K2108 EL, KEPLER, AC/DC Analog Leakage Meter, Analog Leakage Current Meter, AC Leakage Meter, DC Leakage Meter, AC+DC Leakage Current Measurement, Electrical Leakage Tester, Analog Current Meter, Electrical Test Equipment, Leakage Current Meter, AC/DC Leakage Current Meter, Analog Leakage Meter, Electrical Leakage Testing Device, Small Size Electrical Meter, Industrial Electrical Measuring Tool
KEPLER K2108 EL AC/DC Analog Leakage Meter is an analog leakage current meter designed for measuring small electrical currents. It supports the measurement of direct current (DC Current), alternating current (AC Current), combined AC+DC current, and alternating voltage (AC Voltage).
The meter uses an analog pointer display system with a Taut Band Movement mechanism to show measurement values and includes overload protection circuitry. This makes it suitable for electrical leakage testing, equipment testing, and electrical system inspections in engineering work.
Features and Technical Data
Brand: KEPLER
Model: K2108 EL
Type of Product: AC/DC Analog Leakage Meter
Display System: Analog Pointer Meter
Meter Mechanism: Taut Band Movement
Measurement Functions: DC Current, AC Current, AC+DC Current, AC Voltage
Accuracy: ±2.5% of full scale
Input Resistance for Current Measurement: 1kΩ / 1.5kΩ / 2kΩ
Operating Frequency Range: 20Hz-5kHz
Protection System: Built-in Overload Protection
Battery Supply: 8 x 1.5V (AA) batteries
Operating Temperature: 0 to 40°C
Operating Humidity: Up to 80% RH
Dimensions: 210 x 210 x 100 mm
Total Weight with Batteries: Approximately 1395 g
Measurement Ranges (Ranges)
1. Direct Current (DC Current)
Range: 0.1 / 1 / 10 mA
2. Alternating Current (AC Current)
Range: 0.1 / 1 / 10 mA
3. Combined AC+DC Current (AC+DC Current)
Range: 0.1 / 1 / 10 mA
4. Alternating Voltage (AC Voltage)
Range: 150 / 300 V
Frequency for AC voltage range: 50/60Hz
Input Resistance at 150V: 500kΩ
Input impedance at 300V: 1MΩ
Features
Suitable for measuring AC and DC current
Has an AC+DC current measurement mode
Offers three levels of input resistance range for current measurement
Displays measurement results with an analog needle
Includes overcurrent protection circuitry inside the unit
Safety Standards
EN 61010-1 CAT III 600V
Examples and Usage Guidelines
To measure electrical leakage current of electrical equipment
To check small AC and DC currents in test circuits
To check AC+DC current
To measure alternating voltage according to the instrument's measurement range
For use in electrical equipment testing laboratories
To be applied for inspection and maintenance of electrical equipment
Limits and Considerations
The highest current measurement range specified is 10mA, not suitable for measuring high load currents
Voltage measurement supports AC voltage according to the specified range, does not specify DC voltage measurement function
Leakage current measurement must connect test circuits as per methods defined in the manual
The tool is not a clamp meter for non-invasive current measurement without connecting to the circuit
Should verify circuit type and voltage level match the instrument's safety rating
Should confirm accessory details and testing conditions before ordering
Note: Technical data referenced from Standard Electric Works' basic model 2108 EL document. Should cross-check with KEPLER K2108 EL before publishing or setting actual test conditions.