KEPLER F1 Probe (Optional Probe for KC-Series)
KEPLER F1 Probe is an optional and replacement probe head for KEPLER KC-Series coating thickness gauges that support the F1 probe. It uses magnetic induction principles to measure the thickness of non-magnetic coatings on ferrous substrates such as steel and stainless steel.
The F1 probe supports a measurement range of 0-1250 µm with a resolution of 0.1 µm, making it suitable for inspecting coating thicknesses like paint films and other materials compatible with magnetic induction principles when used in conjunction with compatible gauges such as KC-200F1 and KC-270F1 according to the SCMA General Catalog Vol.5.
The separate probe head increases convenience for checking various positions on workpieces and can serve as a replacement part when the original probe is damaged or needs replacing, provided that the connector type and compatibility with the gauge are verified before purchase.
Features
- Brand: KEPLER
- Probe Model: F1
- Product Type: Optional Coating Thickness Gauge Probe
- Ferrous (F) probe type
- Magnetic Induction principle used
- For measuring non-magnetic coatings on steel substrates
- Measurement range 0-1250 µm
- Resolution 0.1 µm
- Suitable for paint thickness and coating inspections
- Usage with KC-270F1 specifies a minimum convex radius of curvature of 1.5 mm
- Usage with KC-270F1 specifies a minimum measurement area diameter of 7 mm
- Usage with KC-270F1 specifies a minimum substrate thickness of 0.5 mm
- Serves as an optional or replacement probe for compatible KC-Series models
- Fits well for paint thickness inspection and coating quality control work
Technical Specifications of the Probe
| Specifications |
Details |
| Brand | KEPLER |
| Probe Model | F1 |
| Product Type | Optional Coating Thickness Gauge Probe |
| Probe Type | Ferrous (F) |
| Measurement Principle | Magnetic Induction |
| Measuring Range | 0-1250 µm |
| Resolution | 0.1 µm |
| Substrate Type | Ferrous / Magnetic Metal |
| Suitable Coating | Non-Magnetic Coatings on Ferrous Substrates |
| Minimum Convex Curvature Radius | 1.5 mm (KC-270F1 Specification) |
| Minimum Measuring Area Diameter | 7 mm (KC-270F1 Specification) |
| Critical Substrate Thickness | 0.5 mm (KC-270F1 Specification) |
| Related Gauge Models | KC-200F1 / KC-270F1 |
| Other KC-Series Compatibility | Subject to Confirmation |
Measurement Accuracy by Model
The measurement accuracy depends on the instrument used with the probe, calibration method, and measuring conditions. The catalog specifies the following data:
| Gauge Model |
Accuracy / Tolerance |
| KC-200F1 |
±(3%H + 1) µm |
| KC-270F1 - Zero Point Calibration |
±(3%H + 1) µm |
| KC-270F1 - Two Point Calibration |
±[(1-3)%H + 1] µm |
Note: H refers to the thickness of the coating being measured. The accuracy data above is for the system gauge with probe as per the catalog, not the accuracy of the F1 probe when used independently.
Principle of Magnetic Induction Probe
The F1 probe uses magnetic induction principles to measure the thickness of non-magnetic coatings on ferrous substrates by detecting changes in magnetic signal related to the distance between the probe and the substrate.
When the probe is placed on the coating layer, the compatible measuring instrument processes signals from the probe and displays the thickness according to the calibration settings.
The F-type probe is not suitable for measuring coatings on Non-Ferrous base materials such as aluminum directly. If you need to measure on these types of substrates, choose the N or FN probes that are compatible with your instrument and coating type.
Usage with KEPLER KC-Series Instruments
The catalog specifies F1 as the standard probe for the KC-200F1 and KC-270F1 models, both having a measurement range of 0-1250 µm.
Before using the F1 Probe as a replacement probe, check the connector type and electrical specifications of your instrument. Using the same probe name does not guarantee that all versions can be interchanged directly between different models.
Calibration
The use of an F1 Probe should follow calibration procedures outlined in the manual using Ferrous reference substrates and appropriate Calibration Foil for the thickness range of your work.
The KC-270F1 supports Zero and Foil Calibration as per the catalog information. For setup and calibration steps of other models, refer to the specific model manuals.
Check values on reference materials before starting actual measurements and recalibrate when changing probes or if there are significant changes in usage conditions.
Usage Examples (Applications)
- Checking paint thickness on steel sheets
- Measuring coating thickness on steel parts
- Metering dry film thickness (Dry Film Thickness)
- Inspecting industrial painting work
- Checking coatings on machine components
- Measuring paint thickness during quality control processes
- Serving as a replacement probe for compatible KC-Series instruments
- Used in surface coating quality inspection work
Instrument Preparation and Measurement Guidelines
- Ensure that your instrument supports the F1 probe.
- Check connectors and probe cables before use.
- Confirm that the workpiece has a magnetic base material.
- Verify that the coating thickness range is within 0-1250 µm.
- Clean the surface of the workpiece before measurement.
- Use reference substrates and Calibration Foil for calibration.
- Follow instrument manual procedures for calibration.
- Position the probe to touch the surface correctly.
- Repeat measurements at specified positions and number of points.
- Clean and store the probe after use.
Considerations Before Purchase
- This item is an F1 probe, not a complete Coating Thickness Gauge set
- F1 is a Ferrous type Magnetic Induction probe
- It is not the N1 probe for Non-Ferrous base metals
- The measurement range is 0-1250 µm, not the 0-400 µm of F400 or 0-10000 µm of F10
- Compatibility with other KC-Series models must be verified before ordering a probe
- The accuracy depends on the gauge and calibration method used
- Curb radius, measurement area, and base material thickness should be checked
- The dimensions, weight, battery, or memory of the instrument should not be considered as specifications for the probe
- Check the delivery item list and warranty conditions with the supplier before ordering