SANGI FD10(3/8")-N-2-AC220V 5/2 Way Double Coil Pneumatic Solenoid Valve with 3/8" Port Size
SANGI FD10(3/8")-N-2-AC220V Pneumatic Solenoid Valve is a solenoid valve designed to control the direction of compressed air flow in pneumatic systems. It operates on a 5/2 Way or 5 Ports 2 Positions configuration, featuring five air ports and two operational positions.
This model specifies an air port size of 3/8 inch as per its model code, uses double coil (Double Coil) with AC220V power supply to switch the valve position via electrical signals from both sides of the coil. It is suitable for pneumatic cylinder control systems, automatic machinery, and compressed air workpiece management systems in industrial applications.
General Features
- Model: FD10(3/8")-N-2-AC220V
- Brand: SANGI
- Type of Product: Pneumatic Solenoid Valve
- Product Series: FD10
- Valve Configuration: 5/2 Way (5 Ports, 2 Positions)
- Air Port Size as per Model Code: 3/8 inch
- Operating Medium: Air (compressed air)
- Coil Type: Double Coil
- Coil Voltage: AC220V
- Used for controlling and switching the direction of compressed air flow
- Suitable for automatic machinery and pneumatic cylinder control systems
Technical Specifications (Technical Specifications)
| Model | FD10(3/8")-N-2-AC220V |
| Brand | SANGI |
| Product Series | FD10 |
| Product Type | Pneumatic Solenoid Valve |
| Valve Function | 5/2 Way |
| Number of Ports | 5 |
| Number of Positions | 2 |
| Port Size | 3/8" (as per model code, actual size to be confirmed) |
| Operating Medium | Air |
| Coil Configuration | Double Coil |
| Coil Voltage | 220VAC |
| Operating Pressure Range | 1.5-8 bar (FD Series Catalog) |
| Seal Material | NBR (Standard, FD Series) |
| Ambient Temperature | -5 to +50°C (FD Series Catalog) |
| Body Material | Aluminium (FD Series Catalog) |
Operating Principle
The 5/2 Way Solenoid Valve has a total of five air channels, consisting of one supply channel, two working channels, and two exhaust channels. It switches the direction of compressed air flow between the two operating positions to control pneumatic equipment such as double-acting cylinders.
For model FD10(3/8")-N-2-AC220V, it uses a dual coil system (Double Coil). The position change of the valve can be controlled by supplying AC220V power to either side of the coils.
A 5/2 Double Coil Valve typically retains its last position after power is cut off. However, the circuit symbols and manufacturer specifications should be checked to confirm the operating characteristics before designing a control system.
Size and Installation
The FD10(3/8")-N-2-AC220V model specifies an air port size of 3/8 inch according to the model code. Before installation, verify the actual port size, thread standard, and fitting size to match the pneumatic system since the product description mentions PIPE 1/4 inch which does not align with the model code.
Connect the supply channel, working channels, and exhaust channel as indicated on the valve symbol. Also, check that the air pressure and compressed air condition meet the manufacturer's specifications.
For electrical systems, AC220V power source and control circuits supporting dual coils must be used. Verify the frequency of electricity, coil power consumption, and wiring details from the equipment label or manufacturer documentation before powering up.
Examples and Usage Guidelines
- Control double-acting pneumatic cylinders (Double-acting Cylinder)
- Switch the direction of compressed air flow in automatic machinery
- Use in systems for holding and moving workpieces with compressed air
- Work together with PLC through relays or switches that support both AC220V coils
- Used in pneumatic systems requiring position changes controlled by separate dual coils
Considerations
- The FD10(3/8")-N-2-AC220V model is a 5/2 Way Solenoid Valve with a double coil system for compressed air.
- It uses AC220V coils, direct replacement with DC24V or AC110V power supply should not be done.
- The actual port size must be confirmed before installation as the model code specifies 3/8 inch but the product description mentions PIPE 1/4 inch.
Check the operating air pressure range as per the manufacturer's specifications
Verify the size and thread standard before selecting the fitting
Check the electrical frequency, power rating, and coil wiring diagram for both sets of coils
The control circuit should be designed so that both sets of coils do not receive commands simultaneously unless the manufacturer specifies otherwise
Confirm the valve's position holding characteristics from the actual circuit symbol
No confirmed information is available to indicate this model has an LED status indicator, hence this feature is not specified
Cut off power and exhaust air pressure before installation or maintenance