KCTM-24 V, 300A/333mV SPLIT CORE CURRENT TRANSFORMER KEPLER

Price on request – please contact us
Out of stock
SKU
050952
Out of stock

The price for this item is not shown online yet.

Ask for a price on LINE

KEPLER SCMA

KCTM-24 V, KEPLER, Split Core Current Transformer, KCTM-24V Series, 300A/333mV, 300A Current Transformer, 333mV AC Output, Split Core CT, Split Type Current Transformer, Voltage Output CT, AC Current Sensor, 50/60Hz Current Transformer, Class 0.5, Current Measurement, Electrical Monitoring, Energy Monitoring, Power Monitoring, Industrial Electrical Measurement, Electric Current Transformer, Separable Core Current Transformer, Split Core Current Transformer, CT with Voltage Output, Current Transformer 300A/333mV, AC Current Sensor, Electrical Measurement Device, Energy Metering Equipment, Power Monitoring Device, KEPLER Current Transformer

*Price does not include VAT

KEPLER KCTM-24 V Split Core Current Transformer

KEPLER KCTM-24 V Split Core Current Transformer is a detachable core (Split Core CT) current transformer designed for measuring alternating current in electrical systems. It has a primary rated current of 300A and an output of 333mV AC at the rated current, suitable for use with measurement devices or meters that support a 333mV AC CT input.

The device is designed to allow opening and closing of the transformer core, enabling installation around electrical conductors without needing to disconnect existing connections. However, installation must follow appropriate electrical safety procedures.

Model KCTM-24 V belongs to the KEPLER KCTM-24V Series with an output voltage of 333mV AC, differing from transformers that have a 5A output, thus requiring selection and use with compatible signal receiving equipment.

General Features

  • Brand: KEPLER
  • Model: KCTM-24 V
  • Type of Product: Split Core Current Transformer
  • Detachable core current transformer, can open the core for installation around conductors.
  • Rated primary current: 300A AC
  • Rated output voltage: 333mV AC
  • Precision: Class 0.5 as per series catalog data
  • Supports frequency range: 50-60Hz
  • Housing made of PC / UL94-V0 material
  • Suitable for current measurement and energy monitoring systems.

Technical Specifications (Technical Specifications)

BrandKEPLER
ModelKCTM-24 V
Product SeriesKCTM-24V Series
Product TypeSplit Core Current Transformer
Rated Primary Current300A AC
Rated Output333mV AC
Accuracy ClassClass 0.5 (Series Reference)
Frequency50-60Hz
Phase AngleLess than 2 degrees at 50% of rated current (Series Reference)
Insulation Voltage600VAC (Series Reference) Maximum Primary Voltage5000VAC, Insulated Conductor (Series Reference) Dielectric Strength2.5kV / 1mA / 1min (Series Reference) Operating Temperature-15 to +60°C Operating HumidityLess than 85% RH Case MaterialPC / UL94-V0 Bobbin MaterialPBT Core MaterialPermalloy Internal StructureEpoxy Lead WireUL1015, Twisted Pair, 22 AWG (Series Reference) Compatible Measurement Input333mV AC CT Input

How It Works

A split core current transformer operates based on the principle of electromagnetic induction. When alternating current flows through a conductor within the CT core, it generates a magnetic field that induces an electrical signal in the secondary winding.

The KCTM-24 V model with a rating of 300A/333mV is designed to have an output voltage rating of 333mV AC when there is a primary current of 300A AC. The output voltage changes proportionally to the measured current, under conditions specified by the manufacturer.

The 333mV AC output signal can be used with meters or measurement devices that have an input for CTs rated at 333mV. It is necessary to set the CT ratio to match 300A/333mV in order for the system to accurately display current.

Installation and Usage

  • Select the alternating conductor where you want to measure the current.
  • Cut off power supply and ensure there is no voltage before installation.
  • Open the split core and install it around a single wire of the circuit that needs to be measured.
  • Close the CT core completely according to the locking mechanism of the device.
  • Connect the signal wires to a meter that supports 333mV AC CT input.
  • Set the CT Ratio or CT Rating in the measuring device to match 300A/333mV.
  • Check the installation direction and polarity from the manufacturer's documentation.

Examples and Usage Guidelines

  • Measure electrical current in control panels and power distribution cabinets
  • Works with Energy Monitoring systems supporting 333mV CT input
  • Measures load currents of machinery and industrial electrical equipment
  • Adaptable for building energy consumption monitoring systems
  • Used with current measurement systems requiring open-CT installation

Considerations

  • This model is a 333mV AC output CT, not a 5A output CT
  • Meters or measuring devices supporting 333mV AC input must be used in conjunction
  • Check the current rating and measurement range to match actual usage requirements
  • Verify that the CT core size is appropriate for the wire or busbar size
  • For general load current measurements, wrap the CT around a single conductor only, not around phase and neutral wires together
  • Ensure proper CT Ratio settings and signal polarity before use
  • Some technical data references KCTM-24V Series; installation documentation should be reviewed for specific model details
  • Installation in electrical systems must be performed by qualified personnel following electrical safety measures