Toggle Nav
My Cart 0

APPLICATION EXAMPLES T201 AC/DC CURRENT TRANSDUCERS SENECA

Price on request – please contact us
Out of stock
SKU
050956
Out of stock

The price for this item is not shown online yet.

Ask for a price on LINE

KEPLER SCMA

KCTM-36 V, KEPLER, Split Core Current Transformer, KCTM-36V Series, 600A/333mV, 600A Current Transformer, 333mV AC Output, Split Core CT, Split Type Current Transformer, Voltage Output CT, AC Current Sensor, 50/60Hz Current Transformer, Class 0.5, Current Measurement, Electrical Monitoring, Energy Monitoring, Power Monitoring, Industrial Electrical Measurement, Current transformer, Split core current transformer, KEPLER split core current transformer

*Price does not include VAT

KEPLER KCTM-36 V Split Core Current Transformer

KEPLER KCTM-36 V Split Core Current Transformer is a detachable core (Split Core CT) current transformer for measuring alternating current in electrical systems. It has a primary rated current of 600A and an output voltage rating of 333mV AC, suitable for use with electricity metering devices and current measurement equipment that support a 333mV AC input.

The split core design allows the transformer's core to be opened and closed to install around electrical conductors without needing to disconnect existing wire ends from their connections. This increases installation convenience for current measurement systems, although power sources should be disconnected and safety measures followed before installation.

KEPLER KCTM-36 V belongs to the KCTM-36V Series, which is a 333mV AC output voltage type current transformer, differing from the KCTM-36 model with a 5A output current. Therefore, appropriate signal receiving equipment and current rating settings must be selected according to the CT type.

General Features

  • Brand: KEPLER
  • Product Model: KCTM-36 V
  • Product Type: Split Core Current Transformer
  • Detachable core current transformer, can open the core to install around electrical conductors
  • Rated primary current: 600A AC
  • Rated output voltage: 333mV AC
  • Precision: Class 0.5 according to series data
  • Supports power frequency: 50-60Hz
  • Housing made of PC / UL94-V0 material
  • Suitable for current measurement and electricity consumption monitoring systems

Technical Specifications (Technical Specifications)

BrandKEPLER
ModelKCTM-36 V
Product SeriesKCTM-36V Series
Product TypeSplit Core Current Transformer
Rated Primary Current600A AC
Rated Output333mV AC
Accuracy ClassClass 0.5 (Series Reference)
Accuracy Range20% to 120% of Rated Current (Series Reference)
Frequency50-60Hz
Phase AngleLess than 2 degrees at 50% of rated current (Series Reference) Insulation Voltage600VAC (Series Reference) Maximum Primary Voltage5000VAC, Insulated Conductor (Series Reference) Dielectric Strength2.5kV / 1mA / 1min (Series Reference) Operating Temperature-15 to +60°C Operating HumidityLess than 85% RH Case MaterialPC / UL94-V0 Bobbin MaterialPBT Core MaterialPermalloy Internal StructureEpoxy Lead WireUL1015, Twisted Pair, 22 AWG (Series Reference) Compatible Measurement Input333mV AC CT Input

How It Works

A split core current transformer operates based on the principle of electromagnetic induction. When alternating current flows through a conductor within the CT core, it generates a magnetic field that induces an electrical signal in the secondary winding.

The KEPLER KCTM-36 V with a rating of 600A/333mV is designed to have an output voltage rating of 333mV AC when the primary current equals 600A AC. The output signal varies proportionally with the measured current under conditions specified by the manufacturer.

The 333mV AC output voltage can be used in conjunction with measuring devices that support CT output voltage, provided that the CT rating is set to match 600A/333mV on the receiving device for accurate current measurement.

Installation and Usage

  • Select the alternating current conductor where you want to measure the current.
  • Disconnect power supply and ensure there is no voltage before installation.
  • Open the split core and install it around a single wire of the circuit that needs measurement.
  • Cover the CT core completely according to the locking mechanism of the device.
  • Connect the signal wires to a meter supporting 333mV AC CT input.
  • Set the CT rating in the measuring device to match 600A/333mV.
  • Check the installation direction and signal polarity from the manufacturer's documentation
  • Ensure that the CT core channel size is appropriate for the wire or bus bar size
  • Examples and Usage Guidelines

    • Measure electrical current in control panels and distribution boards
    • Use with Energy Monitoring systems supporting 333mV CT input
    • Monitor load currents of machinery and industrial equipment
    • Apply in building energy consumption monitoring systems
    • Use for current measurement applications requiring open-CT installation

    Considerations

    • This model is a 333mV AC output CT, not a 5A output CT
    • Meters or measuring devices supporting 333mV AC CT input must be used in conjunction with it
    • Verify the current rating and measurement range to match actual usage requirements
    • For general load current measurements, encircle only one conductor with the CT, not both phase and neutral wires together
    • Check the CT core channel size and installation space before selecting for use
    • Configure CT Rating settings and signal polarity prior to operation
    • Avoid using 333mV CTs as direct replacements for 5A CTs
    • Some technical data references KCTM-36V Series; consult specific model documentation before installation
    • Installation in electrical systems must be carried out by qualified personnel following safety measures