SANGI FD06(1/4")-N-2-D-DC24V 5/2 Way Pneumatic Solenoid Valve with Double Coil, 1/4" Size
SANGI FD06(1/4")-N-2-D-DC24V Pneumatic Solenoid Valve is a solenoid valve designed to control the direction of compressed air flow in pneumatic systems. It operates on a 5/2 Way or 5 Ports, 2 Positions configuration, featuring five total air ports and two operational positions.
This model features an air connection port size of 1/4 inch with a double coil (Double Coil) at DC24V voltage for electrically controlling the valve position through signals from both coils. It is suitable for automated machinery requiring compressed air direction control, such as pneumatic cylinder drive systems.
General Features
- Product Model: FD06(1/4")-N-2-D-DC24V
- Brand: SANGI
- Product Type: Pneumatic Solenoid Valve
- Product Series: FD06
- Valve Configuration: 5/2 Way (5 Ports, 2 Positions)
- Air Connection Port Size: 1/4 inch
- Operating Medium: Air (compressed air)
- Coil Type: Double Coil
- Coil Voltage: DC24V
- Used for controlling and switching the direction of compressed air flow
- Suitable for automated machinery and pneumatic control systems
Technical Specifications (Technical Specifications)
| Model | FD06(1/4")-N-2-D-DC24V |
| Brand | SANGI |
| Product Series | FD06 |
| Product Type | Pneumatic Solenoid Valve |
| Valve Function | 5/2 Way |
| Number of Ports | 5 |
| Number of Positions | 2 |
| Port Size | 1/4" |
| Operating Medium | Air |
| Coil Configuration | Double Coil |
| Coil Voltage | 24VDC |
| Operating Pressure Range | 1.5-8 bar (FD Series Catalog) |
| Seal Material | NBR (Standard) |
| Ambient Temperature | -5 to +50°C |
| Body Material | Aluminium |
Operating Principle
The 5/2 Way Solenoid Valve has a total of five air channels, including one supply channel, two working channels, and two exhaust channels. It can switch the direction of compressed air flow between the two operating positions to control pneumatic equipment such as double-acting cylinders.
For model FD06(1/4")-N-2-D-DC24V, it uses a dual coil setup. When DC24V power is supplied to one coil, the valve switches to the position associated with that coil and can switch to another position through the other coil.
Generally, a 5/2 Way Solenoid Valve with a dual coil setup can maintain its last position after power-off, but it's advisable to check the operating characteristics and specifications of this model from circuit symbols or manufacturer’s manual before actual use.
Size and Installation
The FD06(1/4")-N-2-D-DC24V is a solenoid valve for compressed air systems with 1/4 inch pipe connections. Before installation, ensure that the thread standards and connection sizes are appropriate for your pneumatic system.
Connect the supply channel, working channels, and exhaust channels according to the symbols on the valve body, and verify the wiring of both coils correctly using a 24VDC power source and control circuits compatible with coil power requirements.
Examples and Usage Guidelines
- Control double-acting pneumatic cylinders (Double-acting Cylinder)
- Switch the direction of compressed air flow in automatic machinery
- Apply in systems for gripping and moving workpieces using compressed air
- Use with PLCs that have two DC24V coil drive circuits as appropriate
- Apply in pneumatic systems requiring valve position changes from dual coils
Considerations
- The FD06(1/4")-N-2-D-DC24V is a 5/2 Way Solenoid Valve with a dual coil setup for compressed air.
- Use 24VDC coil voltage; do not supply AC110V or AC220V to the coils.
- Check the operating air pressure range according to manufacturer specifications.
- Verify the size and thread standards of the 1/4 inch port before installation.
- Inspect the power requirements and wiring details for both coil sets.
- Avoid simultaneously powering both coil sets unless specified by the manufacturer as permissible.
- Check accessory codes -D- and plug set details from specific model documentation.
Check the valve positioning characteristics from the circuit symbols
Disconnect power supply and exhaust air pressure before installation or maintenance