SANGI FS06(1/4")-N-2-AC220V 5/2 Way Single Coil Pneumatic Solenoid Valve, 1/4" Size
SANGI FS06(1/4")-N-2-AC220V Pneumatic Solenoid Valve is a solenoid valve designed to control the direction of compressed air flow in pneumatic systems. It operates on a 5/2 Way or 5 Ports 2 Positions configuration, featuring five air ports and two operating positions.
This model has an air port size of 1/4 inch, uses a single coil (Single Coil) with AC220V power supply to change the valve position via electrical signals. It is suitable for controlling pneumatic equipment and air cylinders in automatic machinery systems.
General Features
- Product Model: FS06(1/4")-N-2-AC220V
- Brand: SANGI
- Product Type: Pneumatic Solenoid Valve
- Product Series: FS06
- Valve Configuration: 5/2 Way (5 Ports, 2 Positions)
- Air Port Size: 1/4 inch
- Operating Medium: Air (compressed air)
- Coil Type: Single Coil
- Coil Voltage: AC220V
- Controls and switches the direction of compressed air in pneumatic systems
- Suitable for automatic machine control and production processes
Technical Specifications (Technical Specifications)
| Model | FS06(1/4")-N-2-AC220V |
| Brand | SANGI |
| Product Series | FS06 |
| Product Type | Pneumatic Solenoid Valve |
| Valve Function | 5/2 Way |
| Number of Ports | 5 |
| Number of Positions | 2 |
| Port Size | 1/4" |
| Operating Medium | Air |
| Coil Configuration | Single Coil |
| Coil Voltage | 220VAC |
| Operating Pressure Range | 1.5-8 bar (FS Series Catalog) |
| Seal Material | NBR (Standard) |
| Ambient Temperature | -5 to +50°C |
| Body Material | Aluminium |
Operating Principle
The 5/2 Way Solenoid Valve has a total of five air channels, consisting of one supply channel, two working channels, and two exhaust channels. It can switch the direction of compressed air flow between the two operating positions to control the movement of pneumatic equipment such as double-acting cylinders.
For model FS06(1/4")-N-2-AC220V, when AC220V power is supplied to the coil, an electromagnetic field causes the valve mechanism to change position and switch air direction. A standard single-coil valve typically returns to its normal position once power is cut off. It is important to check the circuit symbols on the valve to confirm the operating principle and default position of the actual model in use.
Size and Installation
The FS06(1/4")-N-2-AC220V is a solenoid valve for compressed air systems, with an air port size of 1/4 inch. Before installation, it is necessary to verify that the thread standards and fitting sizes are compatible with the pneumatic tubing system.
Ensure that the supply, working, and exhaust ports are connected according to the symbols on the valve body, while also checking that the operating air pressure and compressed air quality meet the manufacturer's specifications.
The wiring should use an AC220V power source and control devices that support the coil’s voltage and current requirements. Before powering up, verify the frequency of the electrical supply, terminal connections, and plug configurations from the actual equipment.
Examples and Usage Guidelines
- Control the operation of double-acting pneumatic cylinders (Double-acting Cylinder)
- Switch the direction of compressed air flow in automatic machinery
- Apply to workpiece holding and moving systems using compressed air
- Connect to PLC through relays or switches that support AC220V coil control
- Use in production lines and industrial automation control systems
Considerations
- The FS06(1/4")-N-2-AC220V model is a single-coil 5/2 Way valve for compressed air.
- Use AC220V coil voltage; do not substitute with DC24V or AC110V directly.
- Verify that the operating air pressure falls within the range of 1.5-8 bar as per the FS Series catalog.
- Check the size and thread standards of ports before installation.
- Examine port connections and valve return position characteristics from symbols on the equipment.
- Confirm electrical frequency, coil power requirements, and plug configurations from product labels.
- Note that this model does not have an LED status indicator set as it lacks the -D- code designation.
Disconnect the power supply and release air pressure before installation or maintenance.