Toggle Nav
My Cart 0

KAQ-56MG PORTABLE MULTI-GAS DETECTOR KEPLER

Price on request – please contact us
Out of stock
SKU
050979
Out of stock

The price for this item is not shown online yet.

Ask for a price on LINE

KEPLER SCMA

KAQ-56MG, KEPLER, Portable Multi-Gas Detector, Multi Gas Detector, Portable Gas Monitor, Industrial Multi-Gas Detector, Personal Gas Safety Monitor, Oxygen Gas Detector, O2 Detector, Carbon Monoxide Detector, CO Detector, Hydrogen Sulfide Detector, H2S Detector, Combustible Gas Detector, LEL Detector, Ammonia Gas Detector, NH3 Detector, Chlorine Gas Detector, Cl2 Detector, Smart Replaceable Sensor Module, Optional Built-in Sampling Pump, Intrinsically Safe Design, Audible Alarm, Visual Alarm, Vibration Alarm, Adjustable Alarm Setting, Span Calibration, Password Management, Self Test, Self Diagnostic, Self Correction, Real Time Clock, Industrial Gas Monitoring, Confined Space Gas Safety, Multi Gas Detector, Portable Gas Monitor, O2 CO H2S LEL NH3 Cl2 Gas Detector, Toxic Gas Detector, Flammable Gas Detector, Gas Alarm System, Replaceable Sensor Gas Meter, Optional Sampling Pump Gas Meter, KEPLER Gas Detector, KAQ-56MG Gas Detector, Industrial Gas Monitoring Device, Safety Gas Measurement Equipment

*Price does not include VAT

Portable Multi-Gas Detector KEPLER KAQ-56MG (KEPLER KAQ-56MG)

KEPLER KAQ-56MG Portable Multi-Gas Detector is a portable multi-gas detector designed for monitoring safety from toxic gases, flammable gases, and abnormal oxygen levels in the working environment. It is suitable for industrial plants, wastewater treatment systems, power plants, petrochemical industries, and areas with risks of dangerous gases.

The device supports usage with sensor modules for detecting various types of gases including Oxygen (O2), Carbon Monoxide (CO), Hydrogen Sulfide (H2S), Combustible Gas (LEL), Ammonia (NH3) and Chlorine (Cl2). The type and number of sensors to be used simultaneously must be checked according to the equipment set purchased.

The highlights of KAQ-56MG include a smart replaceable sensor module and an optional built-in sampling pump for gas sample collection, which helps in selecting appropriate measurements based on working conditions.

The device features three types of alerts: light, sound, and vibration. It also supports setting alert levels, span calibration adjustment, password management system, self-test function upon power-on, and self-diagnostic & self-correction system for checking the operational status of equipment.

General Features

  • Brand: KEPLER
  • Product Model: KAQ-56MG
  • Type of Product: Portable Multi-Gas Detector
  • Sensor modules support O2, CO, H2S, LEL, NH3 and Cl2 according to sensor selection
  • Uses a smart replaceable sensor module
  • Supports an optional built-in sampling pump for gas sample collection
  • Has alert systems with light, sound, and vibration
  • Can set alert level settings
  • Supports span calibration adjustment
  • Includes password management system (Password Management)
  • Includes automatic self-test function upon power-on (Self-Test After Power On)
  • Includes diagnostic and correction system for equipment issues (Self-Diagnostic & Self-Correction)
  • Has an internal Real-Time Clock (RTC)
  • Complies with intrinsically safe design according to catalog information
  • Suitable for industrial area gas inspection and safety work.
  • Technical Specifications

    Specifications Details
    BrandKEPLER
    ModelKAQ-56MG
    Product TypePortable Multi-Gas Detector
    Supported Gas TypesO2, CO, H2S, LEL, NH3, Cl2
    Simultaneous Gas ChannelsRefer to Selected Sensor Configuration
    Sensor ModuleSmart Replaceable Sensor Module
    Sampling PumpBuilt-in Sampling Pump (Optional)
    Alarm MethodVisual / Audible / Vibration
    Alarm SettingAdjustable
    Span CalibrationAdjustable
    Password ManagementSupported
    Self-TestAutomatic After Power On
    Self-DiagnosticSupported
    Self-CorrectionSupported
    Real-Time ClockBuilt-in
    Safety DesignIntrinsically Safe (Refer to Product Certification)
    Gas Measurement RangesDepending on Selected Sensor Modules
    Measurement AccuracyRefer to Manufacturer Datasheet
    Response TimeRefer to Manufacturer Datasheet
    Ingress ProtectionRefer to Manufacturer Datasheet
    Power Supply / BatteryRefer to Manufacturer Datasheet
    Dimensions / WeightRefer to Manufacturer Datasheet

