Infrared Ceramic Heater INFRAPARA Model AWI-1 1000W (Infrared Ceramic Heater)
INFRAPARA AWI-1-1000W is an Infrared Ceramic Heater (Infrared Ceramic Heater) in the AWI-Series for industrial heating applications, using a ceramic plate as the heat distribution component and transmitting heat energy in the form of infrared radiation to the workpiece.
The AWI-1 heater has an electrical power of 1000W, operates at 220VAC, has a white ceramic heater body with dimensions 245 x 60 mm, comes with 4 connection wires, and includes an internal temperature sensor of the Thermocouple Type K.
The AWI-Series is a special model with heat insulation on the backside to help reduce heat loss from the back of the heater and improve heat transfer efficiency to the workpiece when the installation system is designed appropriately.
Suitable for automotive paint baking, metal paint baking, drying, and plastic forming, as well as machines that require infrared heat in the production process.
General Features (Features)
- Infrared Ceramic Heater, brand INFRAPARA
- Model AWI-1 in the AWI-Series
- Electrical power 1000W
- Voltage rating 220VAC
- Heater material is white ceramic
- Heater plate size 245 x 60 mm
- 4 connection wires
- Includes internal temperature sensor Thermocouple Type K
- Has heat insulation on the backside
- Provides heat via infrared radiation
- Delivers even heat to the workpiece when the installation is designed appropriately
- Suitable for paint baking, drying, and plastic forming
- Can be used with external temperature control systems that support Thermocouple Type K
Technical Specifications (Technical Specifications)
| Specifications |
Details |
| Brand |
INFRAPARA |
| Model |
AWI-1 |
| Full Model |
AWI-1-1000W AC220V 4wire White (With TC Type K) |
| Series |
AWI-Series |
| Product Type |
Infrared Ceramic Heater |
| Heater Type |
Ceramic Plate Infrared Heater |
| Rated Power |
1000 W |
| Rated Voltage |
220 VAC |
| Series Voltage Specification |
220 / 230 VAC |
| Rated Current |
4.5 A (SCMA Reference at 220 VAC) |
| Heating Material |
Ceramic |
| Color |
White |
| Heater Dimensions |
245 x 60 mm |
| Number of Wires |
4 Wires |
| Built-in Temperature Sensor |
Thermocouple Type K |
| Rear Thermal Insulation |
Yes |
| Heating Method |
Infrared Radiant Heating |
| Applications |
Paint Curing, Industrial Drying, Plastic Forming |
| Maximum Operating Temperature |
Refer to Manufacturer Specifications |
| Catalog Reference |
SCMA General Catalog Vol.5, C3-07 |
Infrared Radiant Heating
Ceramic plate infrared heaters convert electrical energy into heat and emit infrared radiation from the heater surface to transfer heat energy to the surface of the workpiece.
They can be used in processes such as paint curing, drying, or forming materials that require localized heating. The heating effect depends on the installation distance, number of heaters, surface temperature, workpiece material, and system design.
Rear Thermal Insulation
The AWI-Series is a model with thermal insulation on the back side of the heater plate, which helps reduce heat loss to the back side and improves the efficiency of the heating system design.
Installation must also allow for spacing from other equipment and flammable materials according to the manufacturer's specifications, as the heater and surrounding structure can reach high temperatures during operation.
Built-in Temperature Sensor (Thermocouple Type K)
The INFRAPARA AWI-1 heater comes with a Type K thermocouple for measuring the internal temperature of the heater, which can be used with a temperature controller that supports Type K sensors.
The temperature control system should include a power switching device, such as an SSR or contactor, properly selected in rating, along with an over-temperature protection system, to ensure safe and appropriate operation for the production process.
The total number of wires is 4, consisting of the power circuit and the temperature measurement circuit. However, before connecting, you must check the wire colors and connectors according to the actual product's wiring diagram. Do not assign wire functions based solely on color or number of wires.
Electric Power and Power Supply
The heater has a rated power of 1000W at 220VAC. According to the SCMA product data, the current is approximately 4.5A for operation at the rated power.
When installing multiple heaters in a machine, the total load should be calculated, and the wiring, protective devices, and switching equipment should be selected appropriately for the actual current usage, taking into account the installation area temperature.
Paint Curing and Drying
It is suitable for use in automotive paint curing, metal paint curing, and workpiece drying applications. The temperature, curing time, distance from the workpiece, and number of heaters should be appropriately set according to the properties of the materials and paints used.
For applications involving flammable vapors or explosive areas, the equipment and system should be selected and designed according to the safety requirements of the area. General-purpose heaters should not be used in such areas without proper evaluation and certification.
Plastic Thermoforming
The infrared ceramic heater can be used as a heat source for the plastic thermoforming process by transferring heat from the heater plate to increase the temperature of the plastic sheet before forming.
The position and number of heaters should be designed to ensure even temperature distribution according to the size and type of plastic, to avoid excessive heating in certain areas.
Applications
- Automotive Paint Curing Machine
- Metal Paint Curing Machine
- Industrial Workpiece Drying Machine
- Plastic Thermoforming Machine
- InfraRed Heating in Production Line
- Localized Workpiece Heating System
- Machines requiring heater temperature measurement with Type K Thermocouple
Installation Precautions
- Check the voltage rating before powering the heater
- Select the wire size and protective devices appropriate for the load current
- Use heat-resistant wires and connectors suitable for the installation temperature
- Check the power wires and thermocouple according to the manufacturer's manual before connecting the circuit
- Control the temperature with a device that supports Thermocouple Type K
- Provide a high-temperature protection system according to the machine's risk
- Install with a distance from flammable materials and non-heat-resistant parts
- Prevent contact with the heater surface during operation or after turning the machine off
- Avoid shocks that may cause the ceramic plate to crack
- Turn off the power supply and wait for the heater to cool down before maintenance
- Check the insulation and connecting wires before each use
Important Notes
- The product is an INFRAPARA infrared ceramic heater model AWI-1
- Electric power 1000W
- Voltage rating 220VAC
- White ceramic material
- Size 245 x 60 mm
- 4 wires connection with built-in Thermocouple Type K
- Special model with heat insulation on the back
- Check the installation size and mounting distance of the heater before ordering
- Check the wiring manual and appropriate control equipment before use