F10 Probe, KEPLER, Optional Probe for KC-Series, F10 Coating Thickness Probe, Ferrous Coating Thickness Probe, Magnetic Induction Probe, High Range Coating Thickness Probe, Thick Coating Thickness Measurement, Coating Thickness Gauge Probe, Paint Thickness Gauge Probe, Replacement Coating Thickness Probe, Industrial Coating Thickness Sensor, Dry Film Thickness Probe, DFT Probe, Steel Coating Thickness Probe, Ferrous Substrate Coating Gauge, 0-10000um Coating Thickness Probe, 0-10mm Coating Thickness Probe, 1um Resolution, Magnetic Coating Thickness Measurement, KC-Series Optional Probe, KC-200 Series Probe, KC-2605 F10 Probe, Protective Coating Inspection, Industrial Paint Thickness Measurement, Non Destructive Coating Inspection, Coating Quality Control, Coating Thickness Measuring Head F10, Paint Thickness Measuring Head F10, Additional Paint Thickness Measuring Head, Wide Range Paint Thickness Measuring Head, 10000 Micron Coating Thickness Measuring Head, 10mm Coating Thickness Measuring Head, Ferrous Measuring Head, Magnetic Induction Measuring Head, Steel Surface Paint Thickness Measuring Head, Thick Coating on Steel Measuring Head, Dry Film Thickness Measuring Head, Replacement Paint Thickness Measuring Head, KEPLER F10 Measuring Head, KC-Series KEPLER Measuring Head, Protective Coating Inspection Tool

*Price does not include VAT

KEPLER F10 Probe Head (Optional Probe for KC-Series)

KEPLER F10 Probe is an optional probe head for the KEPLER KC-Series Coating Thickness Gauge, designed to measure non-magnetic coatings on ferrous substrates such as steel and iron using magnetic induction principles.

The F10 probe supports a measurement range of 0-10000 µm or 0-10 mm, suitable for measuring thicker coatings than some standard probes. It is ideal for industrial paint thickness inspection, anti-corrosion coating materials, and other compatible coated materials.

According to the SCMA General Catalog Vol.5, the F10 probe has a minimum resolution of 1 µm and an accuracy of ±(1%H + 5 µm), where H is the measured coating thickness. The measurement results depend on the gauge used, calibration methods, substrate properties, and surface condition.

Features

  • Brand: KEPLER
  • Probe Model: F10
  • Product Type: Optional Coating Thickness Gauge Probe
  • Ferrous (F) probe type
  • Magnetic Induction measurement principle
  • For non-magnetic coatings on steel substrates
  • Measurement range 0-10000 µm or 0-10 mm
  • Minimum resolution of 1 µm
  • Absolute accuracy ±(1%H + 5 µm) as per F10 probe table
  • Minimum convex radius of curvature 10 mm
  • Minimum measurement area diameter 40 mm
  • Minimum substrate thickness 2 mm
  • Suitable for measuring thick coatings
  • Can be used as an optional or replacement probe head for compatible gauges
  • F10 data available in the KC-200 and KC-2605 series according to the catalog

Technical Specifications

Specifications Details
BrandKEPLER
Probe ModelF10
Product TypeOptional Coating Thickness Gauge Probe
Probe TypeFerrous (F)
Measurement PrincipleMagnetic Induction
Measuring Range0-10000 µm
Measuring Range (mm)0-10 mm
Minimum Resolution1 µm
Measurement Tolerance±(1%H + 5 µm)
Minimum Convex Curvature Radius10 mm
Minimum Measuring Area DiameterØ40 mm
Critical Thickness of Substrate2 mm
Suitable SubstrateFerrous / Magnetic Metal
Suitable CoatingNon-Magnetic Coating on Ferrous Substrate
Related Gauge SeriesKC-200 Series / KC-2605 (Verify Compatibility)
Connection TypeRefer to Compatible Gauge and Probe Specification
Measurement Unitµm / mm

Note: H refers to the thickness of the coating being measured. The deviation values and geometric limitations above refer to data from the F10 probe in the KC-2605 catalog table. Additional compatibility and performance checks are required for use with other models.