    Supported Gas Types

    Gas Abbreviation Measurement Application
    Oxygen O2 Check oxygen level in the atmosphere
    Carbon Monoxide CO Monitor carbon monoxide gas
    Hydrogen Sulfide H2S Monitor hydrogen sulfide gas
    Combustible Gas LEL Check combustible gas concentration relative to the lower explosive limit
    Ammonia NH3 Monitor ammonia gas
    Chlorine Cl2 Monitor chlorine gas

    Note: The table shows the types of gases supported in the product line. It does not mean that a single device measures all six gases simultaneously; check the number of sensor channels, sensor type, and measurement range before ordering.

    Smart Replaceable Sensor Modules

    The KAQ-56MG supports replaceable smart sensor modules, allowing users to select and maintain sensors according to usage patterns. It is necessary to choose a suitable sensor type for the target gas and verify module compatibility with the device.

    When replacing sensor modules, it is essential to check installation procedures, settings, calibration, and operational testing as per the manufacturer's manual before putting the device back into use.

    Gas Sampling Pump System (Optional Sampling Pump)

    The device supports an optional built-in gas sampling pump for bringing gas samples from measurement locations to sensors according to the manufacturer’s specifications.

    Selecting and using a pump and sample collection equipment requires considering compatibility of the pump set, sample tubing, flow rate, and material suitability with respect to the measured gases, especially those sensitive to absorption or reaction with tubing materials.

    Alert System and Device Monitoring

    • Visual Alarm: Light alert when alarm conditions are met
    • Audible Alarm: Sound alert
    • Vibration Alarm: Vibration alert
    • Adjustable Alarm Setting: Adjustable alarm level settings according to usage
  • Self-Test: Automatically check the device's operation when turning on the machine.
  • Self-Diagnostic: Diagnose status and errors of the device.
  • Self-Correction: Support internal system-based error correction functions.
  • Password Management: Control access to related settings.
  • Real-Time Clock: Has an internal clock in the machine
  • Preparation Before Use

    • Check the product model and number of sensor modules installed in the machine.
    • Ensure that the gas type to be detected matches the sensor module.
    • Verify the measurement range, accuracy, and limitations of each sensor type.
    • Check the operational status and alert system before use.
    • Perform Bump Test and calibration according to manufacturer instructions and facility requirements.
    • Set appropriate alarm levels based on gas types and area risks.
    • If using a pump system, check flow rates and sampling equipment as per manual guidelines.
    • Check safety certification for hazardous areas before bringing the machine into such environments.
    • In case of an alert, follow emergency plans and facility safety procedures.

    Examples and Usage Guidelines

    • Monitor gases in industrial plants and production processes.
    • Watch over atmospheres in high-risk areas from toxic gases.
    • Use for air quality checks in confined spaces as per safety regulations.
    • Check gases in wastewater treatment systems.
    • Utilize for pipeline inspection and machinery maintenance work.
    • Monitor gases in petrochemical and oil industry plants.
    • Evaluate risks from flammable gases in industrial areas.
    • Apply to check ammonia or chlorine leaks when compatible sensors are selected.

    Safety Considerations

    • Select sensor types and quantities that match the gases being monitored.
    • A multi-gas detector does not mean it can detect all gas types without changing or selecting sensor modules.
    • The pump sampling system is an optional accessory; ensure it's included in your order.
    • Calibration and Bump Test should be performed according to specified procedures before use.
  • Must verify the Intrinsically Safe or Explosion Protection certification of the received product before using it in hazardous areas
  • Must check the measurement range and sensor sensitivity when changing the type of gas to be detected
  • The inspection of confined spaces must be carried out according to relevant safety regulations and procedures
  • The gas detector is a monitoring device and cannot replace safety precautions and environmental control measures
  • Should confirm power source details, IP rating, accessory equipment, and certification documents from the supplier before purchasing