KEPLER KH-100DL Pen Type Hardness Tester (Metal Hardness Testing Instrument)
KEPLER KH-100DL Pen Type Hardness Tester is a portable and compact metal hardness measuring and testing device that uses the Leeb Rebound Hardness Testing principle, equipped with an internal DL-type impact device. It is suitable for checking the hardness of metal parts, production quality control, and machinery inspection in industrial applications.
The DL-type impact head has a slender and elongated tip design, which allows it to be applied to restricted access measurement positions such as grooves, narrow areas, or regions where standard D-type heads are not convenient. The suitability of the workpiece shape and testing method must be verified before actual use.
It supports a measuring range of 170-960 HL according to the KH-100 Series model data table, with an automatic impact direction detection system for 360 degrees, and it can display or convert hardness units such as HL, HB, HRB, HRC, HRA, HV, and HS based on material type and supported conversion conditions.
The KH-100DL features a High-Contrast Segment LCD screen that supports Single-Point Calibration, stores up to 100 groups of data, and connects to a computer via USB 1.1 for use with compatible PC management software provided by the manufacturer.
General Features (Features)
- Brand: KEPLER
- Model: KH-100DL
- Type of Product: Pen Type Hardness Tester
- Portable metal hardness tester
- Bases on Leeb Rebound Hardness Testing principle
- Equipped with DL-type impact device (DL-Type Impact Device) internally
- The slender and elongated tip design is suitable for accessing certain measurement positions with limited space
- Measuring range: 170-960 HL according to model data table
- Suitable for multi-directional measurements of 360 degrees
- Automatic impact direction detection
- Supports hardness units such as HL, HB, HRB, HRC, HRA, HV and HS
- Supports Single-Point Calibration
- High-Contrast Segment LCD screen
- Data storage capacity up to 100 groups
- Average value calculation can be set from 1 to 32 times
- USB 1.1 computer connectivity support
- Supports use with PC Software
- Battery powered by a built-in Lithium Polymer battery of 3.7 V
The body is made of ABS Engineering Plastic
Suitable for hardness testing and quality control of metal parts
Technical Specifications
| Specifications | Details |
| Brand | KEPLER |
| Model | KH-100DL |
| Product Type | Pen Type Hardness Tester |
| Measuring Principle | Leeb Rebound Hardness Testing |
| Impact Device | DL Type Integrated |
| Measuring Range | 170-960 HL (Catalog Series Specification) |
| Impact Direction | 360 Degrees / Automatically Identified |
| Hardness Scales | HL, HB, HRB, HRC, HRA, HV, HS |
| Error and Repeatability | Not Separately Specified for DL-Type in Catalog |
| Minimum Hardened Layer Depth | Not Separately Specified for DL-Type in Catalog |
| Display | High-Contrast Segment LCD |
| Data Storage | Up to 100 Groups |
| Average Times Setting | 1-32 Measurements |
| Calibration | Single-Point Calibration |
| Data Printing | Connect PC to Print |
| PC Software | Supported |
| Communication Interface | USB 1.1 |
| Battery | Built-in Lithium Polymer Battery |
| Battery Voltage | 3.7 V |
| Standby Time | Approximately 200 Hours (Without Backlight, Catalog Rating) |
| Housing Material | ABS Engineering Plastic |
| Dimensions | 148 x 33 x 28 mm (Catalog Series Listing; Verify DL Configuration) |
| Weight | Approximately 80 g (Catalog Series Listing; Verify DL Configuration) |
Operation of Leeb Hardness Tester
The Leeb hardness tester operates on the principle of measuring the velocity of the impact head before contacting the workpiece and after rebounding from its surface. The system then calculates the hardness value in Leeb Hardness (HL) units based on this relationship.
The measurement results can be converted to other hardness units according to tables or equations supported by the device, depending on the material type and testing conditions.
Hardness values converted to HB, HRC, HV, or other units are comparative values derived from conversion systems. They should not be considered equivalent to direct tests performed with Brinell, Rockwell, or Vickers testers in all cases.
DL-Type Impact Device
The KH-100DL model is equipped with a DL-type impact device, which differs from the KH-100D and KH-100C models. The characteristic of the elongated pointed tip of the impact head allows for easier access to certain positions on workpieces that have limited space.
