Toggle Nav
My Cart 0

KCTM-24 V, 200A/333mV SPLIT CORE CURRENT TRANSFORMER KEPLER

Price on request – please contact us
Out of stock
SKU
050950
Out of stock

The price for this item is not shown online yet.

Ask for a price on LINE

KEPLER SCMA

KCTM-24 V, KEPLER, Split Core Current Transformer, KCTM-24V Series, 200A/333mV, 200A Current Transformer, 333mV AC Output, Split Core CT, Split Type Current Transformer, Voltage Output CT, AC Current Sensor, 50/60Hz Current Transformer, Class 0.5, Current Measurement, Electrical Monitoring, Energy Monitoring, Power Monitoring, Industrial Electrical Measurement, Current Transformer, Split Core Current Transformer, KEPLER Current Transformer

*Price does not include VAT

KEPLER KCTM-24 V Split Core Current Transformer

KEPLER KCTM-24 V Split Core Current Transformer is a detachable core (Split Core CT) current transformer for measuring alternating current in electrical systems. It has a primary rated current of 200A and an output of 333mV AC at the rated current, suitable for use with measurement devices or meters that support a 333mV AC CT input.

The device is designed to allow opening and closing of the transformer core, making it easy to install around electrical conductors without needing to disconnect wires from their original connections. However, installation must be carried out under appropriate electrical safety measures.

Model KCTM-24 V belongs to the KEPLER KCTM-24V Series and has an output of 333mV AC, differing from transformers with a 5A output. Therefore, it should be used with devices that support this type of output.

General Features

  • Brand: KEPLER
  • Model: KCTM-24 V
  • Type: Split Core Current Transformer
  • Detachable core current transformer, can open the core for installation around conductors
  • Rated primary current: 200A AC
  • Rated output voltage: 333mV AC
  • Precision: Class 0.5 according to series data
  • Supports frequency range: 50-60Hz
  • Housing made of PC / UL94-V0 material
  • Suitable for measuring electrical current and energy monitoring systems

Technical Specifications (Technical Specifications)

BrandKEPLER
ModelKCTM-24 V
Product SeriesKCTM-24V Series
Product TypeSplit Core Current Transformer
Rated Primary Current200A AC
Rated Output333mV AC
Accuracy ClassClass 0.5 (Series Reference)
Frequency50-60Hz
Phase AngleLess than 2 degrees at 50% of rated current (Series Reference)
Insulation Voltage600VAC (Series Reference) Maximum Primary Voltage5000VAC, Insulated Conductor (Series Reference) Dielectric Strength2.5kV / 1mA / 1min (Series Reference) Operating Temperature-15 to +60°C Operating HumidityLess than 85% RH Case MaterialPC / UL94-V0 Bobbin MaterialPBT Core MaterialPermalloy Internal StructureEpoxy Lead WireUL1015, Twisted Pair, 22 AWG (Series Reference) Compatible Measurement Input333mV AC CT Input

How It Works

The Split Core Current Transformer operates based on the principle of electromagnetic induction. When alternating current flows through a conductor within the CT core, it generates a magnetic field that induces an electrical signal in the secondary winding.

For the KCTM-24 V model with a rating of 200A/333mV, the device is designed to have an output voltage rating of 333mV AC when there is a primary current of 200A AC. The output voltage changes in proportion to the measured current under the operating conditions specified by the manufacturer.

The 333mV AC output signal can be used with meters or measurement devices that have an input for CTs rated at 333mV, provided that the CT ratio is set correctly to 200A/333mV to ensure accurate readings.

Installation and Usage

  • Select the alternating current conductor you wish to measure the current of.
  • Install the CT by clamping it around a single wire of the circuit that needs to be measured.
  • Closure the split core completely according to the locking mechanism of the device.
  • Connect the signal wires to a meter that supports 333mV AC CT input.
  • Set the CT Ratio or CT Rating in the measuring equipment to match 200A/333mV.
  • Check the installation direction and polarity from the manufacturer's documentation.
  • Disconnect power sources and follow safety measures before installing.

Examples and Usage Guidelines

  • Measure electrical current in control panels and power distribution cabinets
  • Works with Energy Monitoring systems supporting 333mV CT input
  • Measures the load current of machinery and industrial electrical equipment
  • Adaptable for building energy consumption monitoring systems
  • Used in current measurement systems requiring open-CT installation

Important Considerations

  • This model is a 333mV AC output CT, not a 5A output CT
  • Meters or measuring devices supporting 333mV AC input must be used in conjunction with it
  • Check the current rating and measurement range to match actual usage requirements
  • Ensure that the CT core size is appropriate for the wire gauge
  • For general load current measurements, wrap the CT around a single conductor rather than both phase and neutral wires together
  • Verify CT Ratio settings and signal polarity before use
  • Some technical data references KCTM-24V Series; installation documentation specific to this model should be reviewed prior to installation
  • High voltage electrical system installations must be performed by qualified personnel following safety procedures
Write Your Own Review
You're reviewing:KCTM-24 V, 200A/333mV SPLIT CORE CURRENT TRANSFORMER KEPLER