiple measurement points in a production process, but each channel configuration must be checked according to the manufacturer's manual.

Supports Voltage Signal -10 V to +10 V

The module supports analog voltage signals within the range of -10 V to +10 V as per catalog information. It is suitable for connecting devices that send bipolar voltage signals.

Before use, it is necessary to check signal terminals, reference voltages, and maximum acceptable voltage levels from the manufacturer's wiring diagram.

Supports Current Signal 4-20 mA

EXPLX3V-4AD supports the standard analog current signal of 4-20 mA, commonly used in industrial process measurement and control systems.

It can be applied to devices with a 4-20 mA output such as Pressure Transmitter, Flow Transmitter or Temperature Transmitter that are electrically compatible.

The selection must check whether the source device is Active or Passive type, as well as the power supply configuration of the Current Loop before connecting to the module.

Normal Speed and High Speed Modes

Operating Mode Response Time
Normal Speed15 ms/channel
High Speed6 ms/channel

The module has two response time modes for input consideration as per the catalog data, which can be selected based on signal characteristics and measurement process capabilities of the system.

Further details about mode configuration and impact on accuracy or signal filtering should be reviewed from the manufacturer's manual.

12-bit Resolution

The EXPLX3V-4AD has a 12-bit resolution for analog signal conversion, used to convert signals from external devices into digital values for processing in PLC systems.

A 12-bit resolution does not imply measurement accuracy as actual accuracy still depends on the circuitry of the signal converter, installation conditions and characteristics of connected measuring equipment.

Accuracy ±1%

The catalog specifies an accuracy of ±1% for signals ranging from -10 V to +10 V voltage and 4-20 mA current.

Detailed calculation basis and testing conditions for accuracy must be reviewed from the Datasheet before use in applications with specific precision requirements.

Power Supply 24 VDC ±10%

The module uses a power supply of 24 VDC ±10% and specifies an operating current of 55 mA for control cabinet power system design.

Sufficient power allowance should be considered for other devices in the system, along with checking the power supply configuration and circuit protection requirements as per the manufacturer's manual.

Usage with PLC Systems

The EXPLX3V-4AD is an Analog Input module to expand the number of signal channels supported by PLC systems. Before installation, compatibility must be checked for the main CPU model, maximum connected modules and channel configuration methods.

The name EXPLX3V Series should not be used to confirm compatibility with all CPU models without a manual.

Applications

  • Pressure Transmitter Signal Reception System
  • Flow Transmitter Signal Reception System
  • Temperature Transmitter Signal Reception System
  • -10 V to +10 V Voltage Signal Measurement System
  • 4-20 mA Current Signal Measurement System
  • Monitoring and Process Control Systems
  • Analog Input Expansion for PLCs
  • Factory Automation and Machine Control Systems
  • Control and Monitoring System Development in Industries

Selecting the EXPLX3V-4AD PLC

  • Check the number of Analog Input channels needed
  • Verify the type of signal from the source device
  • Confirm the signal range -10 V to +10 V or 4-20 mA
  • Consider response time 15 ms/channel or 6 ms/channel
  • Evaluate 12 bit resolution suitable for use
  • Check accuracy condition ±1%
  • Determine Active or Passive current circuit configuration
  • Verify power supply 24 VDC ±10%
  • Confirm compatibility with the main PLC
  • Review Wiring Diagram and signal channel setting procedures

Installation Precautions

  • Check Voltage or Current signal mode before wiring
  • Avoid exceeding Analog Input channel limits
  • Verify signal terminals and reference points according to the Wiring Diagram
  • Use power supply with appropriate ratings for the module
  • Follow manufacturer's specifications for Shield and Ground wiring
  • Separate analog signals from noisy power lines as necessary
  • Check signal range and Scaling settings in PLC program
  • Avoid inserting or removing modules while powered unless specified by the manual
  • Test all 4 channels before putting the system into actual use

Important Notes Before Purchase

  • The product is a SANGI ELECTRIC Analog Input Module model PLC EXPLX3V-4AD
  • Suitable for up to 4 Analog Input channels
  • Supports -10 V to +10 V voltage signals
  • Supports 4-20 mA current signals
  • Has response time of 15 ms/channel and 6 ms/channel depending on mode
  • Offers 12 bit resolution
  • Catalog specifies accuracy ±1%
  • Operates on 24 VDC ±10% power supply, current 55 mA
  • This is not the Analog Output Module model EXPLX3V-4DA
  • Must check compatibility with PLC and accessories before ordering
  • More Information
    Delivery Days3 days
    Write Your Own Review
    You're reviewing:PLC EXPLX3V-4AD Analog Input Module SANGI ELECTRIC
    Cookie settings
    🤖 AI Assistant
    Ask about products, specs and replacement models
    Hello 👋 Ask us anything — find products, compare specs, or troubleshoot.
    🗑 Clear history