KEPLER F10 Probe Head (Optional Probe for KC-Series)
KEPLER F10 Probe is an optional probe head for the KEPLER KC-Series Coating Thickness Gauge, designed to measure non-magnetic coatings on ferrous substrates such as steel and iron using magnetic induction principles.
The F10 probe supports a measurement range of 0-10000 µm or 0-10 mm, suitable for measuring thicker coatings than some standard probes. It is ideal for industrial paint thickness inspection, anti-corrosion coating materials, and other compatible coated materials.
According to the SCMA General Catalog Vol.5, the F10 probe has a minimum resolution of 1 µm and an accuracy of ±(1%H + 5 µm), where H is the measured coating thickness. The measurement results depend on the gauge used, calibration methods, substrate properties, and surface condition.
Features
- Brand: KEPLER
- Probe Model: F10
- Product Type: Optional Coating Thickness Gauge Probe
- Ferrous (F) probe type
- Magnetic Induction measurement principle
- For non-magnetic coatings on steel substrates
- Measurement range 0-10000 µm or 0-10 mm
- Minimum resolution of 1 µm
- Absolute accuracy ±(1%H + 5 µm) as per F10 probe table
- Minimum convex radius of curvature 10 mm
- Minimum measurement area diameter 40 mm
- Minimum substrate thickness 2 mm
- Suitable for measuring thick coatings
- Can be used as an optional or replacement probe head for compatible gauges
- F10 data available in the KC-200 and KC-2605 series according to the catalog
Technical Specifications
| Specifications |
Details |
| Brand | KEPLER |
| Probe Model | F10 |
| Product Type | Optional Coating Thickness Gauge Probe |
| Probe Type | Ferrous (F) |
| Measurement Principle | Magnetic Induction |
| Measuring Range | 0-10000 µm |
| Measuring Range (mm) | 0-10 mm |
| Minimum Resolution | 1 µm |
| Measurement Tolerance | ±(1%H + 5 µm) |
| Minimum Convex Curvature Radius | 10 mm |
| Minimum Measuring Area Diameter | Ø40 mm |
| Critical Thickness of Substrate | 2 mm |
| Suitable Substrate | Ferrous / Magnetic Metal |
| Suitable Coating | Non-Magnetic Coating on Ferrous Substrate |
| Related Gauge Series | KC-200 Series / KC-2605 (Verify Compatibility) |
| Connection Type | Refer to Compatible Gauge and Probe Specification |
| Measurement Unit | µm / mm |
Note: H refers to the thickness of the coating being measured. The deviation values and geometric limitations above refer to data from the F10 probe in the KC-2605 catalog table. Additional compatibility and performance checks are required for use with other models.
Working Principle of F10 Magnetic Induction Probe
The F10 probe uses magnetic induction principles to measure the distance between the probe tip and a ferromagnetic base material, where this distance is proportional to the thickness of the non-magnetic coating on the workpiece surface.
When placing the probe onto the coated surface, the measuring instrument processes signals from the probe and displays the thickness value based on predefined calibration settings.
Magnetic measurement with a ferrous probe is suitable for iron or steel base materials but not directly applicable to aluminum or non-ferrous metal bases. For coating measurements on such substrates, probes N or FN should be selected.
Highlights of the 0-10000 µm Measuring Range
The F10 probe has a maximum measuring range of 10000 µm or 10 mm, allowing for the inspection of thicker coatings than what is supported by the F1 probe, which covers a measurement range of 0-1250 µm according to the catalog data.
However, the F10 probe has different requirements regarding measuring area size and base material thickness compared to probes with lower measurement ranges. Users should check the shape and size of the workpiece before selecting this probe.
Compatibility with KEPLER KC-Series
The SCMA General Catalog Vol.5 specifies that F10 is a Ferrous type accessory in the Optional Accessories list for the KC-200 Series group, and includes technical data tables for F10 under the probe section for the KC-2605 machine.
Using the F10 probe with each model requires checking the connector compatibility, probe setup settings, and measurement range capabilities. Being part of the same KC-Series does not guarantee that all versions can be used together immediately.
Calibration
The measuring instrument should be calibrated along with the F10 probe using a Ferrous reference base material and Calibration Foil or an appropriate thickness standard for the measurement range.
Calibration must follow the supported steps of the measuring device, and accuracy should be verified on reference workpieces before actual measurements, especially when changing probes or base material types.
Selecting the F10 Probe
- Check if your Coating Thickness Gauge supports the F10 probe.
- Verify connector compatibility and probe setup settings.
- Confirm that the workpiece has a magnetic metal base material.
- Ensure coating thickness is within 0-10000 µm range.
- Check that the workpiece convex radius meets or exceeds 10 mm as specified.
- Verify that the measuring area diameter is at least 40 mm.
- Confirm base material thickness of no less than 2 mm.
- Clean the surface of the workpiece before measurement.
- Calibrate the instrument with an appropriate reference material.
- Position the probe to contact the surface correctly.
- Repeat measurements according to quality inspection plans.
- Properly store the probe and signal cables after use.
Examples and Usage Guidelines (Applications)
- Measure coating thickness on steel sheets.
- Inspect industrial paint thickness on steel substrates.
- Evaluate corrosion-resistant coatings suitable for measurement principles.
- Check coating thickness on machine parts.
Measures coating thickness beyond the standard probe range
Checks surface coatings during production processes
Used for industrial quality control of surface coatings
Serves as an additional or replacement probe for compatible instruments
Considerations Before Purchase
- The product is the F10 probe, not a complete Coating Thickness Gauge set
- F10 is a Ferrous type probe using Magnetic Induction principle
- Measurement range 0-10000 µm, different from F1 or F400 probes' ranges
- Must check compatibility with the actual KC-Series model in use
- The measurement area and base material properties are crucial to the results
- Precision depends on the gauge, probe calibration, and workpiece condition
- Do not use the probe with Non-Ferrous base materials without verifying appropriate measuring principles
- Ensure that the thickness of the calibration foil matches the intended usage range
- Do not include dimensions, weight, battery, or memory specifications of the gauge as F10 probe specs
- Check product codes, shipping items, and warranty conditions before purchasing