KEPLER KUV-218C UVC Light Meter (UVC Light Meter)
KEPLER KUV-218C UVC Light Meter is a UV-C (Ultraviolet-C) light intensity meter designed for checking the intensity levels of UV-C lamps or ultraviolet radiation sources within the supported wavelength range. It is suitable for tasks such as inspecting UV-C lamps, maintaining UV lighting systems, and measuring industrial processes.
The device supports measurement of UVC radiation in the 220-280 nm wavelength range with a maximum measurable intensity of 9,999 µW/cm² in the µW/cm² range and up to 40 mW/cm² in the mW/cm² range. It offers a resolution of 1 µW/cm² or 0.01 mW/cm² depending on the selected measurement range.
The KUV-218C has an accuracy of ±(4% + 1 digit) according to the catalog data and supports temperature measurements in the range of 0-70°C with a resolution of 0.1°C, allowing for accurate monitoring of radiation intensity and temperature during testing.
The device comes equipped with a backlit LCD display featuring MAX, MIN, Average Hold, and Data Hold functions, along with memory capable of storing up to 200 data points. This makes it ideal for measuring radiation intensity at various locations and comparing measurement results during use.
General Features
- Brand: KEPLER
- Model: KUV-218C
- Type of Product: UVC Light Meter
- Used for measuring UV-C radiation intensity
- Suitable wavelength range 220-280 nm
- Maximum measurable radiation intensity up to 9,999 µW/cm² and 40 mW/cm²
- Measurement resolution of 1 µW/cm² or 0.01 mW/cm² depending on the measurement range
- Radiation measurement accuracy ±(4% + 1 digit)
- Suitable for temperature measurements in the range of 0-70°C
- Temperature measurement resolution of 0.1°C
- LCD display with backlight
- Supports displaying maximum, minimum, and average values
- Data Hold function to maintain displayed values on screen
- Memory capable of storing up to 200 data points
- Suitable for inspecting UV-C lamps and measuring radiation in industrial processes
Technical Specifications (Technical Specifications)
| Brand | KEPLER |
| Model | KUV-218C |
| Product Type | UVC Light Meter |
| Measurement Parameter | UVC Irradiance / Temperature |
| Spectral Range | 220-280 nm |
| UVC Measuring Range 1 | 0-9,999 µW/cm² |
| UVC Measuring Range 2 | Up to 40 mW/cm² |
| UVC Resolution 1 | 1 µW/cm² |
| UVC Resolution 2 | 0.01 mW/cm² |
| UVC Accuracy | ±(4% + 1 digit) |
| Temperature Range | 0-70°C |
| Temperature Resolution | 0.1°C |
| Display | LCD with Backlight |
| Display Count | 9,999 Counts |
| Data Memory | 200 Records |
| Measurement Functions | MAX / MIN / Average Hold / Data Hold |
| Calibration Wavelength | Refer to Model-Specific Calibration Documentation |
| Power Supply | Refer to Manufacturer Datasheet |
| Dimensions | Refer to Manufacturer Datasheet |
| Weight | Refer to Manufacturer Datasheet |
UVC Light Meter Operation Principle
The UVC light meter uses a sensor head that responds to ultraviolet radiation within the specified wavelength range. When UV radiation strikes the sensor head, the device converts the detected signal into irradiance values for display on the screen.
The UVC irradiance value is displayed in units of µW/cm² or mW/cm², which are units of radiant power per unit area. Proper positioning of the measuring head and distance from the radiation source must be ensured during measurement to allow accurate comparison between measurements.
The KUV-218C supports a wavelength range of 220-280 nm, making it suitable for checking UVC radiation sources with spectra within this range. The sensitivity of the measuring head may vary depending on the wavelength, and calibration data should be reviewed when high accuracy is required.
Measurement Functions
- UVC Irradiance: Measures UVC irradiance in units of µW/cm² and mW/cm²
- Temperature Measurement: Measures temperature in the range of 0-70°C
- MAX Hold: Displays or retains the highest radiation intensity value measured
- MIN Hold: Displays or retains the lowest radiation intensity value measured
- Average Hold: Displays or retains the average of data according to the instrument function
- Data Hold: Keeps current measurement values on the display screen
- Data Memory: Records up to 200 measurement values
- LCD Backlight: Helps read measurements easily in low-light areas
Usage and Measurement
- Check the readiness of the instrument and sensor head before use
- Ensure that the wavelength of the radiation source is within 220-280 nm range
- Select an appropriate measurement range for expected radiation intensity levels
- Set distance and position of the measuring head according to the purpose of measurement
- Avoid blocking radiation from reaching the sensor head
- Measure inside a suitable shielding system without direct exposure to operators
- Wait until the measured value stabilizes before reading or recording results
- Use MAX / MIN / Average Hold functions when comparing measurement results
- Record measurement values in the instrument's memory as appropriate
- Turn off and store the sensor head according to manufacturer instructions after use
Examples and Usage Guidelines
- Check UVC lamp radiation intensity
- Evaluate UVC light source degradation by comparing measurements under identical conditions
- Use for inspection and maintenance of UV lighting systems
- Apply in testing and monitoring industrial UVC irradiation systems
- Verify the consistency of radiation intensity at various test area positions
- Utilize for studying the efficiency of UVC light sources
- Apply in testing and quality control of systems using UV-C radiation
Considerations
- The KUV-218C model supports UVC radiation measurement within 220-280 nm range
- Avoid measuring UVA or UVB if the wavelength is outside the specified response range
- To compare results, use the same position and distance when checking UVC lamps
Measuring the intensity of UVC radiation does not directly confirm disinfection effectiveness, as effectiveness depends on accumulated dose, time, type of microorganism, and other conditions.
The calibration status and reference wavelength should be checked before using results in quality control work.
UVC radiation can harm eyes and skin; preventive measures must be taken and direct exposure avoided.
Check the accessories, power supply, and actual items shipped before purchasing.