SIGMATEK AO 026 (S-DIAS Analog Output Module)
SIGMATEK AO 026 is an analog output module (Analog Output Module) in the S-DIAS family for industrial automation control systems. It supports sending two analog signals, and can choose between current (Current) or voltage (Voltage) signal types according to system requirements.
The module has a 16-bit output resolution, suitable for applications requiring continuous control signals from PLCs or automation systems to external devices that support them.
The unit is compact in size at 12.5 x 104 x 72 mm (width x height x depth) and can be designed into installations compatible with SIGMATEK's S-DIAS system.
General Features
- Brand: SIGMATEK
- Model: AO 026
- Series: S-DIAS
- Type: S-DIAS Analog Output Module
- Supports two analog output channels
- Can choose between current or voltage signal types for the output
- Has a 16-bit output resolution
- Unit size is 12.5 x 104 x 72 mm
- Suitable for sending analog control signals in industrial systems
- Works with compatible S-DIAS control systems
- Suitable for factory automation and machine control systems
Technical Specifications
| Specifications |
Details |
| Brand | SIGMATEK |
| Model | AO 026 |
| Series | S-DIAS |
| Product Type | Analog Output Module |
| Number of Analog Outputs | 2 Channels |
| Output Signal Type | Current / Voltage |
| Output Resolution | 16 bit |
| Voltage Output Range | To Be Confirmed from Manufacturer Datasheet |
| Current Output Range | To Be Confirmed from Manufacturer Datasheet |
| Output Accuracy | Not Specified in Catalog |
| Maximum Output Load | Not Specified in Catalog |
| Electrical Isolation | Not Specified in Catalog |
| Module Power Requirements | To Be Confirmed According to S-DIAS System |
| Width | 12.5 mm |
| Height | 104 mm |
| Depth | 72 mm |
| Dimensions (W x H x D) | 12.5 x 104 x 72 mm |
| Operating Temperature | Not Specified in Catalog |
| Catalog Reference | SCMA General Catalog Vol.5, D1-09 |
Note: The catalog confirms the number of output channels, signal type, resolution, and dimensions but does not clearly specify supported voltage or current ranges. Therefore, it is necessary to check the specific model datasheet before system design.
Analog Output Channels x2
The SIGMATEK AO 026 has two analog output channels for sending control signals from automation systems to devices that accept commands via analog signals.
It can be applied in controlling devices that support voltage or current signals, such as drive units, power control circuits, or process control equipment. Compatibility of the signal must be verified before connecting.
Voltage and Current Output Support (Voltage / Current Output)
The AO 026 supports two types of output signals: Voltage Output and Current Output according to the catalog information.
Voltage Output: Used for sending control signals in voltage form to devices that support it. The actual operating voltage range must be verified from the datasheet.
Current Output: Used for sending control signals in current form to devices that support it. The actual operating current range and load rating must be verified from the datasheet.
The AO 026 should not be specified as supporting specific voltage or current ranges until information is received from the manufacturer.
16-bit Output Resolution
The AO 026 has a 16-bit output resolution according to catalog data, allowing for setting multiple levels of analog signal within the supported module range.
16-bit resolution is a feature of the digital-to-analog conversion, not the direct accuracy of the signal itself. The actual accuracy depends on the output circuitry, load, and operating environment.
S-DIAS System Compatibility
The AO 026 is an S-DIAS module from SIGMATEK for expanding Analog Output channels in supported automatic control systems. A suitable CPU, power supply, and accessories must be selected accordingly.
Configuration settings, module compatibility, and system controls should be verified according to the manufacturer's manual before installation.
Dimensions (Mechanical Dimensions)
| Dimension |
Size |
| Width | 12.5 mm |
| Height | 104 mm |
| Depth | 72 mm |
Applications Examples (Applications)
- Analog control signal transmission systems in industrial machinery
- Control systems for devices that accept voltage or current commands
- Production process control systems
- Motor drive operation systems supporting analog signals
- Power control systems accepting analog commands
- Factory Automation and Machine Control Systems
- Analog Output expansion for PLCs supporting S-DIAS
- Design and development of industrial control systems
SIGMATEK AO 026 Selection Guidelines
- Check the number of Analog Output channels required
- Determine whether the end device requires voltage or current signals
- Verify supported output signal range from the Datasheet
- Evaluate load ratings and drive capability
- Consider 16-bit resolution according to system requirements
- Check accuracy and response time of the output
- Ensure compatibility with CPU and S-DIAS system
- Verify power supply and wiring configuration
Installation Precautions
- Confirm signal type (Voltage or Current) before connecting
- Use specific model Datasheet for output signal range
- Check terminal connections and manufacturer's Wiring Diagram
- Avoid overloading the output beyond its capability
Separate the analog signal lines from power lines that have interference as appropriate
Check grounding and shield connections according to system requirements
Verify output configuration before actual use
Do not plug or unplug modules while powered on, unless the manufacturer's manual specifies support for it
Test each output signal channel before using it to control machinery
Important Notes Before Purchase (Important Notes)
- The product is a SIGMATEK S-DIAS Analog Output Module model AO 026
- Supports 2 analog output channels
- Can choose between Current or Voltage output types
- Has an output resolution of 16 bit
- Dimensions: 12.5 x 104 x 72 mm
- This is not the Analog Input Module model AI 026
- The catalog does not clearly specify the voltage and current output ranges
- Must check signal range and load coordinates from the Datasheet before use
- Check CPU and S-DIAS system compatibility before purchasing