SANGI SG-FUMD-63-GF Clamp-on Ultrasonic Flow Transmitter for DN63 Glassfiber Pipe
SANGI SG-FUMD-63-GF Clamp-on Ultrasonic Flow Transmitter is a liquid flow sensor using ultrasonic (Ultrasonic) technology that can be installed externally on pipes without the need to cut or modify the pipe for flow measurement. This model is specified for use with DN63 Glassfiber Pipe.
The SG-FUMD series features an OLED display and supports Analog Current 4-20mA output signals as well as RS485 Modbus RTU communication, making it suitable for monitoring liquid flow in industrial pipe systems and control systems that support these signals.
Installation Method: External pipe installation without cutting the pipe
Pipe Size for this Model: DN63
Pipe Material for this Model: Glassfiber (Fiberglass)
Used to measure liquid flow rate
Display Type: OLED Display
Technical Specifications
Model
SG-FUMD-63-GF
Brand
SANGI
Pipe Size
DN63
Pipe Material
Glassfiber
Measurement Principle
Ultrasonic
Measurement Accuracy
±2%
Medium Temperature
0 ~ 50°C
Analog Output
4-20mA
Communication
RS485 Modbus RTU
Measurement Units
m3/h, L/h, GAL/h, m3/min, L/min, GAL/min
Display
OLED Display
Protection Rating
IP54
Power Supply
24VDC
Pipe Size and Installation
SG-FUMD-63-GF is the model specified for DN63 fiberglass pipe, using an external Clamp-on installation method without the need to cut or splice the pipe. It is important to verify the actual pipe size, wall thickness, and surface condition at the installation site before use.
Examples and Usage Guidelines
Monitor the flow rate of liquid inside DN63 fiberglass pipes
Apply in industrial plant liquid circulation systems
Apply in fiberglass pipe systems that require flow monitoring without cutting or splicing the pipe
Send 4-20mA flow rate signals to compatible control systems
Connect data via RS485 Modbus RTU with compatible monitoring or control devices
Considerations
Select the model that matches the pipe size and material, as SG-FUMD-63-GF is specified for DN63 fiberglass pipes
The temperature range of liquid specified for the SG-FUMD series is 0 ~ 50°C
It is important to verify the suitability of the fiberglass pipe structure, wall thickness, and surface condition before actual installation
Check the compatibility of the Analog 4-20mA or RS485 Modbus RTU signal receiving system before connecting
We use cookies to make the site work properly, to understand how it is used, and to show content that is relevant to you. You choose which types to allow; strictly necessary cookies are always on. Privacy Policy