KEPLER F1/90 Probe (Optional Probe for KC-Series)
KEPLER F1/90 Probe is an optional probe for KEPLER KC-Series Coating Thickness Gauge that supports the F1/90 probe type. It is designed as a right-angle probe (90-degree angle) to increase convenience in measuring coating thickness in areas with limited space or access.
The F1/90 probe is of Ferrous (F) type, using magnetic induction measurement principles for measuring non-magnetic coatings on ferromagnetic substrates such as steel and iron. It is suitable for tasks involving the inspection of paint thickness, film coating, and surface coating in manufacturing processes and quality control.
According to technical data from the F1/90 probe of the same type, it has a measurement range of 0-1250 µm with a resolution of 0.1 µm. The SCMA catalog confirms that the F1/90 is an accessory in the KC-200 Series group. However, before purchasing, one should confirm the actual measurement range and probe details of the delivered product.
Features
- Brand: KEPLER
- Probe Model: F1/90
- Product Type: Optional Coating Thickness Gauge Probe
- Ferrous (F) type probe
- Designed as a right-angle probe (90-degree angle)
- Magnetic Induction measurement principle
- Suitable for measuring non-magnetic coatings on steel substrates
- The reference measurement range of the F1/90 probe is 0-1250 µm
- Reference resolution: 0.1 µm
- Suitable for inspection in areas with limited access
- Can be used as an accessory or replacement probe for compatible gauges
- Listed as an accessory for the KC-200 Series according to the SCMA catalog
- Mate compatibility and connectivity of the probe should be checked before purchasing
Technical Specifications
| Specifications |
Details |
| Brand | KEPLER |
| Probe Model | F1/90 |
| Product Type | Optional Coating Thickness Gauge Probe |
| Probe Type | Ferrous (F) |
| Probe Design | Right-Angle / 90 Degrees |
| Measuring Principle | Magnetic Induction |
| Measuring Range | 0-1250 µm (Reference Specification; Verify with Supplied Probe) |
| Resolution | 0.1 µm (Reference Specification; Verify with Supplied Probe) |
| One-Point Calibration Accuracy | ±(3%H + 1) µm (Reference Specification) |
| Two-Point Calibration Accuracy | ±[(1-3)%H + 1] µm (Reference Specification) |
| Minimum Measuring Area Diameter | Ø7 mm (Reference Specification) |
| Critical Substrate Thickness | 0.5 mm (Reference Specification) |
| Suitable Substrate | Ferrous / Magnetic Metal |
| Suitable Coating | Non-Magnetic Coating on Ferrous Substrate |
| Related Gauge Series | KEPLER KC-200 Series |
| Compatibility with Other KC-Series | Subject to Confirmation |
Note: The Measuring Range, Resolution, Accuracy and measurement conditions specified are reference specifications for the F1/90 probe of the same type. Since SCMA Catalog Vol.5 confirms the probe name and accessory status but does not specify all sub-specifications of the F1/90 directly, H refers to the thickness of the coating being measured.
Principle of Operation of Magnetic Induction Probe
The F1/90 probe operates on the principle of magnetic induction by utilizing changes in a magnetic field that are related to the distance between the probe and the ferromagnetic substrate material.
When placed on a surface with coating, the measuring instrument processes signals from the probe to calculate the thickness of the coating based on the calibration values provided.
Magnetic (Ferrous) probes are suitable for substrates such as steel or stainless steel but are not appropriate for measuring coatings on aluminum substrates using the same principle. If non-ferromagnetic metal measurement is required, an N or FN probe compatible with the material and instrument should be selected.
Features of the Right-Angle Probe
The F1/90 has a probe tip design that differs from standard straight probes, with the probe head or cable connection oriented at a right angle. This allows users to access certain measurement positions more easily.
It is suitable for use in areas with limited space, such as metal part corners, near workpiece edges, or locations where it's inconvenient to use a straight probe tip. Ensure that the probe face can properly contact the surface being measured.
Compatibility with KEPLER KC-Series
The SCMA General Catalog Vol.5 specifies F1/90 as a Ferrous Probe in the Optional Accessories list for the KC-200 Series measuring instruments, where model KC-200F1 uses Magnetic Induction principles to measure coating thickness on magnetic metal substrates.
Before purchasing the F1/90 probe, check your instrument model number, connector type, and probe compatibility with the supplier since the KC-Series covers multiple models that may have different probe connection systems.
Calibration
The measuring instrument should be calibrated together with the F1/90 probe before use. Use a Ferrous reference base material and standard calibration foil appropriate for the desired thickness range.
Zero and Two-Point calibrations are methods used in coating thickness measurement systems, following specific model manuals and verifying measurements against reference materials before starting actual work.
Applications
- Measuring paint thickness on steel parts
- Checking coating thickness on steel components
- Measuring dry film thickness (Dry Film Thickness)
- Inspecting workpieces in areas with space limitations
- Checking coatings on machine parts
- Verifying paint thickness in industrial painting jobs
- Evaluating surface coating quality during production processes
- Serving as an additional or replacement probe for compatible KC-Series instruments
Tips for Selecting and Using Probes
- Check if your instrument model supports the F1/90 Probe
- Verify the connector type and size of the probe
- Confirm that the workpiece has a Ferrous base material
- Evaluate the coating thickness range to be measured
- Consider the contact area and reachability of the 90-degree probe tip
Check for smoothness, curvature, and measurement area size
Clean the surface of the workpiece before measuring
Use Calibration Foil and appropriate reference materials
Calibrate the instrument after installing the probe according to the manufacturer's instructions
Position the probe to properly contact the workpiece surface
Repeat measurements as per quality inspection plan
Properly store the probe and signal cables after use
Considerations Before Purchase
- This item is an F1/90 Probe, not a complete Coating Thickness Gauge set
- The F1/90 Probe is a Ferrous type Magnetic Induction probe
- The F1/90 Probe is designed at a 90-degree angle, different from the straight F1 Probe
- Do not use the F1/90 Probe to measure on Non-Ferrous base materials without verifying supported measurement principles
- Mutual compatibility must be confirmed with the actual KC-Series instrument in use
- The measuring range and accuracy must be verified with the actually shipped F1/90 probe
- Accuracy depends on the meter, calibration, and workpiece surface condition
- Check access position and probe placement orientation before selecting for use
- Avoid using specifications of F10 or F400 to replace F1/90
- Review equipment list and warranty conditions before purchasing