MDA-U2, SUPMEA, universal controller, water quality controller, water quality measuring and controlling device, wall-mounted water quality controller, pH control unit, ORP control unit, EC control unit, dissolved oxygen meter, turbidity meter, suspended solids concentration meter, RS-485 Modbus RTU water quality controller
Details of MDA-U2 SUPMEA Universal Water Quality Meter and Controller
The MDA-U2 SUPMEA is a panel-mounted water quality meter and controller that supports parameters such as pH, ORP, conductivity (EC), dissolved oxygen (DO), turbidity, and total suspended solids. The working parameter depends on the sensor or electrode connected. It features a 2.8-inch black-and-white LCD screen with a resolution of 128 × 64 pixels, along with a 4–20mA current output, RS-485 Modbus RTU isolated communication, and two relay outputs for connecting to water quality monitoring and control systems.
Features of MDA-U2 SUPMEA
Suitable for measuring pH, ORP, EC, DO, turbidity, and total suspended solids based on the selected sensor type
A 2.8-inch black-and-white LCD screen with a resolution of 128 × 64 pixels
4–20mA current output to send measurement values to control or display systems
RS-485 Modbus RTU isolated communication
Two relay outputs supporting loads up to 3A/250VAC
An output power supply of 12V/125mA
Operates on a power source of 100–240VAC and has an option for a 24VDC power supply
Panel mountable with a mounting hole size of 92.5 × 92.5 millimeters
Measurement Range of MDA-U2 SUPMEA
pH: 0–14 pH
ORP: -2000 to +2000 mV
Dissolved Oxygen (DO): 0–40 mg/L
Oxygen Saturation: 0–200%
Conductivity (EC): 0–600 mS/cm
Turbidity: 0–4000 NTU
Total Suspended Solids: 0–120,000 mg/L
The actual measurement range used depends on the connected sensor or electrode
Technical Data of MDA-U2 SUPMEA
Display: 2.8-inch black-and-white LCD screen
Screen resolution: 128 × 64 pixels
Current output: 4–20mA
Maximum load of current output: 500Ω
Accuracy of current output: ±0.2% F.S.
Communication: RS-485 Modbus RTU isolated communication
Relay outputs: Two channels
Contact rating for relays: 3A/250VAC
Output power supply: 12V/125mA
Operating temperature: 0–60°C
Relative humidity during operation: 10–85% RH without condensation
Storage temperature: -15 to 65°C
Relative humidity for storage: 5–95% RH without condensation
Operating altitude level: Below 2,000 meters
Power Supply: 100–240VAC
Power Supply Option: 24VDC
Size and Installation of MDA-U2 SUPMEA
Unit Size: 100 × 100 × 150 millimeters
Pan Panel Cutout Size: 92.5 × 92.5 millimeters
Mounting Style: Panel Mount
Usage Guidelines for MDA-U2 SUPMEA
Monitor water quality during production by selecting sensors that match the desired parameters.
Measure pH, ORP or EC in water treatment systems.
Monitor DO, turbidity or other parameters with compatible sensors.
Transmit measurement values via 4–20mA or RS-485 Modbus RTU to control systems.
Use relay outputs with appropriate alarm or control circuits.
Considerations Before Use
Check sensor type, interface and configuration compatibility with the controller.
Multiparameter support does not mean simultaneous measurement of all parameters; check input format and sub-model before ordering.
The 24VDC power supply option must be specified for the ordered model.
Operate within specified temperature and humidity ranges, avoiding condensation.