It can be applied to areas such as grooves or measurement points where standard impact heads cannot be properly positioned. However, actual measuring capability depends on the size and shape of the workpiece, support strength, contact position, and Leeb Hardness Testing system requirements.
The catalog does not specify a separate minimum case hardening depth value for DL-Type; therefore, it is necessary to check from the specific model manual before testing workpieces with thin case-hardened layers.
Hardness Scales
| Hardness Scale | Description |
| HL | Leeb Hardness |
| HB | Brinell Hardness |
| HRB | Rockwell Hardness B Scale |
| HRC | Rockwell Hardness C Scale |
| HRA | Rockwell Hardness A Scale |
| HV | Vickers Hardness |
| HS | Shore Hardness Scale according to supported conversion systems |
The selection of hardness units should consider the material type and the range supported by the device, as the relationship for converting values may differ between materials.
Supported Material Groups According to the Catalog
- Steel and Cast Steel — Carbon steel and cast carbon steel
- Cold Work Tool Steel — Cold work tool steel
- Stainless Steel — Stainless steel
- Grey Cast Iron — Grey cast iron
- Nodular Cast Iron — Nodular cast iron
- Cast Aluminum — Cast aluminum
Each material type must select appropriate material data and hardness units according to the functions supported by the machine, along with evaluating the suitability of the DL impact tip for the actual shape and size of the workpiece.
Data Recording System and Computer Connectivity
The device can record up to 100 groups of measurement results, supporting the setting of a number of measurements from 1-32 times as per catalog data for calculating average values.
It features a USB 1.1 port for connecting to a computer to transfer or manage data with PC software according to manufacturer capabilities.
Data printing through a computer is supported, though it does not specify an in-built printer.
Single-Point Calibration Method
The KH-100DL supports Single-Point Calibration and should use the appropriate standard hardness block for the DL impact tip and the workpiece's hardness range.
Users should check reference block values and calibration procedures according to the machine manual, as well as verify accuracy before starting actual measurements.
Examples and Usage Guidelines (Applications)
- Checking the hardness of steel and carbon steel parts
- Checking the hardness of stainless steel parts
- Checking the hardness of castings
- Checking the hardness of machine components
- Checking parts with grooves or limited access areas
- Checking the hardness of dies and tools
- Checking the hardness of automotive parts
- Used in quality control and metal workpiece inspection tasks
Preparation Guidelines and Measurement Procedures
- Check the condition of the machine and DL impact tip before use.
- Check battery and display screen conditions.
- Select appropriate material type and hardness units.
- Inspect workpiece thickness, weight, and stability.
- Clean and prepare surface according to Leeb measurement requirements.
- Use a standard hardness block suitable for the DL impact tip to check values before use.
Select the measurement position where the hammer head can properly contact the workpiece
Align the instrument according to the manufacturer's instructions
Repeat measurements as required and consider the average value
Record test results according to quality inspection plans
Clean the hammer head and store the machine after use
Standard Accessories According to Catalog (Included Accessories)
- KEPLER KH-100DL Hardness Tester
- Standard Hardness Test Block as per item set, must confirm suitability with DL hammer head
- DataPro Software
- USB Communication Cable
- Charger
- Nylon Brush
- Small Support Ring
- ABS Instrument Case
- Certificate
- Instruction Manual
Note on the Set of Accessories: The standard accessory table in the catalog is shared for KH-100D, KH-100C and KH-100DL specifying D-Type Standard Hardness Block. Therefore, it's important to confirm the type and standard value of the block shipped with KH-100DL before ordering.
Considerations Before Ordering
- KH-100DL uses DL-Type Integrated hammer head, not D-Type or C-Type
- The measurement range 170-960 HL is specified in the KH-100 Series model group table
- Error ±6 HLD value listed in the catalog applies to D-Type, not confirmed accuracy for DL-Type
- The catalog does not specify a separate minimum case hardening depth for DL-Type
- The long narrow tip hammer head design is not guaranteed to measure all narrow areas or grooves
- Thin, light-weight, or poorly supported workpieces may require special support methods
- Hardness unit conversion depends on material type and the range of the conversion table
- Appropriate hardness reference blocks for DL-Type should be used
- Check the actual set of accessories and reference block types shipped
- The OLED, Bluetooth features or 600 group memory of KH-270 and KH-278 should not be applied to KH-100DL