KEPLER K2532 IN Analog Insulation Tester is an analog insulation resistance tester designed for testing the condition of electrical wires, electrical equipment, and power systems. It features three test voltage levels: 250V, 500V, and 1000VDC, capable of measuring up to a maximum insulation resistance of 400MΩ.
The device uses an analog meter display with Taut Band mechanism and mirror scale dial, reducing reading errors due to viewing angles. It includes continuity test function and AC voltage measurement up to 600VAC, suitable for electrical system inspection and maintenance work.
General Features
Brand: KEPLER
Model: K2532 IN
Type of Product: Analog Insulation Tester
Meter Display System: Analog Pointer Meter
Meter Mechanism: Taut Band Movement
Dial Face: Mirror Scale
Insulation Test Voltage: 250V / 500V / 1000VDC
Maximum Insulation Resistance Measurement Range: 400MΩ
Continuity Test Function: 3Ω / 500Ω
AC Voltage Measurement Function: 0-600VAC
Zero Ohm Adjustment System: Manual Zero Ω Adjustment
Discharge System: Automatic Discharge
Warning System: External Voltage Warning
Test Switch: Push and Lock Test Switch
Battery Supply: 6 x AA Batteries (1.5V each)
Insulation Resistance Measurement
Test Voltage: 250V / 500V / 1000VDC
Open Circuit Voltage: Rated Test Voltage +10%
Measurement Range: 0-100MΩ / 0-200MΩ / 0-400MΩ
Middle Scale Value: 1MΩ / 2MΩ / 4MΩ
Sensitivity Multiplier: ×1/2, ×1, ×2
Absolute Accuracy: ±5% of indicated value
Continuity Test
Measurement Range: 3Ω / 500Ω
Zero Adjustment: Adjust Zero Ω with the button on the unit
Output Fault Current: ≥200mA
Accuracy Value: ±1.5% of scale length
AC Voltage Measurement (AC Voltage)
Measurement Range: 0-600VAC
Accuracy Value: ±3% of scale length
Convenience and Safety Features
Automatic discharge system after insulation testing
External voltage detection warning system
Battery status check during use
Mirror Scale display to reduce reading errors from different viewing angles
Push-and-lock test switch for continuous testing
Manual Ohm Zero Adjustment button
Safety Standards
IEC/EN 61010-1 CAT III 600V
IEC/EN 61010-2-034
IEC/EN 61326-1
Examples and Usage Guidelines
Check the insulation resistance of electrical wiring
Inspect the insulation condition of electrical equipment and wiring systems
Apply for testing motor insulation according to appropriate test voltages
Verify continuity of electrical wires and circuits
Measure AC voltage before starting inspection work
Use in maintenance and inspection of building or industrial electrical systems
Limits and Considerations
Highest test insulation voltage 1000VDC
Select appropriate test voltages according to the insulation rating and equipment requirements
Disconnect power sources and ensure no residual voltage before testing insulation resistance
Await discharge circuit until safe condition after testing before touching the equipment
Voltage measurement supports AC voltage within specified range, does not specify DC voltage measuring function
Check probe conditions, battery status, and accessory details before use
Note: Technical data referenced from SCMA General Catalog Vol.5 Model K2532 IN, should follow manufacturer's manual and safety requirements for electrical system testing.