SANGI FD15(1/2")-N-2-AC110V 5/2 Way Double Coil Pneumatic Solenoid Valve with 1/2" Port Size
SANGI FD15(1/2")-N-2-AC110V Pneumatic Solenoid Valve is a solenoid valve designed to control the direction of compressed air flow in pneumatic systems. It features a 5/2 Way or 5 Ports, 2 Positions configuration with five air channels and two operational positions.
This model specifies an air port size of 1/2 inch according to its model code. It uses a double coil (Double Coil) with AC110V power supply for electrically actuating the valve position from both sides of the coils. Suitable for controlling pneumatic cylinders, automatic machinery, and industrial production systems that use compressed air.
General Features
- Model: FD15(1/2")-N-2-AC110V
- Brand: SANGI
- Product Type: Pneumatic Solenoid Valve
- Product Series: FD15
- Valve Configuration: 5/2 Way (5 Ports, 2 Positions)
- Air Port Size According to Model Code: 1/2 inch
- Operating Medium: Air (compressed air)
- Coil Type: Double Coil
- Coil Voltage: AC110V
- Controls and switches the direction of compressed air flow in pneumatic systems.
- Suitable for controlling pneumatic cylinders and automatic machinery.
Technical Specifications (Technical Specifications)
| Model | FD15(1/2")-N-2-AC110V |
| Brand | SANGI |
| Product Series | FD15 |
| Product Type | Pneumatic Solenoid Valve |
| Valve Function | 5/2 Way |
| Number of Ports | 5 |
| Number of Positions | 2 |
| Port Size | 1/2" (according to model code, please confirm actual port size) |
| Operating Medium | Air |
| Coil Configuration | Double Coil |
| Coil Voltage | 110VAC |
| Operating Pressure Range | 1.5-8 bar (FD Series Catalog) |
| Seal Material | NBR (Standard, FD Series) |
| Ambient Temperature | -5 to +50°C (FD Series Catalog) |
| Body Material | Aluminium (FD Series Catalog) |
Operating Principle
The 5/2 Way Solenoid Valve has a total of five air channels, consisting of one supply channel, two working channels, and two exhaust channels. It switches the direction of compressed air flow between the two operating positions to control the movement of pneumatic equipment such as double-acting cylinders.
For model FD15(1/2")-N-2-AC110V, it uses a dual coil system (Double Coil). The position change of the valve can be controlled by supplying AC110V power to either coil, and switching to another position through the other coil.
Generally, a 5/2 Way Solenoid Valve with a Double Coil can maintain its last position after power is cut off. However, it's important to check the circuit symbols and specific model specifications from the manufacturer to confirm the operating characteristics before designing the control system.
Size and Installation
The FD15(1/2")-N-2-AC110V specifies a 1/2 inch air pipe connection according to the model code. Before installation, it's necessary to verify that the actual port size and thread standard match those of the system air pipes since the product item detail mentions PIPE 1/4 which does not align with the model code.
Connect the supply channel, working channels, and exhaust channels as indicated on the valve symbol. Ensure that the pressure and quality of compressed air are suitable for use.
The electrical installation requires an AC110V power source and a control circuit capable of supporting both coils. Before powering up, check the frequency, coil wattage, terminals, and plug type from the actual equipment.
Examples and Usage Guidelines
- Control the operation of double-acting pneumatic cylinders (Double-acting Cylinder)
- Switch the direction of compressed air flow in automatic machinery
- Apply to workpiece holding and moving systems using compressed air
- Use with PLC through relays or switches that support both AC110V coils
- Used in pneumatic systems requiring valve position changes via dual coil power supply
Considerations
- The FD15(1/2")-N-2-AC110V model is a 5/2 Way Solenoid Valve with a Double Coil for compressed air.
- Use AC110V coil voltage; do not directly substitute AC220V or DC24V.
- Must confirm the actual port size before installation as the model code specifies 1/2 inch, but the product details specify PIPE 1/4
- Check the air pressure to ensure it meets the manufacturer's specifications
- Verify the thread standard and port position on the valve body before installation
- Inspect the electrical power, frequency, and wiring of both coil sets
- The control circuit should be designed to avoid energizing both coil sets simultaneously unless the manufacturer specifies that it is permissible
- Check the valve's hold position characteristics from the circuit symbols and the manufacturer’s manual
- No confirmed information exists regarding whether this model has an LED status indicator, so this feature is not specified
- Cut off power supply and exhaust air pressure before installation or maintenance