Working Principle of F10 Magnetic Induction Probe

The F10 probe uses magnetic induction principles to measure the distance between the probe tip and a ferromagnetic base material, where this distance is proportional to the thickness of the non-magnetic coating on the workpiece surface.

When placing the probe onto the coated surface, the measuring instrument processes signals from the probe and displays the thickness value based on predefined calibration settings.

Magnetic measurement with a ferrous probe is suitable for iron or steel base materials but not directly applicable to aluminum or non-ferrous metal bases. For coating measurements on such substrates, probes N or FN should be selected.

Highlights of the 0-10000 µm Measuring Range

The F10 probe has a maximum measuring range of 10000 µm or 10 mm, allowing for the inspection of thicker coatings than what is supported by the F1 probe, which covers a measurement range of 0-1250 µm according to the catalog data.

However, the F10 probe has different requirements regarding measuring area size and base material thickness compared to probes with lower measurement ranges. Users should check the shape and size of the workpiece before selecting this probe.

Compatibility with KEPLER KC-Series

The SCMA General Catalog Vol.5 specifies that F10 is a Ferrous type accessory in the Optional Accessories list for the KC-200 Series group, and includes technical data tables for F10 under the probe section for the KC-2605 machine.

Using the F10 probe with each model requires checking the connector compatibility, probe setup settings, and measurement range capabilities. Being part of the same KC-Series does not guarantee that all versions can be used together immediately.

Calibration

The measuring instrument should be calibrated along with the F10 probe using a Ferrous reference base material and Calibration Foil or an appropriate thickness standard for the measurement range.

Calibration must follow the supported steps of the measuring device, and accuracy should be verified on reference workpieces before actual measurements, especially when changing probes or base material types.

Selecting the F10 Probe

  • Check if your Coating Thickness Gauge supports the F10 probe.
  • Verify connector compatibility and probe setup settings.
  • Confirm that the workpiece has a magnetic metal base material.
  • Ensure coating thickness is within 0-10000 µm range.
  • Check that the workpiece convex radius meets or exceeds 10 mm as specified.
  • Verify that the measuring area diameter is at least 40 mm.
  • Confirm base material thickness of no less than 2 mm.
  • Clean the surface of the workpiece before measurement.
  • Calibrate the instrument with an appropriate reference material.
  • Position the probe to contact the surface correctly.
  • Repeat measurements according to quality inspection plans.
  • Properly store the probe and signal cables after use.

Examples and Usage Guidelines (Applications)

  • Measure coating thickness on steel sheets.
  • Inspect industrial paint thickness on steel substrates.
  • Evaluate corrosion-resistant coatings suitable for measurement principles.
  • Check coating thickness on machine parts.
  • Measures coating thickness beyond the standard probe range
  • Checks surface coatings during production processes
  • Used for industrial quality control of surface coatings
  • Serves as an additional or replacement probe for compatible instruments
  • Considerations Before Purchase

    • The product is the F10 probe, not a complete Coating Thickness Gauge set
    • F10 is a Ferrous type probe using Magnetic Induction principle
    • Measurement range 0-10000 µm, different from F1 or F400 probes' ranges
    • Must check compatibility with the actual KC-Series model in use
    • The measurement area and base material properties are crucial to the results
    • Precision depends on the gauge, probe calibration, and workpiece condition
    • Do not use the probe with Non-Ferrous base materials without verifying appropriate measuring principles
    • Ensure that the thickness of the calibration foil matches the intended usage range
    • Do not include dimensions, weight, battery, or memory specifications of the gauge as F10 probe specs
    • Check product codes, shipping items, and warranty conditions before purchasing
    Write Your Own Review
    You're reviewing:F10 Probe OPTIONAL PROBE FOR KC-SERIES KEPLER
    Cookie settings
    🤖 AI Assistant
    Ask about products, specs and replacement models
    Hello 👋 Ask us anything — find products, compare specs, or troubleshoot.
    🗑 Clear history