K1020 IN, KEPLER, Digital High Voltage Insulation Tester, 10kV Insulation Tester, High Voltage Insulation Resistance Meter, Digital Megohmmeter, 10000V Insulation Tester, 20TΩ Insulation Tester, High Voltage Megger, Insulation Resistance Tester, PI DAR Insulation Tester, Insulation Resistance Tester, High Voltage Insulation Tester, 10kV Insulation Tester, Digital Insulation Meter, 10000V Insulation Tester, Industrial Insulation Resistance Tester
High Voltage Digital Insulation Tester KEPLER Model K1020 IN (10kV)
KEPLER K1020 IN Digital High Voltage Insulation Tester is a digital high voltage insulation tester designed for testing the insulation condition of electrical equipment and high-voltage power systems. It supports a maximum test voltage of 10,000VDC (10kV) with an insulation resistance measurement range up to 20TΩ under specified conditions.
The device features a large color display for showing measurement results, supporting analysis functions such as IR, IR(t), DAR, PI, SV, DD and Ramp Test. It can display and record insulation resistance values, test voltage, and current during testing, along with date and time logging, and data export via USB.
General Features
Brand: KEPLER
Model: K1020 IN
Type of Product: Digital High Voltage Insulation Tester
Maximum Test Voltage: 10,000VDC (10kV)
Test Voltage Range: 500V / 1000V / 2500V / 5000V / 10000V
Adjustable Test Voltage: User Defined Test Voltage
Maximum Insulation Resistance Measurement Range: 20TΩ at test voltage of 10kV
Display: Large Color Display
Insulation Analysis Functions: IR, IR(t), DAR, PI, SV, DD and Ramp Test
Data Logging: Measurement results with date and time logging
Data Communication: USB
Casing Style: Dual Case
Power Supply: Internal Battery and AC Power Source
Test Voltage Settings (Test Voltage)
Standard Test Voltages: 500V / 1000V / 2500V / 5000V / 10000V
Voltage Adjustment from 100V to 1kV: Adjust in increments of 10V
Voltage Adjustment from 1kV to 10kV: Adjust in increments of 25V
Test Voltage Accuracy: +4%, -0%, ±10V as specified in the catalog at a load of 1GΩ and temperature range of 0-30°C
Insulation Resistance Measurement Range (IR)
Test Voltage
Measurement Range / Accuracy ±5%
Measurement Range / Accuracy ±20%
500V
0.4MΩ-100GΩ
100GΩ-1TΩ
1000V
0.8MΩ-200GΩ
200GΩ-2TΩ
2500V
2MΩ-500GΩ
500GΩ-5TΩ
5000V
4MΩ-1TΩ
1TΩ-10TΩ
10000V
8MΩ-2TΩ
2TΩ-20TΩ
Electrical Measurement Data
Short Circuit Current: 6mA
AC/DC Voltage Measurement: 30-660V
Frequency for AC Measurement: 45-65Hz
Voltage Measurement Accuracy: ±(2%rdg+3V)
Current Measurement Range: 0.01nA-8.00mA
Current Measurement Accuracy: ±(2%rdg+0.5nA)
Capacitance Measurement Range: 5.0nF-50.0µF
Capacitance Measurement Accuracy: ±(5%rdg+5nF)
Insulation Resistance Analysis Functions
IR: Insulation Resistance Measurement
IR(t): Time-Dependent Insulation Resistance Check
DAR: Dielectric Absorption Ratio
PI: Polarization Index
SV: Step Voltage Test
DD: Dielectric Discharge
Ramp Test: Voltage Level Change Testing Based on Test Pattern
Data Logging and Management
Show real-time changes in insulation resistance, voltage, and current during testing
Support data logging with date and time stamps
Support data export via USB
Color display for checking measured values and test results
Power Supply and Environment
AC Power Supply: 85-264VAC, 45-65Hz
Battery Capacity: 5200mAh
Operating Temperature Range: -20 to 50°C
Operating Humidity: Less than 95% RH without condensation
Protection Level: IP65 with cover closed / IP40 with cover open
Examples and Usage Guidelines
Inspect the insulation resistance of high-voltage power cables
Check the condition of motor windings and generators
Test the insulation of transformers using appropriate testing methods
Apply for inspection and maintenance of industrial electrical systems
Analyze insulation trends with PI, DAR functions and time-based measurements
Record test results to compile reports on electrical system inspections
Limits and Considerations
The maximum test voltage of K1020 IN is 10kV, not 12kV
The highest measurement range of 20TΩ is accurate ±20% in the range of 2TΩ-20TΩ at a test voltage of 10kV
Select an appropriate test voltage based on the type and insulation rating of the equipment
Disconnect power sources and verify that there is no residual voltage before testing insulation
After testing, ensure that any stored electrical charge in the device has been safely discharged before touching it
Use measurement leads and accessories rated for the test voltage as specified by the manufacturer
High-voltage systems should be handled by trained personnel with knowledge of safety procedures
Note: Technical data referenced from SCMA General Catalog Vol.5, model K1020 IN excluding 12kV test voltage and 24TΩ measurement range which are features of the K1224 IN model.
We use cookies to make the site work properly, to understand how it is used, and to show content that is relevant to you. You choose which types to allow; strictly necessary cookies are always on. Privacy Policy