KEW 4105DLBT, KYORITSU, 3 Wire Digital Earth Tester, Digital Earth Resistance Tester, Earth Ground Tester, Ground Resistance Meter, 2 Wire 3 Wire Earth Tester, Bluetooth Earth Tester, IP67 Earth Resistance Tester, Digital Ground Resistance Tester, Earth Voltage Tester, Digital Earth Resistance Tester, Three-lead Earth Tester, Bluetooth-enabled Earth Tester, System Lead Testing Device, KYORITSU Digital Earth Resistance Tester

*Price does not include VAT

Digital Earth Tester with Bluetooth KYORITSU Model KEW 4105DLBT

KYORITSU KEW 4105DLBT 3 Wire Digital Earth Tester is a digital earth resistance tester for measuring and testing the grounding system's resistance values in electrical installation and maintenance work. It supports both two-pole and three-pole measurement methods, along with an earth voltage (Earth Voltage) measurement function.

The device features a large LCD screen with backlight, rotary switch selection functions, and LED status indicators for auxiliary ground connection. It includes built-in Bluetooth for data transfer and is rated IP67, making it suitable for indoor grounding system checks in buildings, industrial plants, and electrical installation work.

General Features

  • Brand: KYORITSU
  • Model: KEW 4105DLBT
  • Type of Product: Digital Earth Resistance Tester
  • Earth Resistance Measurement Method: Two-Pole and Three-Pole Measurement
  • Range of Earth Resistance Measurement: 20Ω / 200Ω / 2000Ω
  • Earth Voltage Measurement: AC/DC
  • Communication: Bluetooth
  • Display: LCD with Backlight
  • Function Selection: Rotary Switch
  • Status Indicators: LED for Auxiliary Ground Connection Status
  • Comparison Function: Comparator
  • Degree of Protection: IP67
  • Battery Type: 1.5V LR6 (AA) Batteries x 6
  • Dimensions: 121 x 188 x 59 mm (including case)
  • Weight: Approximately 690 g (including batteries and case)

Range of Earth Resistance Measurement (Earth Resistance)

Item 20Ω Range 200Ω Range 2000Ω Range
Display Range 0.00-20.99Ω 0.0-209.9Ω 0-2099Ω
Accuracy ±(1.5%rdg+0.08Ω) ±(1.5%rdg+4dgt) ±(1.5%rdg+4dgt)
Main Earth Bond Resistance <10kΩ <50kΩ <100kΩ
Comparator Reference Value 10Ω 100Ω 500Ω

Earth Voltage Measurement

  • AC Voltage Range: 0-300VAC (45-65Hz)
  • DC Voltage Range: ±0 to ±300VDC
  • Accuracy: ±(1%rdg+4dgt)

Overload Protection System

  • Earth Resistance Mode: 360VAC for 10 seconds
  • Earth Voltage Mode: 360VAC for 10 seconds

Bluetooth Functionality

The KEW 4105DLBT model comes with built-in Bluetooth capability, allowing data transfer of measurement results to compatible devices. This facilitates the storage and review of ground system test data.

Display and Usage Features

  • Large LCD screen with backlight
  • Rotary switch for selecting testing functions
  • LED status indicator for main earth bond connection suitability
  • Suitable for 2-pole and 3-pole ground resistance measurements
  • Included Comparator function with reference values according to measurement range

Safety Standards

  • IEC 61010-1
  • CAT IV 100V / CAT III 150V / CAT II 300V
  • Pollution Degree 3
  • IEC 61010-2-030
  • IEC 61010-031
  • IEC 61557-1, IEC 61557-5
  • IEC 60529 IP67
  • IEC 61326-1, IEC 61326-2-2
  • EN 50581 (RoHS)

Usage Examples and Guidelines

  • Check the earth resistance value in electrical systems
  • Inspect ground wiring systems of office buildings and industrial plants
  • Verify grounding of control panels and power distribution systems
  • Evaluate installed earth resistance after installation
  • Measure earth voltage before conducting resistance tests
  • Transfer test data via Bluetooth for record-keeping purposes

Limits and Considerations

  • Select the appropriate two-terminal or three-terminal measurement method for the system you want to check
  • Earth electrode measurements must be set up and carried out according to the manufacturer's manual
  • The earth electrode resistance must fall within the range of the selected measurement interval
  • The environmental conditions and soil voltage must be checked before starting the test
  • CAT IV 100V / CAT III 150V / CAT II 300V ratings must be used in accordance with the specified circuit type
  • IP67 rating must be used under the conditions of lid closure and protection as stated in the manual
  • The accessories and measurement cable set shipped with model KEW 4105DLBT should be checked before ordering
  • Note: The KEW 4105DLBT is the Bluetooth-equipped version, while the KEW 4105DLBT-H as per the SCMA General Catalog Vol.5 page B1-56 comes with a hard case (Hard Case).

Write Your Own Review
You're reviewing:KEW 4105DLBT 3 WIRE DIGITAL EARTH TESTERS KYORITSU
Cookie settings
🤖 AI Assistant
Ask about products, specs and replacement models
Hello 👋 Ask us anything — find products, compare specs, or troubleshoot.
🗑 Clear history